Beckett CG10 manual Burner Configurations, Low Rate Burner Configuration 300 to 800 MBH Applications

Page 29

Section: Burner Configurations

Burner Configurations

The CG10 burner is offered in configurations that allow it to be customized to the capacity and furnace size needs of many different appliances. Two blower wheel sizes provide airflow capacity through the range. An air guide provides static pressure augmentation at low rates and an inlet sleeve maximizes flow capacity at high rates. Three air tube shrouds shape and stabilize the base of the flame. Twelve gun assemblies provide mixing control and retain the flame. See chart on opposite page.

Low Rate Burner Configuration; 300 to 800 MBH Applications

High Rate Burner Configuration; 600 to 1200 MBH Applications

CG10 Burner Manual

29

Image 29
Contents Fire, Explosion and Asphyxiation Hazards Contents Hazard Definitions General InformationOwner’s Responsibility Follow these instructions exactly To the OwnerAgency Approvals Special Requirements When contacting Beckett forExactly Indoor Installation Protect against Dust Moisture Pre-installation ChecklistClearances Test For Gas Pipe LeaksVerify firing input range Fuel gas supplyMBH Verify burner air tube assemblyBurner Model Airtube Dim. a Dim. B Burner DimensionsConnect Gas Piping Mount the BurnerProtect the Air Tube from Overheating Do Not Use Teflon Tape on Gas PipingGas Trains Gas Leaks and Exposion Hazards Install a Drip Leg in Gas Supply PipingGas supply piping capacity Pipe Length ftUL gas train configuration Keep Service Access Covers Securely Installed Wire the BurnerDo Not Bypass Safety Controls Electrical Shock HazardDelayed Ignition, Explosion Fire Hazards Professional Installation Service RequiredSequence of Operation Prepare the Burner for Start-upGas Supply Piping GeneralElectrical Boiler or ApplianceMajor Components Item Description CG10 component familiarizationVerify input firing rate Burner start procedureStart the Burner Shutter and Band Initial burner settingsEstimating Rate Temperature correctionClocking a gas meter Uncorrected flow rateCG10.6S CG10.5S CG10.4S CG10.3S CG10.2S CG10.1S Flame safeguard safety lockout Simulate a Recommended combustion test sequence Use test instruments to set combustionAnnual Professional Service Required Maintenance and ServiceAnnual maintenance Turn Off Electric and Gas Supply Before ServicingFlame safeguard Adjust the burner for proper combustionInstallation area Ignition Reliability Manual shutdown for long periodsGas Gun Assembly Propane Restrictor Description InstallationPropane Restrictors Replacement Part NumbersTest/Inspection Frequency Comments Inspect Heating System RegularlyPeriodic Inspection Sheet See Table Replacement PartsHigh Rate Burner Configuration 600 to 1200 MBH Applications Burner ConfigurationsLow Rate Burner Configuration 300 to 800 MBH Applications Air Platform Blower Wheel Air Inlet Gas Gun Nominal Assembly Capacity, MBHBurner Model ShroudCG10 Burner Manual Limited Warranty Information
Related manuals
Manual 2 pages 33.71 Kb

CG10 specifications

The Beckett CG10 is a premium gas furnace that stands out in today's competitive heating market due to its innovative technology and reliable performance. Designed with efficiency and comfort in mind, the CG10 model ensures optimal heating solutions for residential spaces.

One of the most significant features of the Beckett CG10 is its impressive Annual Fuel Utilization Efficiency (AFUE) rating. With ratings often exceeding 90%, this furnace significantly reduces energy consumption and ensures cost-effective heating. This high-efficiency rating translates to lower utility bills and less environmental impact, making it a smart choice for eco-conscious homeowners.

The CG10 utilizes advanced combustion technology to ensure that fuel is burned effectively, maximizing heat generation while minimizing emissions. This innovative technology not only enhances the furnace's performance but also contributes to cleaner air, aligning with modern environmental standards.

A notable characteristic of the Beckett CG10 is its quiet operation. The unit is designed to operate with minimal noise, ensuring a comfortable living environment without disruptive sounds. This is particularly important for families and individuals who prioritize tranquility in their homes.

The furnace is built with durable materials, ensuring longevity and reliable performance over the years. Its construction adheres to strict industry standards, making the CG10 both robust and dependable. Regular maintenance is simplified thanks to its user-friendly design, which allows homeowners to access critical components easily.

Safety is a paramount concern in any heating system, and the Beckett CG10 does not disappoint. It comes equipped with multiple safety features, including flame sensors and safety shut-off mechanisms, ensuring peace of mind for users.

Additionally, the Beckett CG10 can be integrated with smart home technology, allowing homeowners to monitor and control their heating system remotely. This capability enhances convenience and provides further energy savings, as users can adjust their heating preferences from anywhere.

In summary, the Beckett CG10 gas furnace presents an ideal solution for homeowners seeking a blend of efficiency, durability, and advanced technology in their heating systems. Its high AFUE rating, quiet operation, and safety features make it a top choice for those prioritizing comfort and environmental responsibility.