Beckett 120 Vac/60 Hz instruction manual Prepare burner

Page 5

Instruction Manual – Model AFG Oil Burner

Prepare burner & site

Prepare burner

Low firing rate baffle

The AFG Low Firing Rate Baffle (LFRB), item 7, page 11, reduces the air flow (cfm). The LFRB is sometimes used for firing rates under 1.00 GPH as listed in the table below. Refer to the appliance manufacturer’s instructions or the Beckett OEM Specification Guide part number 6711. Do not omit the LFRB when specified. Omitting the baffle when specified or installing the baffle when not specified could result in poor burner performance.

Burner fuel unit

Verify that the burner fuel unit is compatible with the oil supply system. For more details, refer to “￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿￿” on page 8.

Attach air tube (if not already installed)

If using a flange and gasket, slide them onto the air tube. Then attach the air tube to the burner chassis using the four sheet metal screws provided. See Figure 2 on page 6 for details.

Prepare burner (continued)

Install burner nozzle (if not already installed) (continued)

Use care when removing and installing oil nozzles:

Inspect the nozzle adapter before installing nozzle. If it is grooved or scratched on the sealing surface, replace the nozzle line assembly. Otherwise, oil could leak at the nozzle-adapter joint, causing serious combustion problems.

Protect the nozzle orifice and strainer when installing. If the orifice gets dirt in it or is scratched, the nozzle will not function properly.

Do not over-torque the nozzle when installing. This will cause deep grooves in the nozzle adapter, preventing a seal when a new nozzle is installed.

Use a wrench or vise to hold the nozzle adapter. ￿￿￿￿￿￿attempt to remove or replace nozzle without holding adapter. The nozzle alignment could be seriously damaged. Use a nozzle wrench that secures the adapter or use 3/4" and 5/8" open-end wrenches.

Do not squeeze the electrodes too tightly when handling the nozzle line assembly. This could change the electrode tip settings or damage the ceramic electrode insulators.

Carefully check and realign electrode tips after replacing nozzle, ensuring the electrode settings comply with Figure 1.

Install burner nozzle (if not already installed)

Make certain the nozzle is selected for the fuel unit pressure used. For applications with fuel unit pressure above 100 psig, the nozzle rated capac- ity will be less than the appliance firing rate. Use only the specified spray pat- tern unless combustion test results indicate the need for a change. Failure to use the correct nozzle size and type can result in unacceptable combustion, possibly causing severe personal injury, death or substantial property damage.

1.Remove the plastic plug protecting the nozzle adapter threads.

2.Place a ³⁄₄" open-end wrench on the nozzle adapter. Insert the nozzle into the adapter and finger tighten. Finish tightening with a ⁵⁄₈" open- end wrench. Use care to avoid bending the burner head support legs or electrodes. See ￿￿￿￿￿￿￿, above right.

3.If you remove the head to replace the nozzle (type “L1” or “V1” heads), carefully reconnect the head to the nozzle adapter, making sure to butt the head support to the nozzle adapter shoulder (see Figures 3 and 4, page 7).

If the nozzle is already installed, remove the nozzle line assembly to verify that the nozzle size and spray pattern are correct for the application (per appliance manufacturer’s information or Beckett OEM Specification Guide, part number 6711. Verify that the electrode tip settings comply with Figure 1.

If the nozzle is not installed, obtain a nozzle of the manufacturer, capacity and spray angle specified in appliance manufacturer’s information or Beckett OEM Specification Guide, part number 6711. For conversions or upgrades, when in- formation is not available for the application:

1.Refer to table below to select the mid-range nozzle spray angle for the head type being used.

2.Fire the burner and make sure the combustion is acceptable and the flame is not impinging on chamber surfaces.

3.If a shorter flame is needed, select a wider spray angle. If a longer flame is needed, select a narrower spray angle.

4.Either hollow or solid spray patterns may be used. If combustion results are not satisfactory with the selected spray pattern, try the other pattern.

Check/adjust electrodes

Check the electrode tip settings. Adjust if necessary to comply with the dimen- sions shown in Figure 1. To adjust, loosen the electrode clamp screw and slide/ rotate electrodes as necessary. Securely tighten the clamp screw when finished.

Figure 1 — Electrode settings

Servicing nozzle line assembly

1.Turn off power to burner before proceeding.

2.Disconnect oil connector tube from nozzle line.

3.Loosen the two screws securing igniter retaining clips and rotate both clips to release igniter baseplate. Then tilt igniter back on its hinge.

4.Remove splined nut.

5.￿” head air tubes

Remove nozzle line assembly from burner, being careful not to damage the electrodes or insulators while handling. To ease removal of long assemblies (over 9 inches), rotate assembly 180° from installed position after pulling partially out of tube.

6.￿￿” and “￿￿” head air tubes

Slide nozzle line assembly forward (further into air tube) so the head clears the venturi opening. Then rotate the nozzle line assembly 90° so the nozzle line end points up. Pull the nozzle line assembly toward you and remove assembly from burner.

7.To replace the nozzle assembly, reverse the above steps.

5

Image 5
Contents Motor voltage 120 Vac / 60 Hz AFG OilPerform annual maintenance To replace the blower wheel Inspect/prepare installation siteOwner’s information and warranty Mount burner on applianceVerify specifications Be aware of hazard definitions Direct air supply and sidewall venting Chimney or vent Clearances to burner and applianceCombustion air supply Outside air kit applicationsPrepare burner Beckett T500 gauge may also be used Check/adjust Z dimension F headDimensions for Figures 2, 3 Starting adjusting plate settings with V1 head L1 heads see and for dimensionsMount burner on appliance Connect fuel lines Wire burnerR7184 primary control features Power before servicingStartup burner/set combustion Perform annual maintenanceTo replace blower wheel Let burner run for approximately 5 to 10 minutesAwaiting New info Replacement partsWarranty Owner’s information Owner service and maintenanceAnnually minimum Daily

120 Vac/60 Hz specifications

The Beckett 120 Vac/60 Hz is a versatile and reliable solution designed for a variety of heating applications. This model exemplifies a combination of efficiency, user-friendliness, and advanced technology, making it a popular choice for both residential and commercial heating needs.

One of the standout features of the Beckett 120 Vac/60 Hz unit is its exceptional energy efficiency. Designed to minimize energy consumption while maximizing heat output, it incorporates modern technology that helps reduce operating costs. The unit is built with a continuously adjustable firing rate, allowing it to operate at the optimal heating level for varying demand. This not only improves efficiency but also ensures consistent temperature control throughout the space.

Another significant characteristic of the Beckett model is its robust construction. Made from high-quality materials, the unit is designed to withstand the rigors of daily use while maintaining reliable performance. The design also includes features that reduce wear and tear, increasing its longevity and reliability.

Safety is paramount with the Beckett 120 Vac/60 Hz. It comes equipped with multiple safety features, including automatic shut-off mechanisms and overheating protection. This ensures both user safety and peace of mind, making it ideal for families and businesses alike.

The advanced technology used in this model includes a sophisticated control system that allows for precise monitoring and adjustments. Users benefit from intuitive interfaces that provide real-time information about system performance, enabling easy troubleshooting and maintenance.

The Beckett unit also boasts quiet operation, making it suitable for environments where noise reduction is essential. Its compact design allows for flexibility in installation, whether it be in a tight utility room or a more spacious area.

Furthermore, the Beckett 120 Vac/60 Hz supports a range of fuel types, enhancing its versatility. Whether you are using oil, gas, or other alternatives, this unit is equipped to operate efficiently with minimal adjustments.

In summary, the Beckett 120 Vac/60 Hz combines exceptional efficiency, safety features, and advanced technology into a compact and robust heating solution. Its versatility and user-friendly design make it an excellent choice for a variety of applications, offering peace of mind and comfort to both homeowners and businesses.