Beckett 120 Vac/60 Hz Check/adjust Z dimension F head, Dimensions for Figures 2, 3

Page 6

Instruction Manual – Model AFG Oil Burner

Prepare burner & site

Check/adjust "Z" dimension - "F" head

Figure 2 — “F” heads (plus burner detail for all head styles) (see Table 3 for dimensions)

1. See Figure 2 above.￿The important "Z" dimension is the distance from the

Table 3

Dimensions for Figures 2, 3 and 4

face of the nozzle to the flat face of the head (or heat shield, if applicable).

 

 

 

 

This distance for F heads is 1 ¹⁄₈" (1 ³⁄₈" if the air tube has a heat shield).

 

 

 

 

 

 

 

 

The "Z" dimension is factory set for burners shipped with the air tube in-

 

 

 

 

stalled.￿Even if factory set, verify that the "Z" dimension has not been changed.

 

 

 

 

 

 

 

 

2. Use the following procedure to adjust the "Z" dimension, if it is not correct:

• Turn off power to the burner.

Disconnect the oil connector tube from the nozzle line.

• See Figure 2.￿Loosen the splined nut from the nozzle line.￿Loosen the hex head screw securing the escutcheon plate to the burner housing.

• Place the end of a ruler at the face of the nozzle and, using a straight edge across the head, measure the distance to the face of the head.￿(A

￿Beckett T500 gauge may also be used.)

Slide the nozzle line forward or back until this dimension for F heads is 1¹⁄₈" (1³⁄₈" to the face of the heat shield, if applicable).

• Tighten the hex head screw to secure the escutcheon plate to the burner chassis.￿Then tighten the splined nut and attach the oil connector tube.

3. Recheck the "Z" dimension periodically when servicing to ensure the es- cutcheon plate has not been moved.￿You will need to reset the "Z" dimen- sion if you replace the air tube or nozzle line assembly.

The Beckett Z ￿￿￿￿￿(part number Z-2000) is available to permit checking the ￿head "Z"￿dimension without removing the burner from the appli- ance.

6

Image 6
Contents AFG Oil Motor voltage 120 Vac / 60 HzOwner’s information and warranty Inspect/prepare installation sitePerform annual maintenance To replace the blower wheel Mount burner on applianceVerify specifications Be aware of hazard definitions Combustion air supply Chimney or vent Clearances to burner and applianceDirect air supply and sidewall venting Outside air kit applicationsPrepare burner Check/adjust Z dimension F head Dimensions for Figures 2, 3Beckett T500 gauge may also be used L1 heads see and for dimensions Starting adjusting plate settings with V1 headWire burner Mount burner on appliance Connect fuel linesPower before servicing R7184 primary control featuresTo replace blower wheel Perform annual maintenanceStartup burner/set combustion Let burner run for approximately 5 to 10 minutesReplacement parts Awaiting New infoAnnually minimum Owner’s information Owner service and maintenanceWarranty Daily

120 Vac/60 Hz specifications

The Beckett 120 Vac/60 Hz is a versatile and reliable solution designed for a variety of heating applications. This model exemplifies a combination of efficiency, user-friendliness, and advanced technology, making it a popular choice for both residential and commercial heating needs.

One of the standout features of the Beckett 120 Vac/60 Hz unit is its exceptional energy efficiency. Designed to minimize energy consumption while maximizing heat output, it incorporates modern technology that helps reduce operating costs. The unit is built with a continuously adjustable firing rate, allowing it to operate at the optimal heating level for varying demand. This not only improves efficiency but also ensures consistent temperature control throughout the space.

Another significant characteristic of the Beckett model is its robust construction. Made from high-quality materials, the unit is designed to withstand the rigors of daily use while maintaining reliable performance. The design also includes features that reduce wear and tear, increasing its longevity and reliability.

Safety is paramount with the Beckett 120 Vac/60 Hz. It comes equipped with multiple safety features, including automatic shut-off mechanisms and overheating protection. This ensures both user safety and peace of mind, making it ideal for families and businesses alike.

The advanced technology used in this model includes a sophisticated control system that allows for precise monitoring and adjustments. Users benefit from intuitive interfaces that provide real-time information about system performance, enabling easy troubleshooting and maintenance.

The Beckett unit also boasts quiet operation, making it suitable for environments where noise reduction is essential. Its compact design allows for flexibility in installation, whether it be in a tight utility room or a more spacious area.

Furthermore, the Beckett 120 Vac/60 Hz supports a range of fuel types, enhancing its versatility. Whether you are using oil, gas, or other alternatives, this unit is equipped to operate efficiently with minimal adjustments.

In summary, the Beckett 120 Vac/60 Hz combines exceptional efficiency, safety features, and advanced technology into a compact and robust heating solution. Its versatility and user-friendly design make it an excellent choice for a variety of applications, offering peace of mind and comfort to both homeowners and businesses.