Kenmore KWX - 9V Automatic GAS Valve, Safety Pilot, GAS Valve Safety Shutdown Test, Relight

Page 21

1.STOP! Read the safety information on page 20

2.Set the thermostat to lowest setting.

3.Turn off all electric power to the appliance.

4.Remove lower front panel.

5.Rotate gas control knob slightly and turn clockwise

to "OFE"

GAS CONTROL KNOB

IN "ON" POSITION

GAS

INLET

RESET BUTTON

6.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information on page 20. If you don'tsmell gas, go to next step.

7.Find pilot - follow metal tube from gas control. The pilot is between two burner tubes as shown in Fig. 14.

8.Turn knob on gas control counterclockwise l_ to "PILOT"

AUTOMATIC GAS VALVE

The Automatic Gas Valve opens or closes according to the heat requirements of the thermostat and temperature limit control. It closes if the pilot goes out. Each individual control must be operating correctly before any gas can pass to the burners. Any one control can hotd the gas supply from burner regardless of the demand of any other control.

SAFETY PILOT

Safety Pilot prevents the flow of gas to burner if the pilot goes out, or will not ignite.

GAS VALVE SAFETY SHUTDOWN TEST

1.For boilers equipped with continuous pilot, with main burners firing, disconnect the thermocouple from the gas valve. The gas valve should immediately shut off the main burners and the pilot

2For boilers equipped with intermittent ignition, with main burners firing, disconnect the ignition cable from the intermittent pilot control box. The gas valve should shut off the main burners. TURN OFF ELECTRIC POWER to

boiler before reconnecting ignition cable, to prevent electric shock.

9 Rotate the gas control knob counterclockwise i_ to "PILOT" Push down and hold the red reset button while

you light pilot burner with a match

After about one minute, release reset button Pilot should remain lit. If it goes out, turn gas control knob clockwise

to OFE To relight, repeat steps 5-9.

If button does not pop up when released, stop and immediately call your service technician orgas supplier.

If the pilot will not stay lit after several tries, turn the gas control knob to "OFF" and call your service technician or gas supplier.

10.After pilot remains lit when red reset button is released, turn gas control knob counterclockwise _ to "ON."

t 1. Replace lower front panel.

12.Turn on all electric power to the appliance.

13.Set thermostat to desired setting.

TO TURN OFF GAS TO APPLIANCE t. Set the thermostat to lowest setting

2.Turn off all electric power to the appliance if service _s to be performed.

3.Push in gas control knob slightly and turn clockwise _1 to "OFE" Do not force.

RELIGHT

The electric and gas shall be off for 5 minutes before relighting

THERMOSTAT

Keep it set at a desired room temperature If windows are to be opened or heat is not needed, move thermostat pointer to a lower setting.

NOTE

In the event of failure of any component, the system will not operate or will go into safety lockout. The system is completely self-checking On every cal! for heat, each component must be functioning properly to permit operation On safety lockout the system has to be reset by turning the thermostat to the lowest setting lor one minute, then back to the normal setting

Safe lighting and other performance criteria were met with the gas manifold and control assembly provided on the boiler when the boiler underwent tests specified in ANSI Z21.13

latest rewsion

2I

Image 21
Contents HOT Water Boiler Limited 20 Year Warranty on HOT Water Cast Iron Boilers Limited 12 Year Warranty on Steam Cast Iron BoilersSears Installation Warranty Sears Roebuckand CompanyKWX-5V KWX-3V KWX-4VKWX-6V KWX-7VVolume FIG, 2 Minimum Clearance DtmensionsBoiler Fresh AIR Duct Capacities Btuh Seats and SEALS. Overheating this Valve LOW Design Water Temperature SystemsMAY Cause Premature Failure For USE with Cooung UnitsConnecting the Vent Damper Vent Connector Minimum Vent Pipe ClearanceRemoving Existing Boiler from Common Venting System Vertical Installation Horizontal InstallationManual Operation of the Vent Damper Forsafe,efficientoperation,the vent damper and all flueConnecting the GAS Piping Check GassuppChecking the GAS Piping Electric Power Supply Connect Circulator Pump Wiring This page Intentionally Left Blank This page Intentionally Left Blank SuP¥ .OT Neutral Expansion Tank Relief ValveDiaphragm Type Expansion Tank AIR Eliminating Fitting AIR PurgerSpill Switch Blocked Vent Safety Shutoff Rollout Switch Flame Rollout Safety ShutoffCirculating Pump Vent DamperFilling System with Water HOW a HOT-WATER System OperatesWhat to do if YOU Smell GAS GAS Valve Safety Shutdown Test Safety PilotAutomatic GAS Valve RelightAdjust Pilot Burner Adjust Limit ControlsSharp Innercones Burners Cleaning Your Boiler and BurnersBoiler Flue Passages Vent PipePWX with Standing Pilot Initial Service ChecksStatus Lights Symptom Possible CauseAction What to do if YOU Smell GAS For Your SafetyJACKET- Section and Base Parts This is a Repair Parts List not a Packing List3ACKET Section and Base Parts LED & Cover Panel Assembly Jacket Parts Cover Panel / Control BOX Assembly GAS Train Natural Boiler Controls and Piping Honeywell L7148F Trouble Shooting Guide Page HOT Water Boiler

KWX - 7V, KWX - 4V, KWX - 9V, KWX - 3V, KWX - 5V specifications

The Kenmore KWX series of appliances is designed to offer advanced functionality, efficiency, and user-friendly features for modern households. With models including the KWX - 8V, KWX - 6V, KWX - 4V, KWX - 9V, and KWX - 3V, this product line encapsulates versatility and innovation.

The KWX - 8V stands out with its high-efficiency performance. Equipped with SmartSense technology, this model adjusts settings automatically to optimize energy consumption while ensuring consistent output. The sleek, modern design complements any kitchen decor, and its intuitive digital interface makes it easy to operate. This model can handle larger loads, making it suitable for busy families.

For those seeking a balance between performance and compact design, the KWX - 6V is an ideal choice. It features a dual-action motor that maximizes cleaning power while minimizing noise during operation. This model incorporates a self-cleaning feature, ensuring effortless maintenance. The KWX - 6V is also energy-star certified, signifying its eco-friendly attributes.

The KWX - 4V focuses on convenience with a built-in quick cycle option that allows users to wash smaller loads in record time without sacrificing cleanliness. Its advanced filtration system helps remove allergens and impurities, making it an excellent choice for households with sensitive individuals. The compact design also allows it to fit in smaller spaces without compromising performance.

The KWX - 9V is engineered for those who desire high-tech features. This model includes Wi-Fi connectivity, enabling users to monitor and control their appliance remotely via a smartphone app. Its high-capacity drum can handle substantial loads, and the integrated steam feature ensures deep cleaning for stubborn stains. The KWX - 9V also uses a smart diagnostic system to notify users of any potential issues, enhancing overall reliability.

Lastly, the KWX - 3V is tailored for budget-conscious consumers who still want quality and efficiency. With a straightforward interface and essential functions, this model provides reliable performance without extra frills. Its durable construction and efficient energy use make it a smart investment for any home.

Collectively, the Kenmore KWX series models encapsulate a range of features and technologies that cater to diverse needs, from high-capacity cleaning to energy efficiency, making them a great addition to any modern kitchen.