While the oil burner is adjusted at the factory, it is re- |
|
|
|
commended that the operating characteristics of the |
|
|
|
burner be determined at |
|
|
|
necessary. Run the unit long enough at the burner |
|
|
|
maximum firing rate to make sure the burner has |
|
|
|
reached a stable maximum operating temperature. | 7 |
|
|
THEN, check the burner and adjust as follows: |
|
| |
Check to determine that the smoke spot number | 6 |
|
|
does not exceed 0.5 with a Bacharach control. Ad- |
|
|
|
just the burner as required to achieve this maximum. | M |
|
|
Check to determine that the CO2 rate is from 12 - 13 |
|
|
|
percent and that there is no CO production. Adjust |
|
|
|
the burner as required to achieve this operating cha- |
|
|
|
racteristic. |
|
|
|
Measure the temperature of the flue gas exiting the |
|
|
|
unit to determine that it does not exceed 250 de- |
|
|
|
grees F (120 C). | 7 |
|
|
Combustion inspection can be carried out on the | N | M | 6 |
| |||
|
|
| |
unit through the hole (item N) provided in the inspec- |
|
|
|
tion port (item 7). Be sure to replace the washer |
|
|
|
(item M) and the test point screw (item 6) properly |
|
|
|
after inspection. |
|
|
|
&+(&.,1*7+(6$)(7<'(9,&(6
At the time of
-Thermostats :
•Check to see that the thermostat bulbs are correctly positioned in their housings. This is essential to provide temperature sensing to facilitate burner
-Flame monitoring :
•Check to make sure that the burner shuts down properly upon the deactivation or discon- nection of the flame monitoring device or inter- ruption of the flow of fuel,
-Safety Pressure Relief valve :
•Check the safety pressure relief valve in the heating circuit for proper operation.