Heat & Glo LifeStyle GRAND-XTS Installing Adaptor and Termination Cap, Factory Built Wood Burning

Page 13

D. Installing Adaptor and Termination Cap

For installation of termination cap see minimum vent heights for various pitched roofs (see Figure 7.2) .

To install adaptor see Figure 7.3.

HORIZONTAL

OVERHANG

CAUTION

Sharp Edges

Wear protective gloves and safety glasses during installation.

Damper Flashing Kit (Optional)

2FT.

MIN.

GAS DIRECT VENT

TERMINATION CAP

20 INCHES MIN.

VERTICAL

LOWEST

WALL

 

DISCHARGE

 

OPENING

 

X

12

ROOF PITCH

IS X/ 12

H (MIN.) - MINIMUM HEIGHT FROM ROOF TO LOWEST DISCHARGE OPENING

For use with LINK-DV4-30B Liner Kit.

Note: Damper may have to be removed to use this kit.

Run flex liners through 3” holes in damper flashing.

Attach damper flashing to firebox roof with self tapping screws included in kit.

CLASS A PIPE

Roof Pitch

H (Min.) Ft.

Flat to 6/12

....................

1.0*

Over 6/12 to 7/12

1.25*

Over 7/12 to 8/12

1.5*

Over 8/12 to 9/12

2.0*

Over 9/12 to 10/12

2.5*

Over 10/12 to 11/12

3.25

Roof Pitch

H (Min.) Ft.

Over 11/12 to 12/12

4.0

Over 12/12 to 14/12

5.0

Over 14/12 to 16/12

6.0

Over 16/12 to 18/12

7.0

Over 18/12 to 20/12

7.5

Over 20/12 to 21/12

8.0

* 3 foot minimum in snow regions

Figure 7.2 Minimum Height from Roof to Lowest Discharge Opening

Figure 7.3

To help eliminate cold air drafts, it may be necessary to place non- combustible insulation around the flues as they go though the damper.

Note: The LINK-DV4-30B

system REQUIRES this insulation.

Masonry LINK-DV30B

LINK-DV4-30B

Installation

Installation

TERMINATION

CAP

EXHAUST

AIR

VENT PIPE

ÍORÎ

WARNING:

DO NOT BLOCK

THIS PIPE END!

 

Note: Untwist

INLET AIR

the pipe while

extending it, to

VENT PIPE

achieve full 30’

 

 

length.

Figure 7.4

Factory Built

Wood Burning

OPTIONAL LINK-ZC-ADPB

FOR USE WITH CLASS A

WOODBURNING PIPE

Remove 18 inch x 18 inch flashing on cap by removing 3 screws. Connect both the LINK-ZC-ADPB to Class A Pipe and the termination cap to the LINK-ZC-ADPB with the self tapping screws provided.

Heat & Glo • Supreme-XTS, Grand-XTS349-901 Rev. i • 12/09

13

 

Image 13
Contents What to do if you smell gas Models Supreme-XTS Grand-XTSHomeowner Reference Information CongratulationsTable of Contents Listing and Code Approvals Getting Started Design and Installation ConsiderationsTools and Supplies Needed Inspect Appliance and ComponentsMinimum Fireplace Opening Fireplace Size RequirementsClearances to Mantels or other Combustibles above Appliance ClearancesVent Termination Minimum Clearances Termination LocationsVent Table Key Vent Information and DiagramsHorizontal Venting Measuring StandardsInstallation Preparation Connecting Vent Pipe Installing Vent Pipe and ApplianceVenting Components Placing, Securing and Leveling the Appliance Factory Built Wood Burning Installing Adaptor and Termination CapDamper Flashing Kit Optional Fuel Conversions Gas Connection Gas InformationGas Pressures High Altitude Installations ON/OFF Switch Wiring the ApplianceElectrical Information Appliance RequirementsOptional Accessories Junction Box InstallationFAN Junction BOX Mantel Projections FinishingClean the Appliance Appliance SetupAccessories Ember PlacementPositioning the Logs Log Set Assembly LOGS-SXTHeat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. i 12/09 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. i 12/09 Log Set Assembly LOGS-GXT Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. i 12/09 Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. i 12/09 Air Shutter Setting Glass AssemblyBefore Lighting Appliance Operating InstructionsBefore operating this appliance have a qualified technician Standing Pilot Ignition Lighting ApplianceCheck Pilot Flame Appearance Initial Break-in ProcedureAfter Appliance is Lit Issue Solutions Frequently Asked QuestionsSymptom Possible Causes Corrective Action TroubleshootingStanding Pilot Ignition System Symptom Possible Cause Corrective Action TroubleshootingMaintaining and Servicing Appliance Maintenance TasksDoors, Surrounds Inspect Maintenance TasksReference Materials Appliance Dimension DiagramDirect Vent Flex Liner Kits Vent Kits ComponentsLimited Lifetime Warranty Heat & Glo Supreme-XTS, Grand-XTS 349-901 Rev. i 12/09 Contact Information