Bosch Appliances 28i junior, 24i junior manual Electrics

Page 28

1

2

A

B

C3

ROOMSTAT

ONLY

4

7

ELECTRICS

CAUTION: ISOLATE THE MAINS ELECTRICITY SUPPLY BEFORE STARTING ANY WORK AND OBSERVE ALL RELEVANT SAFETY PRECAUTIONS

Mains supply to the boiler must be through a fused double pole isolator situated adjacent to the appliance. The isolator must have a contact separation of 3mm minimum in all poles. External fuse rating 3A.

When stripping wires always ensure copper strands do not fall into the control box.

Access to electrical connections:

 

ROOMSTAT

 

 

 

 

 

 

 

 

 

 

 

 

ROOMSTAT

 

 

 

 

 

 

AND

 

INSTALLATION

 

 

 

 

 

PROGRAMMER

PROGRAMMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

230V

 

 

live

 

 

 

SUPPLYMAINS 6

 

earth

switched

live

neutral

blue

green/yellow

brown

ST10

F1

D

5

8

FROSTSTAT

ST6

F3

F2

Remove boiler casing to access control panel.

1Unscrew screw (A) and lower the control box into the horizontal position.

2Unscrew the three screws (B) in the control panel and pull off the connections cover.

3 Unclip cable clamp (C).

4Cut off the tapered cable entry to fit cable diameter required.

5Turn cable retaining screw (D) anti-clockwise. Run cable over the main crossbar and through the cable clamp (C), ensuring there is ample cable to reach the connectors.

Turn cable clamping screw (D) clockwise to secure cable.

After wiring to connectors is complete, snap cable clamp (C) into control box.

6Mains power 230v connection (ST10): Separate wires from cable end and

strip to 6mm

Connect LIVE wire to terminal (L)

Connect NEUTRAL wire to the terminal (N) Connect EARTH wire to the bracket

NOTE: Earth cable to be longer so that it pulls out last if mains cable is snagged.

7 230V room stat/clock (ST10):

The diagram shows the option of roomstat with programmer or roomstat only.

Remove link.

Connect LIVE supply to terminal (LS). Connect SWITCHED LIVE to terminal (LR),

NOTE: This is sometimes refered to as ‘call for heat’ or ‘heating load’.

Connect NEUTRAL to terminal (NS). NOTE: Some devices do not require this.

8Optional external frost stat connection (ST6): Connect froststat cables to terminals (FS) and (FR). These are not polarity sensitive.

9 Refit panels.

27

ELECTRICS

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior 8 716 107 336b (11/05)

Image 28
Contents Appliance is for USE with Natural GAS or L.P.G. Cat II 2H3P Type C13 & C33Natural GAS Liquid Petroleum GASContact Information Installation & Servicing Instructions Installation & Servicing InstructionsContents Safety Precautions Installation RegulationsSpecifications General InformationGeneral Information Standard PackageTechnical Data Technical DataLayout & Components Layout & ComponentsGAS Inlet Connection 22mm Compression Trap / SyphonLayout & Components Cleaning Primary Systems Cleaning Primary SystemsCleaning the Primary System Open all drain cocks and drainMains Supply Mains SupplyWater Systems & Pipework Water Systems & PipeworkCondensate Pipework Condensate PipeworkPressure Relief Pipework Pressure Relief PipeworkVentilation Free Compartments Installation Clearances Servicing Clearances Vented CompartmentBoiler Location Clearances Boiler Location & ClearancesBoiler Location BathroomsPlumbing Manifold Plumbing ManifoldConnections Heating System 22mm compression fittingsFlue Terminal Positions Flue Terminal PositionsDrwg Terminal Position Distance From a terminal facing the terminal 1200mmFlue Options Flue OptionsUnpacking Wall Frame Ancillary Items Ancillary ItemsImportant Handling Instructions Unpacking Wall FrameWall Mounting Template Flue Opening Wall Mounting Plate Flue OpeningUnpacking the Appliance Unpacking the ApplianceBoiler Connections Boiler ConnectionsGAS and Water Connections Flue Installation Flue Installation189mm 93mm Edge of case 200mm 250mm min Turret Clamp FlueAddition of Flue Bends Assembling the Flue Fitting the FlueFitting the Elbow Additional Notes and RemindersCondensate Connection Condensate ConnectionCondensate Connection Electrics ElectricsPosition of Wired Components Position of Wired ComponentsChecks PRE-COMMISSIONINGPRE-COMMISSIONING Checks Filling the System Filling the SystemStarting the Appliance Switching the appliance on/offStarting the Appliance Water Treatment KEYWater Treatment Commissioning CommissioningInstalling Bottom Panel Finishing CommissioningFinishing Commissioning Replace Outer CasingInspection and Service Inspection and ServiceInspection Component Access Adjusting boiler control to Service positionRemoving outer case Primary Heat ExchangerSetting Boiler to Maximum Boiler will stay in this mode forTo maximum AgainTo Clean the Heat Exchanger Inspection and Service Small Tab Replacement of Parts Replacement of PartsPrimary sensor Overheat thermostatMoving boiler control to service position Gas adjusterGas valve SiphonPCB fuse Access to boiler control componentsTransformer / PCB 12.1 12.212.3 Replacing control14.4 13.2 13.314.2 15.3 15.1 15.218.4 18.1 18.2 18.3 19.1 20.121.1 21.2 22.1 22.223.1 23.2 24.125.1 26.1 26.228.1 28.2 27.1Hydraulic Block 27.229.1 29.230.1 Plastic protection device31.1 31.232.1 32.2 32.333.3 33.4Short Parts List 1112 1415 1718 2021 2324G. Conversion Code plugsCode plug G. ConversionFault Finding Fault FindingCentral Heating Function Ignition SequenceCentral Heating Function Preheat and DHW Function Preheat and DHW FunctionProtection Function Protection FunctionGAS Boiler Commissioning Checklist Service Interval Record Excellence Comes AS Standard Bonded Washer 3/4
Related manuals
Manual 20 pages 44.58 Kb

28i junior, 24i junior specifications

Bosch Appliances has long been synonymous with quality and innovation in the kitchen. Among its notable offerings, the Bosch 24i Junior stands out as a compact yet powerful dishwasher that caters to modern household needs. This appliance is designed to provide efficient cleaning while conserving valuable space in smaller kitchens.

One of the key features of the Bosch 24i Junior is its compact size, measuring 24 inches in width. This makes it an optimal choice for apartments, smaller homes, or kitchens with limited space. Despite its size, it does not compromise on capacity, allowing users to load up to 12 place settings, making it suitable for families or frequent entertainers.

The Bosch 24i Junior incorporates advanced cleaning technologies that set it apart from traditional dishwashers. One of these technologies is the PrecisionWash system, which uses intelligent sensors to monitor the cleanliness of dishes throughout the wash cycle. This ensures that each item receives the optimal amount of water and detergent, resulting in sparkling clean dishes every time.

Energy efficiency is another hallmark of the Bosch 24i Junior. It operates on a low water consumption model, using only 2.9 gallons of water per cycle, which is significantly lower than many competitors. This not only helps lower utility bills but is also a step towards more sustainable living. The Energy Star certification further emphasizes its commitment to reducing energy usage without sacrificing performance.

Bosch has also integrated sound-dampening technology in the 24i Junior, ensuring that it operates quietly at just 50 dBA. This low noise level means that the dishwasher can run at any time of day or night without disturbing household activities.

User convenience is enhanced through features such as the ExtraScrub option, which provides a more powerful wash for heavily soiled items. The adjustable racks offer flexibility for loading larger pots and pans, while the foldable tines accommodate a range of dishware sizes.

In summary, the Bosch 24i Junior is a versatile and efficient dishwasher that is ideal for those with limited space. Its thoughtful design and innovative technologies make it a standout choice for anyone seeking reliable dish cleaning solutions without compromising on performance or efficiency. This model exemplifies Bosch's dedication to delivering cutting-edge appliances that fit seamlessly into modern lifestyles.