Bosch Appliances 24i junior, 28i junior manual Key, Water Treatment

Page 33

A

C

2

D

E

3

FG

4

H

I

J

KEY

Valve

Flushing

Agent

Inhibitor

1

5

 

 

 

WATER TREATMENT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

IMPORTANT: Debris from the system

 

 

J

 

 

 

 

can damage the boiler and reduce

B

 

 

 

 

 

 

efficiency. Failure to comply with the

 

 

 

 

 

 

 

guidelines for the use of water

 

 

 

 

 

 

 

treatment with the appliance will

 

 

 

K

 

 

 

invalidate the appliance warranty.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ENSURE THAT THE SYSTEM HAS BEEN

 

 

 

 

 

 

CLEANED AS ON PAGE 8 OF THESE

 

 

 

 

 

 

INSTRUCTIONS.

 

 

 

 

 

 

FLUSHING (Central Heating):

 

 

 

 

 

 

1 Switch off the boiler (A).

 

 

 

 

 

 

 

Open all drain cocks (B) and drain the

 

 

L

 

 

 

 

system (C) while the appliance is hot.

 

 

 

 

 

2 Close drain cocks (D) and add a suitable

 

 

 

 

 

 

 

 

 

 

 

 

 

flushing agent (E) at the correct strength for

 

 

 

 

 

 

 

the system condition in accordance with the

 

 

 

 

 

 

 

manufacturer's instructions.

 

 

 

 

 

 

3 Run the boiler/system at normal operating

 

 

 

 

 

 

 

temperature (F) for the time stated by the

 

 

 

 

 

 

 

manufacturer of the flushing agent (G).

 

 

 

 

 

 

4 Drain (H) and thoroughly flush the system to

 

 

 

 

 

 

 

remove the flushing agent and debris ( I ).

 

7

 

 

 

 

INHIBITOR (Central Heating):

 

M

 

 

 

5 Check drain cocks are closed ( J ) and all

 

 

 

 

 

 

radiator valves are open (K) before adding a

 

 

 

 

 

 

 

suitable*inhibitor (or combined inhibitor/anti-

 

 

 

 

 

 

 

freeze if the system is exposed to freezing

 

 

 

 

 

 

 

conditions) to the heating system water (L) in

 

 

 

 

 

 

 

accordance with the manufacturers instructions.

 

 

 

 

 

 

6 Fill system via a WRAS approved filling loop

 

 

 

 

 

 

 

to between 1 and 2 bar.

 

 

 

 

 

 

7 Vent all radiators; retighten vents when

 

 

 

 

 

 

 

complete (M). Vent any air from the boiler

 

 

 

 

 

 

 

heat exchanger using a suitable container to

 

 

 

 

N

 

 

collect any water (N).

 

 

 

 

 

 

Ensure tube outlet (O) is directed away

 

 

O

 

 

 

 

 

 

 

 

 

 

from the fan or any other electrical

 

 

 

 

 

 

 

component to prevent damage. Also

 

 

 

 

 

 

 

place a suitable cover over the fan to

 

 

 

 

 

 

 

prevent any spillage of water onto

 

 

 

 

 

 

 

electrical connections. Ensure the cover

 

 

 

 

 

 

 

is removed after venting.

 

 

 

 

 

 

8 Vent all radiators (P).

 

 

 

 

 

 

 

Re-pressurise if necessary to 1bar (Q).

 

8

P

 

 

 

 

 

 

 

 

 

Set all controls to maximum (R).

 

 

 

 

 

 

 

Record the date when the inhibitor was

 

 

 

 

 

 

 

added to the system on the guarantee card.

 

 

 

 

 

 

NOTE: The concentration level of inhibitor in

 

 

 

 

 

 

the system should be checked every 12

 

 

 

 

 

 

months, or sooner if system content is lost.

 

 

 

 

 

 

The addition of sealing agents to the system

 

 

 

 

 

 

water is not recommended as this can cause

 

Q

 

 

 

 

problems with deposits left in the heat exchang-

 

 

 

 

 

 

er.

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

* compatible with aluminium. The pH

 

 

 

 

 

 

 

 

value of the system water must be

 

 

 

 

 

 

 

 

less than 8 or the appliance guarantee

 

 

 

 

 

 

 

 

will be invalidated.

 

 

 

 

 

 

 

 

 

 

COMMISSIONING

32

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior 8 716 107 336b (11/05)

WATER TREATMENT

Image 33
Contents Natural GAS or L.P.G. Cat II 2H3P Type C13 & C33 Appliance is for USE withNatural GAS Liquid Petroleum GASInstallation & Servicing Instructions Contact Information Installation & Servicing InstructionsContents Installation Regulations Safety PrecautionsGeneral Information SpecificationsGeneral Information Standard PackageTechnical Data Technical DataLayout & Components Layout & ComponentsGAS Inlet Connection 22mm Compression Trap / SyphonLayout & Components Cleaning Primary Systems Cleaning Primary SystemsCleaning the Primary System Open all drain cocks and drainMains Supply Mains SupplyWater Systems & Pipework Water Systems & PipeworkCondensate Pipework Condensate PipeworkPressure Relief Pipework Pressure Relief PipeworkServicing Clearances Vented Compartment Ventilation Free Compartments Installation ClearancesBoiler Location Clearances Boiler Location & ClearancesBathrooms Boiler LocationPlumbing Manifold Plumbing ManifoldConnections Heating System 22mm compression fittingsFlue Terminal Positions Flue Terminal PositionsDrwg Terminal Position Distance From a terminal facing the terminal 1200mmFlue Options Flue OptionsAncillary Items Unpacking Wall Frame Ancillary ItemsImportant Handling Instructions Unpacking Wall FrameWall Mounting Plate Flue Opening Wall Mounting Template Flue OpeningUnpacking the Appliance Unpacking the ApplianceBoiler Connections Boiler ConnectionsGAS and Water Connections Flue Installation Flue Installation189mm 93mm Edge of case 200mm 250mm min Turret Clamp FlueAddition of Flue Bends Fitting the Flue Assembling the FlueFitting the Elbow Additional Notes and RemindersCondensate Connection Condensate ConnectionCondensate Connection Electrics ElectricsPosition of Wired Components Position of Wired ComponentsPRE-COMMISSIONING ChecksPRE-COMMISSIONING Checks Filling the System Filling the SystemSwitching the appliance on/off Starting the ApplianceStarting the Appliance KEY Water TreatmentWater Treatment Commissioning CommissioningFinishing Commissioning Installing Bottom PanelFinishing Commissioning Replace Outer CasingInspection and Service Inspection and ServiceInspection Adjusting boiler control to Service position Component AccessRemoving outer case Primary Heat ExchangerBoiler will stay in this mode for Setting Boiler to MaximumTo maximum AgainTo Clean the Heat Exchanger Inspection and Service Small Tab Replacement of Parts Replacement of PartsPrimary sensor Overheat thermostatGas adjuster Moving boiler control to service positionGas valve SiphonAccess to boiler control components PCB fuseTransformer / PCB 12.2 12.112.3 Replacing control13.2 13.3 14.414.2 15.1 15.2 15.318.4 18.1 18.2 18.3 20.1 19.121.1 21.2 22.1 22.224.1 23.1 23.225.1 26.1 26.227.1 28.1 28.2Hydraulic Block 27.229.2 29.130.1 Plastic protection device31.2 31.132.1 32.2 32.333.4 33.31112 1415 1718 2021 2324 Short Parts ListCode plugs G. ConversionCode plug G. ConversionFault Finding Fault FindingIgnition Sequence Central Heating FunctionCentral Heating Function Preheat and DHW Function Preheat and DHW FunctionProtection Function Protection FunctionGAS Boiler Commissioning Checklist Service Interval Record Bonded Washer 3/4 Excellence Comes AS Standard
Related manuals
Manual 20 pages 44.58 Kb

28i junior, 24i junior specifications

Bosch Appliances has long been synonymous with quality and innovation in the kitchen. Among its notable offerings, the Bosch 24i Junior stands out as a compact yet powerful dishwasher that caters to modern household needs. This appliance is designed to provide efficient cleaning while conserving valuable space in smaller kitchens.

One of the key features of the Bosch 24i Junior is its compact size, measuring 24 inches in width. This makes it an optimal choice for apartments, smaller homes, or kitchens with limited space. Despite its size, it does not compromise on capacity, allowing users to load up to 12 place settings, making it suitable for families or frequent entertainers.

The Bosch 24i Junior incorporates advanced cleaning technologies that set it apart from traditional dishwashers. One of these technologies is the PrecisionWash system, which uses intelligent sensors to monitor the cleanliness of dishes throughout the wash cycle. This ensures that each item receives the optimal amount of water and detergent, resulting in sparkling clean dishes every time.

Energy efficiency is another hallmark of the Bosch 24i Junior. It operates on a low water consumption model, using only 2.9 gallons of water per cycle, which is significantly lower than many competitors. This not only helps lower utility bills but is also a step towards more sustainable living. The Energy Star certification further emphasizes its commitment to reducing energy usage without sacrificing performance.

Bosch has also integrated sound-dampening technology in the 24i Junior, ensuring that it operates quietly at just 50 dBA. This low noise level means that the dishwasher can run at any time of day or night without disturbing household activities.

User convenience is enhanced through features such as the ExtraScrub option, which provides a more powerful wash for heavily soiled items. The adjustable racks offer flexibility for loading larger pots and pans, while the foldable tines accommodate a range of dishware sizes.

In summary, the Bosch 24i Junior is a versatile and efficient dishwasher that is ideal for those with limited space. Its thoughtful design and innovative technologies make it a standout choice for anyone seeking reliable dish cleaning solutions without compromising on performance or efficiency. This model exemplifies Bosch's dedication to delivering cutting-edge appliances that fit seamlessly into modern lifestyles.