L. P. G. CONVERSION

 

 

I S O LATE MAI N S E LE CTR I C AL

 

 

SUPPLY AND REMOVE OUTER CASE

 

 

AS SHOWN IN THE INSTALLATION,

 

 

C O M M I S S I O N I N G & S E RVI C I N G

A

 

INSTRUCTIONS

 

 

THE CONVERSION MUST BE CARRIED OUT

 

 

BY A COM PETE NT PE R SON . IT M UST NOT

 

 

B E AT T E M P T E D U N L E S S T H E P E R S O N

 

 

C A R R Y I N G O U T T H E C O N V E R S I O N I S

2.1

2.2

EQUIPPED WITH A COMBUSTION ANALYSER

C O N F O R M I N G TO B S 79 2 7 A N D I S

 

 

COMPETENT IN IT’S USE.

Important: The appliance shall not be installed into a room or internal space below ground level when it is intended for use with LPG (propane - G31). This does not preclude the installation into a room or space which is a basement on one side of the building but open to ground on the opposite side.

 

Installation Regulations

 

In addition to those specified in the main

2.3

booklet the following standard applies when

 

converting to an LPG appliance: BS 5842

Domestic Propane Gas Burning

Installations.

B

3

All conversions will require the air gas ratio to be set correctly for the gas used . The procedure for setting the air gas ratio is at the rear of these instructions.

1.Moving boiler control to service position

Remove boiler case, as described on page 36.

1.1Remove screw (A) from retaining bracket.

1.2Lower control panel into service position.

2. Gas valve

 

 

Isolate gas supply at boiler gas cock.

 

2.1

Remove wire clip from gas valve outlet then

 

 

pull gas adjustment assembly free from

 

 

plastic connector and pull forward clear of

 

C

case.

 

2.2

Undo bottom gas connection to gas valve.

 

2.3

Undo two securing screws (B) on the

 

 

underside of casing.

 

 

Pull valve up and forward out of boiler.

 

 

Disconnect electrical connections.

4.1

4.2

Fit plastic retaining nut to the outlet of the

gas valve from the kit and hand tighten.

 

 

Replace valve with new seals.

Check for gas soundness.

A

E

D

Code plugs

24kW NG

-

100

24kW LPG

-

101

28kW NG

-

102

28kW LPG

-

103

3. Gas adjuster

Twist retaining clip (C) to release then remove clip and tube.

Refit new adjuster and secure with clip. Coloured red for LPG or black for NG.

4. Code plug

4.1Remove 3 screws (D) retaining plastic cover at rear of control box and remove.

4.2Replace code plug (E) with new one supplied with conversion kit. Replace plastic cover.

Place control in normal position and secure with screw.

TH E GAS / AI R R ATI O M U ST B E RESET AFTER CONVERSION . THE P R O C E D U R E CAN B E F O U N D I N THE REPLACEMENT PARTS SECTION OF THIS MANUAL.

CONVERSION KITS

54

INSTALLATION & SERVICING INSTRUCTIONS FOR WORCESTER GREENSTAR 24 i junior/28 i junior 8 716 107 336b (11/05)

L.P.G. CONVERSION

Image 55
Contents Liquid Petroleum GAS Appliance is for USE withNatural GAS or L.P.G. Cat II 2H3P Type C13 & C33 Natural GASInstallation & Servicing Instructions Contact Information Installation & Servicing InstructionsContents Installation Regulations Safety PrecautionsStandard Package SpecificationsGeneral Information General InformationTechnical Data Technical DataCompression Trap / Syphon Layout & ComponentsLayout & Components GAS Inlet Connection 22mmLayout & Components Open all drain cocks and drain Cleaning Primary SystemsCleaning Primary Systems Cleaning the Primary SystemMains Supply Mains SupplyWater Systems & Pipework Water Systems & PipeworkCondensate Pipework Condensate PipeworkPressure Relief Pipework Pressure Relief PipeworkBoiler Location & Clearances Ventilation Free Compartments Installation ClearancesServicing Clearances Vented Compartment Boiler Location ClearancesBathrooms Boiler LocationHeating System 22mm compression fittings Plumbing ManifoldPlumbing Manifold ConnectionsFrom a terminal facing the terminal 1200mm Flue Terminal PositionsFlue Terminal Positions Drwg Terminal Position DistanceFlue Options Flue OptionsUnpacking Wall Frame Unpacking Wall Frame Ancillary ItemsAncillary Items Important Handling InstructionsWall Mounting Plate Flue Opening Wall Mounting Template Flue OpeningUnpacking the Appliance Unpacking the ApplianceBoiler Connections Boiler ConnectionsGAS and Water Connections 250mm min Turret Clamp Flue Flue InstallationFlue Installation 189mm 93mm Edge of case 200mmAddition of Flue Bends Additional Notes and Reminders Assembling the FlueFitting the Flue Fitting the ElbowCondensate Connection Condensate ConnectionCondensate Connection Electrics ElectricsPosition of Wired Components Position of Wired ComponentsChecks PRE-COMMISSIONINGPRE-COMMISSIONING Checks Filling the System Filling the SystemStarting the Appliance Switching the appliance on/offStarting the Appliance Water Treatment KEYWater Treatment Commissioning CommissioningReplace Outer Casing Installing Bottom PanelFinishing Commissioning Finishing CommissioningInspection and Service Inspection and ServiceInspection Primary Heat Exchanger Component AccessAdjusting boiler control to Service position Removing outer caseAgain Setting Boiler to MaximumBoiler will stay in this mode for To maximumTo Clean the Heat Exchanger Inspection and Service Small Tab Overheat thermostat Replacement of PartsReplacement of Parts Primary sensorSiphon Moving boiler control to service positionGas adjuster Gas valvePCB fuse Access to boiler control componentsTransformer / PCB Replacing control 12.112.2 12.314.4 13.2 13.314.2 15.3 15.1 15.218.4 18.1 18.2 18.3 22.1 22.2 19.120.1 21.1 21.226.1 26.2 23.1 23.224.1 25.127.2 28.1 28.227.1 Hydraulic BlockPlastic protection device 29.129.2 30.132.3 31.131.2 32.1 32.233.4 33.31112 1415 1718 2021 2324 Short Parts ListG. Conversion G. ConversionCode plugs Code plugFault Finding Fault FindingCentral Heating Function Ignition SequenceCentral Heating Function Preheat and DHW Function Preheat and DHW FunctionProtection Function Protection FunctionGAS Boiler Commissioning Checklist Service Interval Record Bonded Washer 3/4 Excellence Comes AS Standard
Related manuals
Manual 20 pages 44.58 Kb

28i junior, 24i junior specifications

Bosch Appliances has long been synonymous with quality and innovation in the kitchen. Among its notable offerings, the Bosch 24i Junior stands out as a compact yet powerful dishwasher that caters to modern household needs. This appliance is designed to provide efficient cleaning while conserving valuable space in smaller kitchens.

One of the key features of the Bosch 24i Junior is its compact size, measuring 24 inches in width. This makes it an optimal choice for apartments, smaller homes, or kitchens with limited space. Despite its size, it does not compromise on capacity, allowing users to load up to 12 place settings, making it suitable for families or frequent entertainers.

The Bosch 24i Junior incorporates advanced cleaning technologies that set it apart from traditional dishwashers. One of these technologies is the PrecisionWash system, which uses intelligent sensors to monitor the cleanliness of dishes throughout the wash cycle. This ensures that each item receives the optimal amount of water and detergent, resulting in sparkling clean dishes every time.

Energy efficiency is another hallmark of the Bosch 24i Junior. It operates on a low water consumption model, using only 2.9 gallons of water per cycle, which is significantly lower than many competitors. This not only helps lower utility bills but is also a step towards more sustainable living. The Energy Star certification further emphasizes its commitment to reducing energy usage without sacrificing performance.

Bosch has also integrated sound-dampening technology in the 24i Junior, ensuring that it operates quietly at just 50 dBA. This low noise level means that the dishwasher can run at any time of day or night without disturbing household activities.

User convenience is enhanced through features such as the ExtraScrub option, which provides a more powerful wash for heavily soiled items. The adjustable racks offer flexibility for loading larger pots and pans, while the foldable tines accommodate a range of dishware sizes.

In summary, the Bosch 24i Junior is a versatile and efficient dishwasher that is ideal for those with limited space. Its thoughtful design and innovative technologies make it a standout choice for anyone seeking reliable dish cleaning solutions without compromising on performance or efficiency. This model exemplifies Bosch's dedication to delivering cutting-edge appliances that fit seamlessly into modern lifestyles.