TABLE 1.6a: CROWN CONCENTRIC 80/125 VENT COMPONENTS

(VENT OPTIONS 3,8)

 

 

 

USED ON

 

CROWN PN

DESCRIPTION

SIZE

VENT

COMMENTS

 

 

 

OPTION #

 

230527

90 DEGREE EL (STANDARD)

80/125mm

3,8

 

 

 

 

 

 

230528

90 DEGREE EL (SWEEP)

80/125mm

3,8

 

 

 

 

 

 

230526

45 DEGREE EL

80/125mm

3,8

 

 

 

 

 

 

230517

19 1/2” STRAIGHT

80/125mm

3,8

CAN BE CUT

 

 

 

 

 

230515

39” STRAIGHT

80/125mm

3,8

CAN BE CUT

 

 

 

 

 

230518

39” STRAIGHT

80/125mm

3,8

MAY NOT BE CUT

 

 

 

 

 

230519

78” STRAIGHT

80/125mm

3,8

MAY NOT BE CUT

 

 

 

 

 

230525

TELESCOPING STRAIGHT

80/125mm

3,8

ADJUSTABLE FROM 12-1/2” TO 16-1/2

 

 

 

 

 

230531

HORIZONTAL TERMINAL

80/125mm

3

 

 

 

 

 

 

230532

VERTICAL TERMINAL

80/125mm

8

(NOTE #1)

 

 

 

 

 

230533

FLAT ROOF FLASHING

80/125mm

8

 

 

 

 

 

 

230535

SLOPED ROOF FLASHING

80/125mm

8

(NOTE #2)

 

 

 

 

 

230530

SUPPORT ELBOW WITH

80/125mm

8

(NOTE #3)

CHIMNEY CHASE BRACKET

 

 

 

 

 

 

 

 

 

230536

SUPPORT BAND

80/125mm

3,8

 

 

 

 

 

 

Table 1.6a Notes:

1)Vertical terminal can be used with either of the roof flashings listed beneath it.

2)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.

3)Used at base of vertical run inside unused masonry chimney.

TABLE 1.6b: CROWN CONCENTRIC100/150 VENT COMPONENTS

(VENT OPTIONS 8,9)

 

 

 

USED ON

 

CROWN PN

DESCRIPTION

SIZE

VENT

COMMENTS

 

 

 

OPTION #

 

 

 

 

 

 

230567

90 DEGREE EL (SWEEP)

100/150mm

4,9

 

 

 

 

 

 

230565

45 DEGREE EL

100/150mm

4,9

 

 

 

 

 

 

230560

19 1/2” STRAIGHT

100/150mm

4,9

CAN BE CUT

 

 

 

 

 

230562

39” STRAIGHT

100/150mm

4,9

CAN BE CUT

 

 

 

 

 

230561

39” STRAIGHT

100/150mm

4,9

MAY NOT BE CUT

 

 

 

 

 

230563

78” STRAIGHT

100/150mm

4,9

MAY NOT BE CUT

 

 

 

 

 

230564

TELESCOPING STRAIGHT

100/150mm

4,9

ADJUSTABLE FROM 12-1/2” TO 17-1/2

 

 

 

 

 

230569

HORIZONTAL TERMINAL

100/150mm

4

 

 

 

 

 

 

230570

VERTICAL TERMINAL

100/150mm

9

(NOTE #1)

 

 

 

 

 

230571

FLAT ROOF FLASHING

100/150mm

9

 

 

 

 

 

 

230572

SLOPED ROOF FLASHING

100/150mm

9

(NOTE #2)

 

 

 

 

 

230568

SUPPORT ELBOW WITH

100/150mm

9

(NOTE #3)

CHIMNEY CHASE BRACKET

 

 

 

 

 

 

 

 

 

230573

SUPPORT BAND

100/150mm

4,9

 

 

 

 

 

 

Table 1.6b Notes:

1)Vertical terminal can be used with either of the roof flashings listed beneath it.

2)Sloped roof flashing suitable for roof angles between 25 and 45 degrees.

3)Used at base of vertical run inside unused masonry chimney.

8

Image 10
Contents BWC Series Page Page Concentric Venting For BWC150 and BWC225 Page Summary of Horizontal Venting Options Horizontal Concentric Venting Vent Option 3,4 3c Positioning Vent Terminal Under Overhangs VENT/ AIR Intake Fitting Equivalent Length Vent Options 3,8 Concentric Vent Adapter Kit Installation Concentric Vent Adapter Assembly Assembly of Crown Concentric Venting 10 Cutting Straight Pipe 11a Joining Cuttable Pipe 12a Dimension L, Horizontal Terminal 12c Cutting Inner Pipe of Horizontal Terminal 13a Dimension H 13b Cutting Vertical Terminal Machine Screw 15 Condensate Drain Line Assembly PN 980241 Rev BWC 12/07

M600 specifications

The Crown Boiler M600 is a prominent choice for residential and commercial heating needs, renowned for its efficiency, reliability, and advanced technologies. This boiler model is designed to deliver high-performance heating solutions while minimizing energy consumption and operational costs.

One of the standout features of the M600 is its impressive heating capacity, with the capability to output up to 600,000 BTUs. This substantial capacity makes it suitable for larger buildings or homes with significant heating demands, ensuring that spaces remain comfortably warm even in the coldest weather. The M600 is equipped with a robust cast iron heat exchanger, which is fundamental to its efficient heat transfer capabilities. This heat exchanger not only enhances performance but also extends the life of the boiler.

The Crown Boiler M600 employs a versatile design that accommodates both hot water and steam heating systems. This flexibility allows homeowners and building managers to choose the best system that aligns with their specific requirements. Additionally, the M600 features a power vent design, which facilitates the use of PVC venting materials, offering convenience and an array of installation options.

Another significant characteristic of the M600 is its user-friendly controls. The boiler is designed with a digital display that provides real-time status updates and diagnostics. This feature simplifies monitoring and managing system performance, enabling users to make necessary adjustments with ease. Moreover, the M600 is compatible with modern smart thermostats, further enhancing its energy efficiency and user-friendliness.

In terms of safety, the Crown Boiler M600 is equipped with multiple safety features, including a low water cut-off and high limit control. These safeguards ensure the boiler operates safely and effectively, reducing the risk of malfunctions and potential hazards.

Moreover, the M600 adheres to stringent efficiency standards, boasting an AFUE (Annual Fuel Utilization Efficiency) rating that meets or exceeds industry requirements. This ensures that users benefit from optimal fuel efficiency, translating into lower operational costs.

Overall, the Crown Boiler M600 stands out as a durable and efficient heating solution. With its high-output capacity, advanced technologies, user-friendly features, and safety measures, it is an excellent choice for those seeking reliable heating in larger residential or commercial spaces.