Bryant BW1, BW4B, BS1 Model Number Nomenclature, Boiler Accessories, BW9AAN000075AAAA, Description

Page 2

MODEL NUMBER NOMENCLATURE

BW9AAN000075AAAA

 

 

 

B

 

 

W

 

9

 

A

 

 

A

 

N

 

000

 

 

075

 

A

 

 

A

 

 

AA

 

B — Boiler

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Variations

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AA — Standard

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Type of System

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Series

 

 

 

 

 

W — Water

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

S — Steam

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A — Original

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustion/Ignition

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Labeling

 

 

 

1

— Natural Draft/Standing Pilot

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2

— Natural Draft/Electronic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

A — Common Unit

 

 

 

3

— Induced Draft/Electronic

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

G — Canada Only (oil)

 

 

 

4

— Oil Burner/Without Tankless Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5

— Oil Burner/With Tankless Coil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

— 90% Direct Vent/Sealed

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Combustion

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Model Code

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Electrical

 

 

 

 

 

 

 

 

 

 

 

Heating Size

 

 

 

 

 

 

 

 

 

 

 

 

 

A 110 to 125 60 Hz

 

 

 

 

 

 

 

 

 

 

 

Btu Input (x 1000)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Fuel

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

H — Heating Oil

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N — Natural Gas

 

 

 

 

 

 

 

Cooling

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

P — Propane

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BOILER ACCESSORIES

 

 

 

BW1/BW2

 

DESCRIPTION

PART NO.

 

 

Filtrol Package (Up to 75,000 Btuh Input)

KBAFP0101DNK

 

 

Filtrol Package (Up to 150,000 Btuh Input)

KBAFP0201DNK

 

 

Filtrol Package (Over 150,000 Btuh Input)

KBAFP0301DNK

 

 

High Limit Control

KBAHL0101DNK

 

 

Combustible Floor Base (2 thru 6 section models)

KBASB0301DNK

 

 

Combustible Floor Base (7 thru 9 section models)

KBASB0401DNK

 

 

Zoning Valve 3/4 in.

KBAZV0101DNK

 

 

Zoning Valve 1 in.

KBAZV0201DNK

 

 

Gas Conversion Kit Natural to Propane (After 1799V)

KBANP0201DNK

 

 

Gas Conversion Kit Propane to Natural

KBAPN0201DNK

 

 

NOTE: There was never a Natural to Propane conversion kit for BW/BS boiler prior to 1799V.

 

 

 

BW3

 

DESCRIPTION

PART NO.

 

 

Filtrol Package (Up to 75,000 Btuh Input)

KBAFP0101DNK

 

 

Filtrol Package (Up to 150,000 Btuh Input)

KBAFP0201DNK

 

 

Filtrol Package (Over 150,000 Btuh Input)

KBAFP0301DNK

 

 

High Limit Control

KBAHL0101DNK

 

 

Combustible Floor Base (2 thru 6 section models)

KBASB0301DNK

 

 

Combustible Floor Base (6 thru 7 section models)

KBASB0401DNK

 

 

Zoning Valve 3/4 in.

KBAZV0101DNK

 

 

Zoning Valve 1 in.

KBAZV0201DNK

 

 

Gas Conversion Kit Natural to Propane (After 1799V)

KBANP0201DNK

 

 

Gas Conversion Kit Propane to Natural

KBAPN0201DNK

 

 

NOTE: There was never a Natural to Propane conversion kit for BW/BS boiler prior to 1799V.

 

 

 

BS1/BS2

 

DESCRIPTION

PART NO.

 

 

Combustible Floor Base (2 thru 6 section models)

KBASB0301DNK

 

 

See notes on page 3.

—2—

Image 2
Contents Model BW4B, BW5B Model BW9 Model BW1, BW2 Model BW3Model BS1, BS2 BW9AAN000075AAAA Boiler AccessoriesModel Number Nomenclature DescriptionBW4/BW5 Water Boiler Circulator Curve Circulator CurveStandard Boiler Warranties Yrs ALL ModelsSpecifications Models BW9Ratings and Capacities DimensionsClearances Unit Type Btuh Capacity Btuh Afue %Models BS1 and BS2 General DataModels BS1 and BS2 Unit Size Vent DiameterModels BW1 and BW2 Sections Unit Size Vent ConnectionShip Model BW3 GAS Controls Intermittent PilotBW3 Models Unit Type BtuhModels BW4 and BW5 Ratings and Performance