Bryant BS1, BW4B, BS2, BW5B, BW3, BW9 manual Models BW1 and BW2

Page 9

MODELS BW1 and BW2

Models BW1 and BW2 Gas-Fired Hot Water Boilers provide fast heat quietly and economically to assure the finest in hydronic heating.

These boilers provide quality design in a small, compact unit easily installed in a basement, garage, or utility room. They can be installed on a combustible floor when an optional combustible floor base is used.

The models BW1 and BW2 design is CSA and A.G.A. certified for use with natural and is convertible to propane gas with accessory kit.

FEATURES

RANGE OF CAPACITIES—Sizes 37,500 through 280,000 Btuh are available.

COMPLETELY PACKAGED—Each boiler is completely assembled, including all controls (except room thermostat). All necessary wiring is factory installed. The boiler is ready for gas, water, room thermostat, and electrical connections as shipped.

THERMAL-PIN, CAST-IRON SECTIONS—These sections speed heat transfer from the flue gases to the boiler water with faster thermostat response, providing greater comfort and economy. Maximum heat is produced at a lower level on the thermal-pin sections, leading to peak efficiency.

INTEGRAL DRAFT—These boilers incorporate an integral draft sys- tem to simplify installation. No external draft diverter is needed. TITANIUM COMPOSITE BURNERS—Provide quiet operation, corrosion resistance and improved combustion efficiency. Propane convertible – with accessory kit.

CONTROLS—An automatic gas valve and continuous pilot or inter- mittent pilot provide quiet, dependable operation of the burners. Factory-installed safety components assure protection against overheating, pressure buildup, and low-water operation.

INSULATED CASING—The casing is fully insulated with fiberglass for maximum operating efficiency and economy.

AUTOMATIC VENT DAMPERThe Model BS1 and BS2 is designed with automatic vent damper to recover chimney loss during off cycle.

SECTIONS TESTEDEach section is hydrostatically tested to 50 psig. Individual sections are tested to 125 psig at factory. Assembled sections are tested to 75 psig at the factory. The maximum allowable pressure is 50 psig for hot water boilers.

WARRANTY—The cast-iron sections are covered by a non-prorated 20-year warranty on the entire assembly. Vent damper covered by 5- year warranty. Circulator pump covered by 3-year warranty. All other parts are covered by a 1-year limited warranty.

SPECIFICATIONS

UNIT SIZE

 

 

 

037

 

070

 

105

 

 

140

 

 

175

 

 

210

 

 

245

 

 

280

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GENERAL DATA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sections—Fine Grain Cast Iron

 

No.

 

2

 

3

 

4

 

 

5

 

 

6

 

 

7

 

 

8

 

 

9

Burners—Stainless/Titanium Alloy

 

No.

 

1

 

2

 

3

 

 

4

 

 

5

 

 

6

 

 

7

 

 

8

Burners—Orifice Drill Size

Natural

 

34

 

34

 

34

 

 

34

 

 

34

 

 

34

 

 

34

 

 

34

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS CONTROLS — STANDING PILOT (BW1)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve

 

 

 

 

 

 

 

 

 

 

Honeywell

 

 

 

 

 

 

 

Inlet Size

 

In.

 

 

 

 

 

 

1/2 FPT

 

 

 

 

 

 

 

 

 

3/4 FPT

Pilot Assembly

 

 

 

 

 

 

 

 

 

 

Honeywell

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GAS CONTROLS — INTERMITTENT PILOT (BW2)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Gas Valve

 

 

 

 

 

 

 

 

 

 

Honeywell

 

 

 

 

 

 

 

Inlet Size

 

In.

 

 

 

 

 

 

1/2 FPT

 

 

 

 

 

 

 

 

 

3/4 FPT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pilot Assembly

 

 

 

 

 

 

 

 

 

 

Honeywell

 

 

 

 

 

 

 

Spark Generator

 

 

 

 

 

 

 

 

 

 

Honeywell/UTEC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CONTROLS

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Limit Control Range

 

°F

 

 

 

 

 

 

 

 

 

140–240

 

 

 

 

 

 

 

Pressure/Temperature Gage

 

Psig

 

 

 

 

 

 

 

 

 

10–70

 

 

 

 

 

 

 

 

 

°F

 

 

 

 

 

 

 

 

 

60–320

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Pressure Relief Valve Setting

 

Psig

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

Circulator Relay—Aquastat

 

 

 

 

 

 

 

 

Honeywell (Factory Installed)

 

 

 

 

 

 

 

Vent Damper*

 

In.

 

4†

 

5

 

 

6

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

CIRCULATOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Taco

Model

 

 

 

 

 

 

 

 

 

007

 

 

 

 

 

 

 

 

 

Full Load Amps

 

 

 

 

 

 

 

 

 

 

 

0.70

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Flange Size FPT

 

In.

 

 

 

 

 

 

 

 

 

1-1/4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Factory authorized and listed, field installed.

A 4-in. vent damper is supplied. A 4-in. to 3-in. reducer is also furnished.

—9—

Image 9
Contents Model BW1, BW2 Model BW3 Model BS1, BS2Model BW4B, BW5B Model BW9 Model Number Nomenclature Boiler AccessoriesBW9AAN000075AAAA DescriptionBW4/BW5 Standard Boiler Warranties Yrs Circulator CurveWater Boiler Circulator Curve ALL ModelsModels BW9 SpecificationsClearances DimensionsRatings and Capacities Unit Type Btuh Capacity Btuh Afue %General Data Models BS1 and BS2Unit Size Vent Diameter Models BS1 and BS2Models BW1 and BW2 Unit Size Vent Connection ShipSections GAS Controls Intermittent Pilot Model BW3Unit Type Btuh BW3 ModelsModels BW4 and BW5 Ratings and Performance