Table summarising error codes

 

 

Green Leds

 

 

 

 

 

 

Reset

 

Note

 

Temperature indicator

 

 

 

 

Description

= flashing light

 

 

 

 

 

 

40

50

60

70

80

90

yellow

red

 

 

● = lit

 

 

 

 

 

 

 

 

X

Overheat

 

 

 

 

 

 

 

 

X

Insufficient circulation

 

 

 

 

 

 

 

Insufficient water (request filling)

 

 

 

 

 

 

C.H. Flow temp. probe circuit open / short circuit

 

 

 

 

 

 

C.H. Return temp. probe circuit open / short circuit

 

 

 

 

 

 

External sensor circuit open / short circuit

 

 

 

 

 

 

Floor thermostat contact open

 

 

 

 

 

 

 

X

Heating delivery probe problem

 

 

 

 

 

 

Insufficient circulation

 

 

 

 

 

 

 

 

EEPROM error

 

 

 

 

 

 

 

 

Communication error

 

 

 

 

Too many (> 5) resets in 15 minutes

 

 

 

 

 

 

 

 

X

Main P.C.B. error

 

 

 

 

 

 

 

Room sensor circuit open / short circuit

 

 

 

 

 

 

 

 

 

X

No flame detected

 

 

 

 

 

 

Flame detected with gas valve closed

 

 

 

 

 

 

X

Flame lift

 

 

 

 

 

 

1st Ignition Failed

 

 

 

 

 

 

2nd Ignition Failed

 

 

 

 

 

 

Flame cut-off

 

 

 

 

 

 

 

 

X

Thermofuse open

 

 

 

 

 

 

 

 

X

Fan speed error

 

Anti-frost Device.

When the electrical supply is turned on, the anti-frost function acts on the central heating flow temperature probe, independently from other safety devices.

If the primary circuit temperature is between 3°C and 8°C the pump will run (with the diverter valve switching between central heating and hot water every 1 minute) until the temperature reaches > 9°C.

If the flow temperature remains between 3°C and 8°C the pump will continue to run for a maximum of 20 minutes unless a temperature above > 9°C is detected in the central heating flow, after this the burner will fire (heating position) until a temperature of > 30°C is detected.

If the central heating flow temperature is < 3°C, the burner will fire (heating position) at minimum power until the temperature reaches > 30°C, the burner will go out.

If lockout is caused by overheat the burner will not fire but the pump will continue to run (heating position).

The anti-frost device activates only when (with the boiler operating correctly):

-the system pressure is correct;

-the boiler is electrically powered;

-there is a supply of gas.

Change of gas type

Our boilers are designed to function either with Natural Gas (meth- ane) or L.P.G. gas. If you need to change from one gas to the other, one of our Authorised Service Centres must be contacted to convert the appliance.

Maintenance

Schedule an annual maintenance check-up for the boiler with a com- petent person.

Correct maintenance generally results in savings in the cost of run- ning the system.

Failure to arrange an annual service for the appliance will invalidate the second year of the manufacturer’s guarantee.

7

Image 7
Contents Combi 24/30/38 System24/30 92/42/CEE CE labelling90/396/CEE 2004/108/CEEBenchmark Scheme Safety regulationsSystem Control panelDomestic Hot Water temperature adjustment E-COMBI Initial operating procedures Filling instructionsIgnition procedure Adjusting the heatingOperation shutdown Safety shut-offClock Instructions E-COMBI Boiler protection devices Shutdown due to insufficient water circulationChange of gas type Table summarising error codesMaintenance Anti-frost Device420010275700

47 - 116 - 63, 41 - 116 - 34, 41 - 116 - 35, 47 - 116 - 62, 47 - 116 - 64 specifications

Ariston is a well-known brand in the realm of heating solutions, with products designed to meet diverse needs for comfort and efficiency. Among its notable offerings are the models Ariston 47 - 116 - 64, 47 - 116 - 62, 41 - 116 - 35, 41 - 116 - 34, and 47 - 116 - 63. Each of these models is engineered with specific features that cater to varying demands in heating systems, making Ariston a trusted choice for consumers looking for reliability and performance.

The Ariston 47 - 116 - 64 is characterized by its high-efficiency heat exchange technology, which ensures optimal energy use, translating to lower utility bills. Combining this with advanced control systems allows users to fine-tune temperature settings for maximum comfort. It features a sleek design, making it suitable for modern homes, and its compact nature allows for easy installation in limited spaces.

Similarly, the 47 - 116 - 62 model emphasizes user-friendly controls with intuitive interfaces to simplify operation. This unit is also engineered with robust materials that enhance durability, ensuring years of reliable service. Its energy-saving rating is particularly appealing for environmentally-conscious consumers, as it contributes to reduced carbon footprints.

The Ariston 41 - 116 - 35 model supports advanced connectivity options, enabling users to control their heating systems remotely via smartphone applications. This feature not only adds convenience but also allows for better energy management. The model is built to cope with varying load demands, making it adaptable for residential or commercial settings.

In addition, the 41 - 116 - 34 is praised for its silent operation, catering to those who prioritize tranquility in their living environments. It incorporates cutting-edge noise reduction technology, making it ideal for bedrooms or study areas.

Finally, the Ariston 47 - 116 - 63 rounds out this series with its powerful heating capability. Designed to heat larger spaces efficiently, it maintains consistent temperatures across various rooms, providing comprehensive coverage.

Overall, each Ariston model boasts distinctive features, state-of-the-art technologies, and excellent performance characteristics, ensuring comfort and efficiency in diverse applications. Whether for a home, office, or commercial space, the Ariston series meets the demands of modern heating needs while prioritizing sustainability and user control.