Crown Boiler AWI195, TWI095, TWI128, TWI061, TWI162, AWI061, AWI162, AWI229, AWI262 Specifications

Page 5

TABLE1:SPECIFICATIONS

BASIC

 

RATINGS - NATURAL AND LP GASES

*

 

 

DIMENSIONS (INCHES)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOE

I=B=R NET

 

 

 

 

 

 

 

BOILER

NUMBER

 

INPUT

 

HEATING

RATING,

AFUE

 

 

 

 

 

 

MODEL

 

 

 

CAPACITY

WATER

 

 

 

 

 

 

 

OF

 

 

 

 

"A"

"B"

"C"

"D"

"E"

"F"

 

 

 

 

 

 

 

 

 

SECTIONS

 

MBH

 

MBH

MBH

%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI037S

2

 

37

 

30

26

 

80.0

10-1/2

 

7-1/4

4

3-5/8

3-7/8

AWI037E

 

 

 

82.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI061S

3

 

61

 

50

43

 

80.0

11-3/4

 

5-7/8

4

3-5/8

1-7/8

AWI061E

 

 

 

82.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI095S

4

 

95

 

78

68

 

80.1

15

27-7/8

7-1/2

5

4-1/8

1-7/8

AWI095E

 

 

 

82.3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI128S

5

 

128

 

105

91

 

80.2

18-1/4

 

9-1/8

6

4-5/8

1-7/8

AWI128E

 

 

 

82.0

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI162S

6

 

162

 

132

115

 

80.3

21-1/2

 

10-3/4

6

4-5/8

1-7/8

AWI162E

 

 

 

81.7

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI195S

7

 

195

 

159

138

 

80.4

24-3/4

 

12-3/8

7

5-1/8

1-7/8

AWI195E

 

 

 

81.4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI229S

8

 

229

 

186

162

 

80.4

28

 

14

7

5-1/8

1-7/8

AWI229E

 

 

 

81.2

 

 

 

 

 

 

 

 

 

29-7/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI262S

9

 

262

 

212

184

 

80.5

31-1/4

15-5/8

8

5-5/8

1-7/8

 

 

 

 

AWI262E

 

 

 

80.9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

AWI295S

10

 

295

 

238

207

 

80.7

34-1/2

 

17-1/4

8

5-5/8

1-7/8

AWI295E

 

 

 

80.6

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

RATINGS - NATURAL GAS ONLY

 

 

DIMENSIONS (INCHES)

 

BASIC

NUMBER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DOE

I=B=R NET

 

 

 

 

 

 

 

BOILER

OF

 

INPUT

 

HEATING

RATING,

AFUE

 

 

 

 

 

 

MODEL

SECTIONS

 

 

 

CAPACITY

WATER

 

"A"

"B"

"C"

"D"

"E"

"F"

 

 

 

 

 

 

 

 

 

 

 

 

MBH

 

MBH

MBH

%

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWI061E

3

 

61

 

51

44

 

83.0

11-3/4

 

5-7/8

4

3-5/8

1-7/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWI095E

4

 

95

 

79

69

 

83.0

15

 

7-1/2

5

4-1/8

1-7/8

 

 

 

 

 

 

 

 

 

 

27-7/8

 

 

 

 

TWI128E

5

 

128

 

106

92

 

83.0

18-1/4

9-1/8

6

4-5/8

1-7/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TWI162E

6

 

162

 

134

117

 

83.0

21-1/2

 

10-3/4

6

4-5/8

1-7/8

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Notes:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Suffix E = Intermittent Ignition, Suffix S = Standing Pilot

Add Suffix N for Natural Gas or Suffix L for Propane Gas to basic AWI Boiler Model shown (Example: AWI295EN, AWI229SL)

5

3

Image 5
Contents Crown Inside Front Cover Leave Blank Product Description Table of ContentsII Specifications Bleftpipedconfiguration Specifications IV Locating the Boiler III Before InstallingFor Buildings of Other than Unusually Tight Construction Air for Combustion and VentilationExample ALL AIR from Outdoors Ventilated Crawl Space and Attic For Buildings of Unusually Tight ConstructionVI Venting ALL AIR from OUTDOORS, Using Openings Into Boiler RoomTypicalventsystem Installation and Components 1210 Removing an Existing Boiler from a Common ChimneyGAS Connection to Boiler VII Gas PipingStandardPiping Viii System PipingStandard Boiler Piping Piping for Special SituationsIndirect Water Heater Boiler Bypass Piping Single Zone Wiring IX WiringWiring DIAGRAM, Continuous Ignition Circulator Zonewiring Using HONEYWELLR845As Wiring VariationsSequence of Operation, Standing Pilot AWI/TWI Control System Sequence of OperationSequence of Operation, Intermittent Ignition Start-up and Checkout Page Standing Pilot Burner Flame For Your Safety Read Before Operating For Your Safety Read Before Lighting GAS Valve Detail Standing Pilot XI Service and Maintenance Heat Exchanger Cleaning Procedure XII Troubleshooting AWI/TWI Troubleshooting Chart END Standing Pilot Ignition System Troubleshooting Chart Intermittent Ignition System Troubleshooting Chart Xiii Parts Base-Block-Hood Below 2000 ft Burner Components KEY # Description QTY. or Quantity PER Boiler or Crown P.N Jacket/Components Crown

AWI262, AWI095, TWI095, AWI195, AWI037 specifications

Crown Boiler is a renowned name in the heating industry, providing high-quality, efficient heating solutions that cater to various residential and commercial needs. Among its impressive lineup, the AWI and TWI series stand out for their design, technology, and performance.

The Crown Boiler AWI061 and TWI061 are part of the Hydronic Boiler range, designed to deliver efficient hot water heating. The AWI series features an advanced pressure-jet design that allows it to operate with exceptional fuel efficiency, reducing operating costs for homeowners and businesses alike. Additionally, these models come equipped with an integrated pump system that ensures a consistent supply of hot water, making them ideal for both space heating and domestic hot water applications.

Meanwhile, the AWI162 and AWI128 models are engineered for higher output, addressing larger heating needs without compromising efficiency. These models showcase a robust heat exchanger made of durable cast iron, promoting longevity and effective heat transfer. The AWI series boilers feature a modern control system that allows for precise temperature management, enhancing comfort while minimizing energy consumption.

The Crown Boiler AWI295, on the other hand, steps up with a significant heating capacity suited for commercial applications. This model is designed with advanced safety and efficiency technologies, including an intelligent control module that monitors temperature and pressure, ensuring optimal performance while preventing malfunctions. The large water volume design allows for enhanced thermal stability and consistent heating output.

A notable characteristic across these models is their ease of installation and maintenance. Crown Boiler has engineered the units with user-friendly features, including accessible components and simplified diagnostics that help technicians service the boilers swiftly. Moreover, the durability of cast iron construction ensures that these units can withstand high thermal stress while delivering reliable performance over the years.

In summary, Crown Boiler’s AWI061, TWI061, AWI162, AWI128, and AWI295 models offer a range of solutions equipped with advanced technologies and features designed for efficiency and reliability. These boilers are suitable for diverse heating needs, promising optimal comfort and convenience in both residential and commercial settings. With Crown Boiler's longstanding commitment to quality, customers can be assured of a robust heating solution backed by exceptional service.