NOTE: The tee may be rotated into any position so that the collar is in a convenient orientation.

4)APPLIANCE ADAPTER INSTALLATION

a)Apply a bead of red silicone sealant (supplied) to the boiler vent collar approx. 1” from end of collar. (Figure 7a)

b)Remove all oil and grease from the inside of the appliance adapter, and apply a bead of red silicone sealant to inside of adapter ½” from end (Figure 7a).

c)With a twisting motion, assemble the appliance adapter onto the vent collar.

d)Using a block of wood on the end of the adapter, push the adapter onto the vent collar, using care to avoid damaging the vent collar or the adapter (Figure 7b).

e)Keep the sampling port in the 12 o’clock position and align the prepunched slots in the appliance adapter to the threaded holes on the vent collar.

f)Secure the appliance adapter to the boiler vent collar with (3) 1/4-20 x 1/2” stainless steel cap screws inserted into the three tapped holes in the appliance collar and tighten. (Figure 6b).

g)Apply red silicone sealant to the end of the adapter and anchoring screws. (Figure 7b).

h)After testing and burner adjustments have been made, apply red silicone sealant to the supplied 3/8” sampling port plug screw and install the screw in the sampling port (Figure 7b).

i)Maintain clearances to combustibles. If the appliance adapter is within 18” of combustible material, wrap minimum 1-1/2” ceramic insulation (installer-supplied) around the exposed portion of the appliance adapter.

5)OPTIONAL REDUCING TEE ADAPTER INSTALLATION

a)An optional reducing tee adapter is available for use in place of the standard appliance adapter (Figure 8a). This reduces the clearance needed from the back of the boiler.

b)Apply a bead of red silicone sealant (supplied) to appliance collar approx. 1” from end of the boiler vent collar. (Figure 8a)

c)Remove all oil and grease from the inside of the reducing tee adapter, and apply a bead of red silicone sealant to inside of adapter ½” from end (Figure 8b).

9

Image 12
Contents Freeport ODV Series Page Table of Contents Product Description II Specifications SpecificationsIII Before Installing IV Locating the BoilerVent System Installation Page Installing the FDVS-4 Vent Terminal Page Page Appliance Adapter Installation Page Vent Pipe Installation AIR Intake Pipe Installation VI System Piping Standard PipingPage Piping for Special Situations Page VII Fuel Piping Viii Wiring IX Start-up and Checkout Service Notes ODV Burner Applications XI Maintenance Avoid Breathing Fiber Particulates and Dust Section XII Replacement Parts Boiler Parts ODV-75, ODV = Not Pictured Page PN 98-100 10/10 Rev.4

ODV-75, ODV-100, ODV-125 specifications

Crown Boiler Company is renowned for producing high-quality heating solutions, and their ODV series is no exception. The ODV-125, ODV-100, and ODV-75 models are part of this advanced product line, designed for residential and light commercial applications. These models exemplify Crown Boiler's commitment to innovation, performance, and efficiency.

One of the main features of the ODV series is its unique vertical design, which helps in optimizing space in various settings, making them ideal for installations where space is at a premium. Each model is engineered to provide reliable heating with output capacities of 125, 100, and 75 MBH respectively. This range allows homeowners to select a unit that best meets their specific heating demands, ensuring comfort without unnecessary energy expenditure.

Technology plays a crucial role in the performance of the ODV series. The units are equipped with stainless steel burners that provide enhanced durability and efficiency. These burners are designed to achieve high combustion efficiency, minimizing fuel consumption and reducing emissions. Additionally, the ODV models feature an integrated electronic ignition system which ensures a reliable start-up and reduces the wear and tear associated with traditional standing pilot systems.

When it comes to construction, the ODV series units are built with a heavy-duty steel casing that provides excellent thermal insulation. This design not only contributes to the efficiency of the boilers but also ensures quiet operation, making them suitable for residential environments. The corrosion-resistant heat exchanger further enhances longevity, providing homeowners with peace of mind regarding their investment.

Another characteristic that sets the ODV series apart is its versatility. These boilers can be configured for use with multiple heating applications, including hot water supply and radiant heating systems. The ODV models also feature easy access to internal components for maintenance and servicing, which is a significant advantage for HVAC professionals.

In summary, the Crown Boiler ODV-125, ODV-100, and ODV-75 models represent the pinnacle of residential heating technology. With their efficient design, advanced burner technology, and ease of maintenance, these units are sure to provide reliable performance for years to come. Whether for a cozy home or a light commercial space, the ODV series offers a solution that balances comfort, efficiency, and durability.