Crown Boiler ODV-75, ODV-100, ODV-125 manual VII Fuel Piping

Page 20

VII Fuel Piping

IMPORTANT

Installation of oil storage tanks, fill pipes, and oil lines must conform to local code requirements. In the absence of any codes, installation must be in conformance with ANSI/NFPA-31.

Use of this boiler with an unenclosed above ground outdoor oil tank is not recommended.

Two basic piping systems are used to connect the boiler to the oil supply:

1)One-Pipe – Recommended where the fuel pump is below the lowest possible level of the oil in the tank. Basic piping is shown in Figure 21a.

2)Two-Pipe – Recommended where the fuel pump is above the lowest possible level of the oil in the tank. This system is self-priming. Basic piping is shown in Figure 21b.

Consult the instructions supplied with the pump for limitations on lift, horizontal run, and required line sizes. Pumps supplied with the ODV boiler generally require the installation of a bypass plug when converted for use in a two-pipe system. See the pump instructions for specific information. Also note the following:

1)If the boiler is being installed as a replacement, the existing oil system may be two-pipe even though the pump is below the lowest level in the oil tank. Such systems should be converted to one-pipe systems as doing so will result in warmer oil temperatures, lower vacuums, and longer filter life.

17

Image 20
Contents Freeport ODV Series Page Table of Contents Product Description II Specifications SpecificationsIII Before Installing IV Locating the BoilerVent System Installation Page Installing the FDVS-4 Vent Terminal Page Page Appliance Adapter Installation Page Vent Pipe Installation AIR Intake Pipe Installation VI System Piping Standard PipingPage Piping for Special Situations Page VII Fuel Piping Viii Wiring IX Start-up and Checkout Service Notes ODV Burner Applications XI Maintenance Avoid Breathing Fiber Particulates and Dust Section XII Replacement Parts Boiler Parts ODV-75, ODV = Not Pictured Page PN 98-100 10/10 Rev.4

ODV-75, ODV-100, ODV-125 specifications

Crown Boiler Company is renowned for producing high-quality heating solutions, and their ODV series is no exception. The ODV-125, ODV-100, and ODV-75 models are part of this advanced product line, designed for residential and light commercial applications. These models exemplify Crown Boiler's commitment to innovation, performance, and efficiency.

One of the main features of the ODV series is its unique vertical design, which helps in optimizing space in various settings, making them ideal for installations where space is at a premium. Each model is engineered to provide reliable heating with output capacities of 125, 100, and 75 MBH respectively. This range allows homeowners to select a unit that best meets their specific heating demands, ensuring comfort without unnecessary energy expenditure.

Technology plays a crucial role in the performance of the ODV series. The units are equipped with stainless steel burners that provide enhanced durability and efficiency. These burners are designed to achieve high combustion efficiency, minimizing fuel consumption and reducing emissions. Additionally, the ODV models feature an integrated electronic ignition system which ensures a reliable start-up and reduces the wear and tear associated with traditional standing pilot systems.

When it comes to construction, the ODV series units are built with a heavy-duty steel casing that provides excellent thermal insulation. This design not only contributes to the efficiency of the boilers but also ensures quiet operation, making them suitable for residential environments. The corrosion-resistant heat exchanger further enhances longevity, providing homeowners with peace of mind regarding their investment.

Another characteristic that sets the ODV series apart is its versatility. These boilers can be configured for use with multiple heating applications, including hot water supply and radiant heating systems. The ODV models also feature easy access to internal components for maintenance and servicing, which is a significant advantage for HVAC professionals.

In summary, the Crown Boiler ODV-125, ODV-100, and ODV-75 models represent the pinnacle of residential heating technology. With their efficient design, advanced burner technology, and ease of maintenance, these units are sure to provide reliable performance for years to come. Whether for a cozy home or a light commercial space, the ODV series offers a solution that balances comfort, efficiency, and durability.