Crown Boiler ODV-125, ODV-100, ODV-75 manual Product Description

Page 4

WARNING

FAILURE TO VENT THIS BOILER IN ACCORDANCE WITH THESE INSTRUCTIONS COULD CAUSE FLUE GAS TO ENTER THE BUILDING RESULTING IN SEVERE PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH:

Do not attempt to vent this boiler with galvanized, PVC, or any other vent components not described in this manual

Do not obtain combustion air from within the building.

Do not install a barometric damper or vacuum relief valve in the vent system of this boiler.

CAUTION

Moisture and ice may form on the surfaces around the vent termination. To prevent deterioration, surfaces should be in good repair (sealed, painted, etc.).

DANGER

THE VENT SYSTEM SUPPLIED WITH THE ODV IS NOT DESIGNED FOR VENTING OF FLUE PRODUCTS FROM NATURAL GAS OR PROPANE. DO NOT ATTEMPT TO CONVERT THE ODV TO EITHER GAS.

I Product Description

The ODV series boiler is a cast iron oil fired boiler designed for use in forced hot water heating systems. The ODV boiler must be vented using the factory supplied venting system with combus- tion air taken from outdoors. The ODV uses the same three pass “scotch marine” heat exchanger as the CT series boiler. The ODV series boiler is ideal for use in installations where a chimney is not available.

The ODV boiler is not designed for use in gravity or “open” heating systems.

CAUTION

As with any oil appliance, certain adverse conditions can cause this boiler to operate at high smoke levels. Since the ODV is vented through a wall, this can result in severe soot damage to the side of the structure around the terminal. To minimize the risk of this:

Follow these installation instructions exactly

Oil burner must be set up by a qualified serviceman using combustion test instruments

Use only the vent components supplied in the ODV vent kit

Combustion air must be supplied from outdoors

Follow the maintenance procedure in this manual

Use only #2 fuel oil meeting ASTM D-396

1

Image 4
Contents Freeport ODV Series Page Table of Contents Product Description II Specifications SpecificationsIII Before Installing IV Locating the BoilerVent System Installation Page Installing the FDVS-4 Vent Terminal Page Page Appliance Adapter Installation Page Vent Pipe Installation AIR Intake Pipe Installation VI System Piping Standard PipingPage Piping for Special Situations Page VII Fuel Piping Viii Wiring IX Start-up and Checkout Service Notes ODV Burner Applications XI Maintenance Avoid Breathing Fiber Particulates and Dust Section XII Replacement Parts Boiler Parts ODV-75, ODV = Not Pictured Page PN 98-100 10/10 Rev.4

ODV-75, ODV-100, ODV-125 specifications

Crown Boiler Company is renowned for producing high-quality heating solutions, and their ODV series is no exception. The ODV-125, ODV-100, and ODV-75 models are part of this advanced product line, designed for residential and light commercial applications. These models exemplify Crown Boiler's commitment to innovation, performance, and efficiency.

One of the main features of the ODV series is its unique vertical design, which helps in optimizing space in various settings, making them ideal for installations where space is at a premium. Each model is engineered to provide reliable heating with output capacities of 125, 100, and 75 MBH respectively. This range allows homeowners to select a unit that best meets their specific heating demands, ensuring comfort without unnecessary energy expenditure.

Technology plays a crucial role in the performance of the ODV series. The units are equipped with stainless steel burners that provide enhanced durability and efficiency. These burners are designed to achieve high combustion efficiency, minimizing fuel consumption and reducing emissions. Additionally, the ODV models feature an integrated electronic ignition system which ensures a reliable start-up and reduces the wear and tear associated with traditional standing pilot systems.

When it comes to construction, the ODV series units are built with a heavy-duty steel casing that provides excellent thermal insulation. This design not only contributes to the efficiency of the boilers but also ensures quiet operation, making them suitable for residential environments. The corrosion-resistant heat exchanger further enhances longevity, providing homeowners with peace of mind regarding their investment.

Another characteristic that sets the ODV series apart is its versatility. These boilers can be configured for use with multiple heating applications, including hot water supply and radiant heating systems. The ODV models also feature easy access to internal components for maintenance and servicing, which is a significant advantage for HVAC professionals.

In summary, the Crown Boiler ODV-125, ODV-100, and ODV-75 models represent the pinnacle of residential heating technology. With their efficient design, advanced burner technology, and ease of maintenance, these units are sure to provide reliable performance for years to come. Whether for a cozy home or a light commercial space, the ODV series offers a solution that balances comfort, efficiency, and durability.