Crown Boiler ODV-100, ODV-125, ODV-75 manual = Not Pictured

Page 30

VENTING ASSEMBLY

KEY #

ITEM #

Consisting of:

DESCRIPTION

QTY

 

ODV SERIES

 

 

 

 

 

 

 

 

 

 

 

ODV-75

 

ODV-100

ODV-125

1

12-000A

 

FDVS-47 Terminal Kit

1

*

 

*

 

*

2

12-030A

X

FDVS-47 Terminal

1

*

 

*

 

*

3

12-033A

X

Combustion Air Tee (w/ Cover Pan N/P)

1

*

 

*

 

*

4

12-020A

X

4" Nominal Dia. Flexible Air Intake Pipe

20 ft

*

 

*

 

*

5

12-036A

X

Cover Ring

2

*

 

*

 

*

6

12-037A

X

Inner Pipe Clamp

4

*

 

*

 

*

7

12-005A

X

Cover Sleeves

2

*

 

*

 

*

8

12-001A

X

Appliance Adapter

1

*

 

*

 

*

N/P

12-032A

X

Backing Plate

1

*

 

*

 

*

N/P

12-035

X

4" Nominal Dia. Hose Clamp

2

*

 

*

 

*

N/P

900850A

X

3/8-16 x 1/2" SS Slotted Hex Screw

1

*

 

*

 

*

N/P

Procure Locally

X

1/4-20 x1" Hex Bolt

4

*

 

*

 

*

N/P

X

1/4-20 Square Machine Nut

4

*

 

*

 

*

 

 

 

N/P

 

X

1/4-20 x 1/2" SS Cap Screw

3

*

 

*

 

*

N/P

12-010

X

1/4" x 2" Lag Screw

4

*

 

*

 

*

N/P

X

1/4" Flat Washer

7

*

 

*

 

*

 

 

 

N/P

 

X

Cable Clamp

2

*

 

*

 

*

N/P

12-050

X

Tube Hi-Temp Silicone

2

*

 

*

 

*

9

12-015A

Individually Boxed

FOVP-415 Flexible Insulated Oil Vent Pipe

15 ft

*

 

*

 

*

10

120100

Individually Boxed

RT-74 Reducing Tee

1

optional

 

optional

 

optional

BUNRNER ASSEMBLY

KEY #

ITEM #

 

DESCRIPTION

QTY

 

ODV SERIES

 

 

 

Consisting of:

 

 

ODV-75

ODV-100

ODV-125

N/P

13-151

 

CARLIN BURNER ASSY. ODV-75

1

*

 

 

N/P

13-152

 

CARLIN BURNER ASSY. ODV-100

1

 

*

 

N/P

13-153

 

CARLIN BURNER ASSY. ODV-125

1

 

 

*

N/P

 

13-150

CARLIN EZ-1 MODIFIED BURNER

1

*

*

*

N/P

 

13-167

DELAVAN 0.65/70W NOZZLE

1

*

 

 

N/P

 

13-114

DELAVAN 0.85.60A NOZZLE

1

 

*

 

N/P

 

13-136

DELAVAN 1.00/60A NOZZLE

1

 

 

*

N/P

 

12-120

AIR INLET COLLAR

1

*

*

*

N/P

 

90-222

10-32 x 1/8 I.D. HOSE BARB

1

*

*

*

N/P

 

90-219

10-32 S.S. HEX NUT (FOR HOSE BARB)

1

*

*

*

N/P

 

12-085

ODV PRESSURE SWITCH BRACKET

1

*

*

*

N/P

 

12-070

ODV PRESSURE SWITCH

1

*

 

 

N/P

 

12-075

ODV PRESSURE SWITCH

1

 

*

 

N/P

 

12-080

ODV PRESSURE SWITCH

1

 

 

*

N/P

 

96-1020

PRESSURE SWITCH HARNESS

1

*

*

*

N/P

 

14-008

.125 I.D. SILICONE TUBING (INLET SIDE)

1.2 ft

*

*

*

N/P

 

14-008

.125 I.D. SILICONE TUBING (EXHAUST SIDE)

5.84 ft

*

*

*

N/P = Not Pictured

27

Image 30
Contents Freeport ODV Series Page Table of Contents Product Description II Specifications SpecificationsIII Before Installing IV Locating the BoilerVent System Installation Page Installing the FDVS-4 Vent Terminal Page Page Appliance Adapter Installation Page Vent Pipe Installation AIR Intake Pipe Installation VI System Piping Standard PipingPage Piping for Special Situations Page VII Fuel Piping Viii Wiring IX Start-up and Checkout Service Notes ODV Burner Applications XI Maintenance Avoid Breathing Fiber Particulates and Dust Section XII Replacement Parts Boiler Parts ODV-75, ODV = Not Pictured Page PN 98-100 10/10 Rev.4

ODV-75, ODV-100, ODV-125 specifications

Crown Boiler Company is renowned for producing high-quality heating solutions, and their ODV series is no exception. The ODV-125, ODV-100, and ODV-75 models are part of this advanced product line, designed for residential and light commercial applications. These models exemplify Crown Boiler's commitment to innovation, performance, and efficiency.

One of the main features of the ODV series is its unique vertical design, which helps in optimizing space in various settings, making them ideal for installations where space is at a premium. Each model is engineered to provide reliable heating with output capacities of 125, 100, and 75 MBH respectively. This range allows homeowners to select a unit that best meets their specific heating demands, ensuring comfort without unnecessary energy expenditure.

Technology plays a crucial role in the performance of the ODV series. The units are equipped with stainless steel burners that provide enhanced durability and efficiency. These burners are designed to achieve high combustion efficiency, minimizing fuel consumption and reducing emissions. Additionally, the ODV models feature an integrated electronic ignition system which ensures a reliable start-up and reduces the wear and tear associated with traditional standing pilot systems.

When it comes to construction, the ODV series units are built with a heavy-duty steel casing that provides excellent thermal insulation. This design not only contributes to the efficiency of the boilers but also ensures quiet operation, making them suitable for residential environments. The corrosion-resistant heat exchanger further enhances longevity, providing homeowners with peace of mind regarding their investment.

Another characteristic that sets the ODV series apart is its versatility. These boilers can be configured for use with multiple heating applications, including hot water supply and radiant heating systems. The ODV models also feature easy access to internal components for maintenance and servicing, which is a significant advantage for HVAC professionals.

In summary, the Crown Boiler ODV-125, ODV-100, and ODV-75 models represent the pinnacle of residential heating technology. With their efficient design, advanced burner technology, and ease of maintenance, these units are sure to provide reliable performance for years to come. Whether for a cozy home or a light commercial space, the ODV series offers a solution that balances comfort, efficiency, and durability.