White Rodgers 1F80-71 Check Thermostat Operation, Fan Operation, Heating System, Cooling System

Page 4

CHECK THERMOSTAT OPERATION

NOTE

If at any time during testing, your system does not operate properly, contact a qualified serviceperson.

Fan Operation

1.Turn on power to the system.

2.Press SYSTEM button until the system is OFF.

3.Move FAN switch to ON. The blower should begin to operate.

4.Move FAN switch to AUTO position. The blower should stop within a short period of time.

Heating System

1.Press SYSTEM button until HEAT is displayed. If the heating system has a standing pilot, be sure to light it.

2.Press to adjust thermostat setting above room tempera- ture. The heating system should begin to operate.

3.Press to adjust temperature setting below room tem- perature. The heating system should stop operating.

Cooling System

This thermostat has a built-in short-term (5-minute) time delay. This feature is activated after the compressor shuts down and the setpoint is changed within the 5-minute period. During this 5-minute period, COOL will flash on the display indicating that the thermostat has locked out the compressor to allow head pressure to stabilize. This thermostat does not sense AC power loss and therefore does not activate the short term compressor protection feature when power is restored.

!CAUTION

To prevent compressor and/or property damage, if the outdoor temperature is below 50°F, DO NOT operate the cooling system.

1.Press SYSTEM button until COOL is displayed.

2.Press to adjust thermostat setting below room tempera- ture. The blower should come on immediately on high speed, followed by cold air circulation

3.Press to adjust temperature setting above room tem- perature. The cooling system should stop operating.

LOCKOUT BYPASS OPTION

FOR QUALIFIED SERVICE TECHNICIANS’ USE ONLY. OPERATORS SHOULD NOT USE THIS FEA- TURE DUE TO POSSIBILITY OF EQUIPMENT OR PROPERTY DAMAGE, OR PERSONAL INJURY.

COMPRESSOR SHORT TERM

CYCLE PROTECTION

This thermostat has a built-in short term (5-minute) time delay. During this 5-minute period, the thermo- stat will lock out the compressor to allow head pres- sure to stabilize. If you want to override this feature

while testing thermostat operation, simply press and buttons at the same time.

DO NOT USE THE LOCKOUT BYPASS OPTION UNLESS THE COMPRESSOR OIL HEATERS HAVE BEEN OPERATIONAL FOR 6 HOURS AND THE SYSTEM HAS NOT BEEN OPERATIONAL FOR AT LEAST 5 MINUTES.

4

Image 4
Contents Precautions SpecificationsDescription Part no -6120AInstallation PRE-INSTALLATION SET-UPInstalling the Thermostat Remove OLD ThermostatCUT Tape OFF Check Thermostat Operation Fan OperationHeating System Cooling SystemOperation Thermostat BaseSet Current Time and Day Entering Your ProgramEnter Heating Program Check Your Programming TroubleshootingEnter Cooling Program

1F80-71 specifications

The White Rodgers 1F80-71 is a versatile and advanced programmable thermostat that has gained recognition for its user-friendly interface and reliable performance. Designed for optimal energy efficiency, this device allows homeowners to have better control over their heating and cooling systems, ultimately leading to significant cost savings and increased comfort.

One of the standout features of the 1F80-71 is its 7-day programmable schedule, which enables users to customize heating and cooling settings for different days of the week. This means you can set specific times for your heating or air conditioning to activate, tailored to your daily and weekly routines. The flexibility of programming allows users to save energy during times when they are not at home, while ensuring that the home is at a comfortable temperature when they return.

The thermostat incorporates a large, easy-to-read display that provides clear visibility of current settings, temperatures, and programming options. The intuitive interface simplifies the setup process, making it accessible even for those who may not be tech-savvy. Additionally, the touchscreen controls enhance the user experience, allowing for seamless navigation through various functions.

Connectivity is another important feature of the 1F80-71. Equipped with Wi-Fi capability, the thermostat allows homeowners to monitor and adjust their home's climate remotely through a smartphone app. This convenience ensures that users can make temperature adjustments on-the-go, creating a significant advantage for those with busy lifestyles.

Energy-saving technologies are integrated into the thermostat, including features like Smart Recovery, which learns how long it takes to heat or cool a space. This allows the system to begin heating or cooling before the programmed time, ensuring that the desired temperature is reached by the scheduled time while minimizing energy use.

In addition, the White Rodgers 1F80-71 supports both heating and cooling systems, including heat pumps, central heating, and air conditioning units. This wide compatibility ensures that it can be seamlessly integrated into various home setups, making it an excellent choice for any household.

Overall, the White Rodgers 1F80-71 programmable thermostat stands out for its combination of advanced features, energy efficiency, and user-friendly design. Whether for new installations or upgrades, this thermostat represents a smart investment in home comfort and energy management.