MAKING THE GAS CONNECTION:

NOTE: IF THE OPTIONAL FORCED BLOWER KIT (PART # 129161) IS TO BE INSTALLED ON THE STOVE AT THE TIME OF THE INSTALLATION OR IN THE FUTURE, THE GAS SUPPLY LINE SHOULD BE INSTALLED AS CLOSE TO THE FLOOR AS POSSIBLE.

USE OF A 90° ELBOW DIRECTLY OFF THE VALVE WILL ALLOW FOR PROPER CLEARANCE FOR THE BLOWER.

The gas supply line connection is made to the valve just inside the left rear leg. The Gas supply line should be a minimum of 3/8" in diameter, or the appropriate size to provide sufficient gas pressure to the valve regardless of the input setting.

The use of Flexible Gas Appliance Connectors is acceptable in many areas in the U.S.; However, Canadian methods vary depending on local code.

ALL INSTALLATIONS MUST COMPLY WITH LOCAL CODE OR IN THE ABSENCE OF LOCAL CODE, MUST COMPLY WITH THE MOST RECENT EDITION OF THE NATIONAL FUEL GAS CODE ANSI Z223.1/ NFPA 54 OR CAN-B149.

All codes require: a gas shut-off valve (gas cock) and union, to be installed in the supply line, and in the same room as the appliance. This allows for the disconnection of the stove for servicing and maintenance. See Figure 5.

Figure 5

T-handle gas cocks are required in Massachusetts in compliance with code 248CMR.

Secure all joints tightly using appropriate tools and sealing compounds (for propane units, be sure to use compounds that are propane resistant). Turn on gas supply and test for gas leaks using a soapy water solution. Never use an open flame to check for leaks.

Leak test:

·Mix a 50-50 solution of water and dish soap.

·Light appliance- see lighting instructions on page 23 of this manual or on the stove’s rating plate.

·Brush or spray all joints and connections with the soapy water solution.

·If bubbles appear at any connection or seam or a gas odor is detected, immediately turn gas control knob to the OFF position.

Tighten or reconnect the leaking joint and retest for any gas leaks.

GAS PRESSURE:

Correct gas pressure is essential for efficient and safe operation of the Allagash gas stove. It is important that the correct pressure is established at the time of the installation.

Proper gas pressure provides a consistent flow of gas to the appliance and is instrumental in checking for gas leaks.The gas control valve on the stove is equipped with pressure test points for gauge connections. The gauge connections are located on the front of the valve under the On/Off/Pilot- knob. Gauge connections are identified by:

Efor inlet or supply pressure (the amount of gas coming to the valve.)

Afor manifold pressure (the amount of gas that is coming out of the valve to the burner.)

E A

Pressure test point as located on the front of the valve.

12

Image 12
Contents GF 3 BV Allagash Warnock HerseyTable of Contents Model Allagash B-Vent Gas StoveWelcome to Jøtul Input RatesStandards Do not Operate this Stove if ANY Part has Been Under WaterHot Surfaces Blower/Electrical HazardLocation Floor Protection Stove ClearancesRear clearance =250mm Corner clearance =376mmVenting Requirements Firestop is required at every floor Venting Configurations for GAS Conversion Tools requiredIncluded in the conversion kit Remove the regulator tower and the gasket Making the GAS Connection GAS PressureHigh Altitude Installations Necessary Inlet GAS PressuresInches water column Necessary Manifold PressuresAIR Shutter ADJUSTMENT/FLAME Appearance GAS Type Orifice Elevation Jøtul SizeInstalling the LOG SET Installing the Optional Blower ReminderInstalling the Optional Wall Thermostat or Remote Spill SwitchChecking the System Maintenance Operation of ApplianceService LOG Allagash B-VENT Parts List GF3 BV Allagash Illustrated Parts Breakdown Lighting Instructions Jøtul ASA

GF 3 BV specifications

The Jotul GF 3 BV is a gas-burning fireplace that combines classic design with modern technology, making it a popular choice for homeowners seeking both style and efficiency. This model is part of the renowned Jotul family, known for their high-quality craftsmanship and lasting durability.

One of the standout features of the Jotul GF 3 BV is its impressive heat output. With an efficiency rating that rivals many wood-burning stoves, this gas fireplace can easily warm up larger spaces, making it ideal for living rooms, family areas, or open floor plans. The unit delivers a maximum input of 20,000 BTUs, allowing it to provide substantial warmth without the hassle of traditional wood fires.

The design of the Jotul GF 3 BV reflects a timeless aesthetic that can suit various interior styles. It features a beautiful cast iron construction, which not only contributes to its durability but also adds a classic touch to the ambiance of any room. The unit is available in multiple finishes, including natural gas and propane, allowing homeowners to choose the best option that fits their existing decor and preferences.

In terms of technology, the Jotul GF 3 BV includes an innovative venting system that allows for flexible installation options. This system is designed to minimize the need for extensive chimney work, making the unit easier to install in various settings. Additionally, the fireplace is equipped with a ceramic glass window that provides an unobstructed view of the flames while maintaining the efficiency of the fire.

Another significant characteristic of the Jotul GF 3 BV is its intuitive control system. This allows users to easily adjust the flame height and heat output, providing customizable comfort levels at the touch of a button. The fireplace can also be integrated with remote control options for added convenience, showing Jotul's commitment to modernizing traditional fireplace experiences.

Overall, the Jotul GF 3 BV is an excellent choice for those looking for an efficient, stylish, and easy-to-use gas fireplace. With its combination of classic design, high efficiency, and user-friendly features, it represents a perfect blend of form and function for contemporary living spaces. Whether you are renovating your home or simply seeking an efficient heating solution, the Jotul GF 3 BV delivers on all fronts.