Desa Tech SL30PT Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 13

OWNER’S MANUAL

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

LIGHTING

INSTRUCTIONS

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open a window to vent smell. This will only last a few hours.

1.STOP! Read the safety information, column 1.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise Clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, column 1. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

C-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 22).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 14.

Ignitor Button

Control Knob

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 22- Control Knob and Ignitor Button Location

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 3 through 7.This heater has a safety inter- lock system. Wait one (1) minute for sys- tem to reset before lighting pilot again.

8.Turn control knob counterclockwise

C-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

Pilot Burner

Thermocouple

Figure 23 - Pilot

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

Turn control knob clockwise Clockwise to the OFF position.

Shutting Off Burners Only (pilot stays lit)

Turn control knob clockwise Clockwise to the PILOT position.

Continued

104464

13

Image 13
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualVENT-FREE PROPANE/LP GAS Stove Heater Safety InformationSafety Pilot Product Identification Product FeaturesLocal Codes OperationProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsCheck GAS Type InstallationClearances to Combustibles Vent-Free Operation OnlyRemoving Back Panel Stove Cavity AssemblyAttaching Stove Legs Washers to reattach back panel later Installing GAS LOG Heater Into StoveInstallation Items Needed Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Operating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To ApplianceService Hints SpecificationsTechnical Service Inspecting BurnersCleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceLogs Main BurnerObserved Problem Possible Cause TroubleshootingMaintenance, Observed Problem Possible Cause RemedyTop Cleaning KIT CCK AccessoriesParts Centrals Equipment Shutoff Valve GA5010SL30PT Illustrated Parts BreakdownKEY Part Description QTY Parts ListCisc Cisg Included In Hardware Kit International Warranty Information