Desa installation manual Thermostat Models FAS-3B and FAS-5B

Page 13

OWNER’S MANUAL

OPERATING

HEATER

Continued

THERMOSTAT MODELS FAS-3B AND FAS-5B

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas con- trol which has been under water.

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 1.

2.Make sure manual shutoff valve is fully open.

3.Push in control knob slightly and

turn clockwise to the OFF position. Be sure that the tempera- ture setting knob is set at the line between level 1 and level 7 (see Fig- ure 19).

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column 1. If you don’t smell gas, go to the next step.

 

 

PILOT

6

 

IGN

5

 

ON

 

7

 

4

1

OFF

 

 

3

2

 

Figure 19 - Dual Control for Thermostat Models FAS-3B and FAS-5B

 

Ignitor Electrode

Thermocouple

Pilot Burner

 

Figure 20 - Pilot

 

Temperature

Control

 

Setting Knob

Knob

FAS-3B

 

 

 

PILOT

 

3

4

ON

 

IGN

 

 

 

2

5

 

 

OFF

 

 

 

1

6

 

 

 

7

 

 

 

 

 

 

 

 

 

 

PILOT

 

5

6

ON

 

IGN

 

 

 

7

 

 

 

 

 

 

 

4

1

 

 

OFF

 

 

 

 

3

2

 

 

 

5.Push in and turn control knob coun-

terclockwise to PILOT po- sition. Press in control knob for five(5) seconds.

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, you may need to press in control knob for 30 seconds. This will allow air to bleed from the gas system.

6.Release downward pressure on con-

trol knob and turn clockwise to OFF position.

7.Press in control knob and turn coun-

terclockwise past IGN to PILOT (see Figure 19). This will cause the piezo ignitor to spark and light the pilot gas. Keep control knob depressed for 10 seconds before re- leasing. If needed, repeat steps 5 through 7 until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 15 through 17. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 14.

8 . When pilot is lit, turn the control knob to ON position (see Figure 21).

9.To select desired heating level, turn the temperature setting knob coun-

terclockwise between 1 and 7 (see Figure 21).

FAS-5B

ON

OFF

Figure 21 - Burner Patterns

Continued

105566

13

Image 13
Contents What to do if YOU Smell GAS Infrared VENT-FREE Natural GAS HeaterInfrared Natural GAS Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProducing Adequate Ventilation Fresh AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location Fresh AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Items InstallationLocating Heater Check GAS TypeMounting Bracket Installing Heater to WallRemoving Front Panel Of Heater Models FA-3B and FA-5B Methods For Attaching Mounting Bracket To WallAttaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket Typical Inlet Pipe Diameters Connecting to GAS SupplyPressure Testing Gas Supply Piping System For Your Safety Read Before LightingPressure Testing Heater Gas Connections Operating HeaterLighting Instructions Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS to ApplianceThermostat Models FAS-3B and FAS-5B Inspecting Burner Cleaning and MaintenanceObserved Problem Possible Cause Remedy TroubleshootingInfrared Natural GAS Heater Top Service Hints SpecificationsService Publications Technical Replacement PartsParts Centrals AccessoriesManual Shutoff Valve GA5010 FAN Kits UH1000FB and UHS1000FBIllustrated Parts Breakdown Burner Assembly ODS/Pilot AssemblyFA-3B KEY FA-3B Description Parts ListFA-5B KEY FA-5B Description FAS-3B ODS/Pilot Assembly Burner AssemblyKEY FAS-3B Description QTY FAS-5B KEY FAS-5B Description QTY International Warranty Information