INFRARED NATURAL GAS HEATER

OPERATING

HEATER

Continued

TO TURN OFF GAS TO

APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise to the PILOT position.

THERMOSTAT

CONTROL

OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The temperature set- ting knob can be set to any comfort level between 1 and 7.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.) Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 13.

2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 22 shows a correct pilot flame pattern. Figure 23 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 23

turn heater off (see To Turn Off Gas to Appliance)

seeTroubleshooting, pages 15 through 17

Pilot Burner

Thermocouple

Figure 22 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 23 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 24 shows a correct burner flame pattern. Figure 25 shows an incorrect burner flame pattern.

If pilot flame pattern is incorrect, as shown in Figure 25

turn heater off (see To Turn Off Gas to Appliance)

seeTroubleshooting, pages 15 through 17

Figure 24 - Correct Burner Flame Pattern

Bad Burner Pattern-Plaque GRH/OV 019

Figure 25 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before servicing.

CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, pet hair, etc.

ODS/PILOT AND BURNER ORIFICE

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

14

105566

Image 14
Contents Infrared VENT-FREE Natural GAS Heater What to do if YOU Smell GASSafety Information Infrared Natural GAS HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction Fresh AIR for Combustion and VentilationProducing Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Fresh AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Locating Heater InstallationInstallation Items Check GAS TypeRemoving Front Panel Of Heater Models FA-3B and FA-5B Installing Heater to WallMounting Bracket Methods For Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsAttaching Mounting Bracket To Wall Connecting to GAS Supply Typical Inlet Pipe DiametersPressure Testing Heater Gas Connections For Your Safety Read Before LightingPressure Testing Gas Supply Piping System Operating HeaterTo Select Heating Level Manual Lighting ProcedureLighting Instructions To Turn OFF GAS to ApplianceThermostat Models FAS-3B and FAS-5B Cleaning and Maintenance Inspecting BurnerTroubleshooting Observed Problem Possible Cause RemedyInfrared Natural GAS Heater Top Service Publications Technical SpecificationsService Hints Replacement PartsManual Shutoff Valve GA5010 AccessoriesParts Centrals FAN Kits UH1000FB and UHS1000FBFA-3B Burner Assembly ODS/Pilot AssemblyIllustrated Parts Breakdown Parts List KEY FA-3B DescriptionFA-5B KEY FA-5B Description ODS/Pilot Assembly Burner Assembly FAS-3BKEY FAS-3B Description QTY FAS-5B KEY FAS-5B Description QTY Warranty Information International