INFRARED NATURAL GAS HEATER
OPERATING
HEATER
Continued
LIGHTING
INSTRUCTIONS
1. | STOP! Read the safety information | |
| page 11, column 3. |
|
2. | Make sure manual shutoff valve is | |
| fully open. |
|
3. | Turn control knob clockwise | |
| to the OFF position. |
|
4. | Wait five minutes to clear out any | |
| gas. Then smell for gas, including | |
| near the floor. If you smell gas, | |
| STOP! Follow “B” in the safety in- | |
| formation page 11, column 3. If you | |
| don’t smell gas, go to the next step. | |
5. | Press in and turn control knob coun- | |
| terclockwise | to PILOT/IGN |
| position. Press in control knob for | |
| five(5) seconds (see Figure 18). | |
| Note: You may be running this heater | |
| for the first time after hooking up to | |
| gas supply. If so, you may need to press | |
| in control knob for 30 seconds. This will | |
| allow air to bleed from the gas system. | |
| • If control knob does not pop up when | |
| released, contact a qualified service | |
| person or supplier for repairs. | |
6. | Release downward pressure on con- | |
| trol knob and turn clockwise | |
| to OFF position. |
|
Figure 16 - Control Knob In The OFF Position
| Ignitor Electrode |
Thermocouple | Pilot Burner |
|
Figure 17 - Pilot
TO SELECT
HEATING LEVEL
WARNING: When running heater, set control knob at LOW, MEDIUM, or HIGH locked posi- tions. Never set control knob be- tween locked positions. Poor combustion and higher levels of carbon monoxide may result.
CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.
Slightlypressincontrolknobandturncoun-
terclockwise to the LOW, ME- DIUM, or HIGH positions (see Figure 18).
IMPORTANT: Release downward pres- sure while turning control knob. Control knob will lock at the desired position.
TO TURN OFF GAS TO
APPLIANCE
Shutting Off Heater
1.Turn control knob clockwise to the OFF position.
2.Turn off all electric power to the ap- pliance if service is to be performed.
Shutting Off Burner Only (pilot stays lit)
Turn control knob clockwise to the PILOT/IGN position.
MANUAL LIGHTING
PROCEDURE
1.Follow steps 1 through 5 under Light- ing Instructions.
2.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.
3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
7. Press in control knob and turn back |
to PILOT/IGN. This will cause the |
piezo ignitor to spark and light the |
pilot gas. If needed, repeat steps 5 |
through 7 until pilot lights. |
Note: If pilot does not stay lit, refer |
to Troubleshooting, pages 15 through |
17. Also contact a qualified service |
person or gas supplier for repairs. |
Until repairs are made, light pilot |
with match. To light pilot with match, |
see Manual Lighting Procedure. |
8 . Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.
Note: If pilot goes out, repeat steps 3 through 7.
Control |
|
|
Knob |
LOW
MED
HIGH
OFF
Figure 18 - Burner Patterns
12 | 105566 |