Desa VYM27NR/PR, FVFM27NR/PR Installing Logs, Pressure Testing Heater Gas Connections

Page 13

OWNER’S MANUAL

INSTALLATION

Continued

Pressure Testing Heater Gas Connections

1.Open equipment shutoff valve (see Fig- ure 15, page 12).

2.Open main gas valve located on or near gas meter for natural gas or open propane/LP supply tank valve.

3.Make sure control knob of heater is in the OFF position.

4.Check all joints from equipment shutoff valve to control valve (see Figure 16 or 17). Apply a noncorrosive leak de- tection fluid to gas joints. Bubbles forming show a leak.

5.Correct all leaks at once.

INSTALLING LOGS

WARNING: Failure to position the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, re- position logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

Burner

 

Logs

Ports

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 19 - Installing Log set (Top View)

Top Log (#2)

Peg

6.Light heater (see Operating Heater, pages 14 through 16). Check all other internal joints for leaks.

7.Turn off heater (see To Turn Off Gas to Appliance, page 15).

Equipment Shutoff Valve

Gas Meter

Control Valve

Location

Figure 16 - Checking Gas Joints for Natural Gas

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place bottom log (#1) on grate to fit as illustrated in Figure 18. Make sure open areas of log set line up with burner ports (see Figure 19). Log will fit securely on chassis. IMPORTANT: Make sure log does not cover any burner ports.

2.Facing front of unit, place top log (#2) onto the pegs in the center of the bot- tom log (see Figure 20).

3.Position log piece (#3) by aligning holes on underside with remaining pegs on bottom log (see Figure 21).

4.Place lava rock around base of heater.

Bottom Log (#1)

Figure 20 - Installing Top Log (#2)

Log Piece (#3)

Peg

Propane/LP

Equipment

 

 

Supply Tank

Shutoff Valve

 

 

 

 

 

Burner

 

 

 

Port

 

 

 

Figure 21 - Installing Log Piece (#3)

 

 

Grate

 

 

Control Valve Location

 

Burner

Figure 17 - Checking Gas Joints for

Chassis

Propane/LP Gas

 

 

 

 

 

Figure 18 - Installing Bottom Log (#1)

108382

13

For more information, visit www.desatech.com

Image 13
Contents FLAME-MAX OWNER’S Operation and Installation ManualVYM27NR/PR FVFM27NR/PR What to do if YOU Smell GASFLAME-MAX Unvented GAS LOG Heater Safety InformationRemote Control Product FeaturesAccessories Product IdentificationProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances Mantel Clearances Determining Minimum Mantel Clearance When using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Supply Connecting to GASChecking GAS Pressure Testing Gas Supply Piping SystemConnections Pressure Testing Heater Gas Connections Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS To Appliance Manual Lighting ProcedureOptional Remote Operation Pilot Flame Pattern Inspecting BurnersCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Specifications Wiring Diagram Replacement PartsService Hints Technical ServiceVYM27NR FVFM27NR VYM27PR FVFM27PR Illustrated Parts BreakdownParts Available not Shown Parts ListReceiver and HAND- Held Remote Control KIT Ghrc WALL-MOUNT Thermostat Switch GWMT1WALL-MOUNT ON/OFF Switch GWMS2 Cleaning KIT GCKOwners Registration Form Postage Required 108382 Warranty Information