FLAME-MAX®
UNVENTED GAS LOG HEATER
OPERATING
HEATER
Continued
IMPORTANT: This remote control has been specially engineered to take an air temperature sample ev- ery 5.5 minutes in the AUTO mode. It will not respond immediately to the temperature setting being turned up or down.
IMPORTANT: The
3.To turn the burner off, press the AUTO/ON/OFF button until OFF lights. The pilot will remain lit.
IMPORTANT: To turn the pilot off, manually turn the control knob on the heater to the OFF position.
INSPECTING
BURNERS
Check pilot flame pattern and burner flame patterns often.
PILOT FLAME PATTERN
Figure 27 shows a correct pilot flame pattern. Figure 28 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. When the thermo- couple cools, the heater will shut down.
Flame Adjustment Knob | Control Knob in | ||
On Position | |||
IH |
| F | PIL |
ON |
| O | |
O | F | T | |
|
| ||
OFF |
| O | |
|
| ||
|
| N | |
REMOTE |
|
| |
|
|
| |
LO |
|
|
|
If pilot flame pattern is incorrect, as shown in Figure 28
•turn heater off (see To Turn Off Gas to Appliance, page 15)
•see Troubleshooting, pages 18 through 20
Pilot Burner
Thermocouple
Selector Switch in Remote Position
(Optional Remote Control)
Figure 25 - Setting the Selector Switch, Control Knob, and Flame Adjustment Knob for Remote Operation
Figure 27 - Correct Pilot Flame Pattern (Propane/LP Pilot Shown)
Shows Temperature Setting
The Log Heater will Automatically Cycle between Pilot and the Heat Setting that has been Selected
Increases Room
Temperature in
AUTO Mode
Decreases Room
Temperature in
AUTO Mode
Turns Burners On or Off and Allows You to Choose the Auto Setting
Pilot Burner
Thermocouple
Figure 28 - Incorrect Pilot Flame Pattern (Propane/LP Pilot Shown)
Figure 26 - Thermostat Hand-Held Remote Control Unit Selections (GHRCTA only)
For more information, visit www.desatech.com | 16 | 108382 |