Continued

8.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: If pilot goes out, repeat steps 4 through 8.

9.Slightly push in and turn control

knob counterclockwise to the ON position.

10.Wait one minute and switch selector switch to the ON position to light burner. Note: AUTO is only func- tional when using GWMT1, or GWMS2 optional accessories.

11.Set flame adjustment knob to any level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the equip- ment shutoff valve.

WARNING: Make sure the se- lector switch is in the OFF position when you are away from home for long periods of time. Heater will come on automatically with selec- tor switch in the ON position.

Pilot Burner

Ignitor

 

Electrode

Figure 23 - Natural Gas Pilot

Pilot Burner

Ignitor

 

Electrode

Figure 24 - Propane/LP Gas Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise to the OFF position.

2a. Set selector switch in the OFF position.

2b. If Using Optional Hand-Held Re- mote: Set selector switch in the OFF position to prevent draining battery.

Shutting Off Burner Only (pilot stays lit)

You may shut off the burner and keep the pilot lit by doing one of the following:

1.Turn control knob clockwise to the PILOT position.

2.Use remote control manual OFF button.

3.Set selector switch in the OFF position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Light- ing Instructions, page 14.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, column 1.

OPTIONAL REMOTE

OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page 24). Follow instructions included with the remote control.

Thermostat Control Operation

(Optional GHRCTA Series Only) The thermostat control setting on the remote control unit can be set to any comfort level between WARMER and COOLER. The burner will turn on and off automati- cally to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

For wall thermostat operation, follow in- structions supplied with thermostat ac- cessory GWMT1. For wall switch opera- tion follow instructions supplied with GWMS2.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 14.

1.After lighting, let pilot flame burn for about one minute. Turn control knob to ON position. Adjust flame adjust- ment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position. NOTE: The burner may light if hand-held remote ON button was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the se- lector switch in the REMOTE posi- tion when the pilot is not lit. This will drain the battery.

IMPORTANT: Be sure to press the ON/OFF buttons on the hand held remote control unit for up to 3 sec- onds to assure proper operation.

GHRC Series Operation:

2a. Press the ON/OFF button to turn the burner on and off. When turning burner off, the pilot will remain lit.

GHRCTA Series Operation

2b. Press the AUTO/ON/OFF button on the hand-held remote control (see Figure 26, page 16). The lights to the left of the button will show AUTO, ON, or OFF.

In the ON mode, the burners will ignite. The heater is in manual mode when ON is lit.

In the AUTO mode, the thermostat in the hand-held remote unit con- trols the room temperature. To in- crease the room temperature, press the top arrow of the TEMP button. To lower the room temperature, press the bottom arrow of the TEMP button. At higher settings the heater will run longer.

Continued

108382

15

For more information, visit www.desatech.com

Image 15
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualFLAME-MAX VYM27NR/PR FVFM27NR/PRFLAME-MAX Unvented GAS LOG Heater Safety InformationProduct Identification Product FeaturesRemote Control AccessoriesConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials InstallationInstallation Clearances Check GAS TypeMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When using a HoodMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Supply Connecting to GASPressure Testing Gas Supply Piping System Checking GASConnections Pressure Testing Heater Gas Connections Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Manual Lighting Procedure To Turn OFF GAS To ApplianceOptional Remote Operation Pilot Flame Pattern Inspecting BurnersCleaning and Maintenance Observed Problem Possible Cause TroubleshootingObserved Problem Possible Cause Remedy Gas leak. See Warning statement at Technical Service Wiring Diagram Replacement PartsSpecifications Service HintsVYM27NR FVFM27NR VYM27PR FVFM27PR Illustrated Parts BreakdownParts Available not Shown Parts ListCleaning KIT GCK WALL-MOUNT Thermostat Switch GWMT1Receiver and HAND- Held Remote Control KIT Ghrc WALL-MOUNT ON/OFF Switch GWMS2Owners Registration Form Postage Required 108382 Warranty Information