OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | ||
Heater produces a clicking/ticking noise | 1. | Metal expanding while heating or con- | 1. | This is common with most heaters. If |
just after burner is lit or shut off |
| tracting while cooling |
| noise is excessive, contact qualified ser- |
|
|
|
| vice person |
|
|
|
|
|
Heater produces unwanted odors | 1. | Heater burning vapors from paint, hair | 1. | Open window and ventilate room. Stop |
|
| spray, glues, cleaners, chemicals, new |
| using odor causing products while heater |
|
| carpet, etc. (See IMPORTANT state- |
| is running |
|
| ment above) |
|
|
| 2. | Gas leak. See Warning statement at | 2. | Locate and correct all leaks (see Check- |
|
| top of page |
| ing Gas Connections, page 12) |
|
|
|
|
|
Heater shuts off in use (ODS operates) | 1. | Not enough fresh air is available | 1. | Open window and/or door for ventilation |
| 2. | Low line pressure | 2. | Contact local natural or propane/LP gas |
| 3. | ODS/pilot is partially clogged |
| company |
|
|
| 3. | Clean ODS/pilot (see Cleaning and |
|
|
|
| Maintenance, page 17) |
|
|
|
|
|
Gas odor even when control knob is in OFF | 1. | Gas leak. See Warning statement at | 1. | Locate and correct all leaks (see Check- |
position |
| top of page |
| ing Gas Connections, page 12) |
| 2. | Control valve defective | 2. | Replace control valve |
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between control valve | 1. | Take apart gas tubing and remove for- |
|
| and burner |
| eign matter |
| 2. | Gas leak. See Warning statement at | 2. | Locate and correct all leaks (see Check- |
|
| top of page |
| ing Gas Connections, page 12) |