TROUBLESHOOTING

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Remote does not function (Remote-Ready Models Only)

1.Battery is not installed. Battery power is low

1.Replace 9-volt batteries in receiver and remote control

Heater produces a clicking/ticking noise just after burners are lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Low fuel supply (propane/LP only)

 

3.

Gas leak. See Warning statement

 

 

at top of page

1.Open window to ventilate room. Stop us- ing odor causing products while heater is running

2.Refill supply tank (propane/LP only)

3.Locate and correct all leaks (see Check- ing Gas Connections, page 14)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural or propane/LP gas

 

 

 

 

company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 23)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement

1.

Locate and correct all leaks (see Check-

position

 

at top of page

 

ing Gas Connections, page 14)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement

 

 

at top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 14)

For..com

107070-01F

Image 26
Contents Unvented VENT-FREE GAS LOG Heater What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Product Identification Flame-MaxBirch LogsLocal Codes Optional Remote Control AccessoriesProduct Features UnpackingDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building LOG Sizing Requirements InstallationCheck GAS Type If Not Using Mantel Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Installation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various StandardLogs, pages 15 Connecting to GAS Supply External Regulator With Vent Pointing DownPressure Testing gas Supply Piping system Checking GAS ConnectionsInstalling Logs Pressure Testing Heater Gas ConnectionsInstalling Vintage Oak One-Piece Log Set Operating Heater Lighting InstructionsThermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterREMOTE-READY Models For Your Safety Read Before Lighting Variable Control OperationFlame Adjustment Knob Optional HAND-HELD Remote Operation ON/OFF Series Model GhrcbPilot Flame Pattern Inspecting BurnersThermostat Series Model Ghrctb Burner Primary AIR Holes Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Main BurnerTroubleshooting Observed Problem Possible Cause RemedyClean burner see Cleaning and Mainte Gas leak. See Warning statement Thermostat-Controlled Models Only Optional Positioning of Thermostat Sensing BulbFor Masonry and FACTORY-BUILT Metal Fireplace Specifications Replacement Parts Wiring DiagramService Hints Technical ServiceODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVYS24NA, H24N, VYS30PA VYS30NA Parts List Variable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG ModelsVYD36PA Parts Available not Shown Variable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG AND1B ODS Pilot Natural GasBurner Retainer Spring VYD24NTA, VYD30PTA and VYD30NTA THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models VYD36PRA and HD36PR REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models VYD36NRA and HD36NR Parts List VYBD24NR, VYBD30PR and VYBD30NR REMOTE-READY FLAME-MAXBIRCH LOG Models Accessories Owners Registration Form Postage Required 107070-01F Warranty Information