Desa V installation manual REMOTE-READY FLAME-MAXBIRCH LOG Models

Page 43

PARTS LIST

Models VYBD18PR, VYBD18NR, VYBD24PR, VYBD24NR, VYBD30PR and VYBD30NR

43

PARTS LIST

REMOTE-READY

FLAME-MAX®BIRCH LOG MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.

KEY

 

 

PART NUMBER FOR

 

 

 

 

NO.

VYBD18PR

VYBD18NR

VYBD24PR

VYBD24NR

VYBD30PR

VYBD30NR

DESCRIPTION

QTY.

1

103520-01

103520-01

103336-01

103336-01

103522-01

103522-01

Log, Birch

1

2

103778-01

103779-01

103778-01

103779-01

103778-01

103779-01

ODS Pilot

1

3

098249-01

098249-01

098249-01

098249-01

098249-01

098249-01

ODS Nut

2

4

104422-02

104422-01

103342-02

103342-01

103342-02

103342-01

Burner Outlet Tube

1

5

098264-02

098264-02

098264-02

098264-02

098264-02

098264-02

Male Connector

1

6

111124-01

111124-01

111124-01

111124-01

111124-01

111124-01

Burner Retainer Spring

1

7

099056-19

099056-26

099056-17

099056-16

099056-17

099056-16

Burner Orifice Injector

1

8

099998-01

099998-01

099998-01

099998-01

099998-01

099998-01

Switch

1

9

102980-01

102980-01

102772-01

102772-01

102772-01

102772-01

Burner

1

10

099387-13

099387-15

099387-09

099387-12

099387-09

099387-12

Pilot Tube

1

11

103781-02

103781-01

103781-02

103781-01

103781-02

103781-01

Gas Control Valve

1

12

103345-02

103345-02

103345-01

103345-01

103345-01

103345-01

Lower Bracket

1

13

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

Screw, #8 x .38

4

14

104384-01

104384-01

102775-06CK

102775-06CK

102775-08CK

102775-08CK

Painted Base Assy

1

15

098271-10

098271-10

098271-10

098271-10

098271-10

098271-10

Ignitor Cable

1

16

102445-01

102445-01

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor

1

17

103587-02

103587-02

103587-02

103587-02

103587-02

103587-02

Plate, Switch

1

18

104099-01

104099-01

104099-01

104099-01

104099-01

104099-01

Heat Shield

1

19

098304-01

098304-01

098304-01

098304-01

098304-01

098304-01

Screw

2

20

103784-02

103784-02

103784-02

103784-02

103784-02

103784-02

Flame Adjustment Knob

1

21

103784-01

103784-01

103784-01

103784-01

103784-01

103784-01

Off-Pilot-On Knob

1

22

M12461-26

M12461-26

M12461-26

M12461-26

M12461-26

M12461-26

Screw, Hex Slt Wsr 10-32 x .38

4

23

100609-01

100609-01

100609-01

Pilot Tube

 

 

 

 

 

 

 

 

(Regulator to Pilot [NG Only])

1

24

099918-02

099918-02

099918-02

Pilot Regulator (NG Only)

1

25

103284-02

103284-02

103284-02

103284-02

103284-02

103284-02

Wiring Harness

1

 

 

 

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

 

 

 

 

 

 

 

 

 

 

100563-01

100563-01

100563-01

100563-01

100563-01

100563-01

Warning Plate

1

 

103877-01

103877-01

103877-01

103877-01

103877-01

103877-01

Lighting Instructions Plate

1

 

100565-01

100565-01

100565-01

100565-01

100565-01

100565-01

Warning Plate Fastener

1

 

100639-01

100639-01

100639-01

100639-01

100639-01

100639-01

Caution Decal

1

 

101137-02

101137-02

101137-02

101137-02

101137-02

101137-02

Hardware Kit

1

 

GA6060

GA6060

GA6060

GA6060

GA6060

GA6060

Lava Rock

1

 

 

 

 

 

 

 

 

 

For morevisit www..com

107070-01F

Image 43
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Flame-MaxBirch Logs Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesConfined and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Check GAS Type InstallationLOG Sizing Requirements Minimum Noncombustible Material Clearances If Not Using MantelFloor Clearances Mantel ClearancesDetermining Minimum Mantel Clearance Area of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededLogs, pages 15 External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsInstalling Vintage Oak One-Piece Log Set Lighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob ON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationThermostat Series Model Ghrctb Inspecting BurnersPilot Flame Pattern Main Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesObserved Problem Possible Cause Remedy TroubleshootingClean burner see Cleaning and Mainte Gas leak. See Warning statement For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbThermostat-Controlled Models Only Specifications Technical Service Wiring DiagramService Hints Replacement PartsVYS24NA, H24N, VYS30PA VYS30NA Illustrated Parts BreakdownODS Pilot Natural Gas ODS Pilot Propane/LP Variable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVYD36PA Parts Available not Shown ODS Pilot Natural Gas Variable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG AND1BBurner Retainer Spring VYD24NTA, VYD30PTA and VYD30NTA THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models VYD36PRA and HD36PR REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models VYD36NRA and HD36NR Parts List VYBD24NR, VYBD30PR and VYBD30NR REMOTE-READY FLAME-MAXBIRCH LOG Models Accessories Owners Registration Form Postage Required 107070-01F Warranty Information