Desa V, T installation manual Burner Retainer Spring

Page 35

PARTS LIST

Models VYD18NA, VYBD18N, VYD24NA, VYBD24N, VYD30NA, VYBD30N and VYD36NA

35

PARTS LIST

VARIABLE MANUALLY-CONTROLLED

FLAME-MAX®GOLDEN OAK LOG AND

BIRCH LOG MODELS

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual.

KEY

 

 

PART NUMBER FOR

 

 

 

 

 

NO.

VYD18NA

VYBD18N

VYD24NA

VYBD24N

VYD30NA

VYBD30N

VYD36NA

DESCRIPTION

QTY.

1A

105268-01

105268-02

105268-03

107027-01

Log, Golden Oak

1

1B

103520-01

103336-01

103522-01

Log, Birch

1

2

098276-01

098276-01

098276-01

098276-01

098276-01

098276-01

098276-01

Hex Head Plug,

 

 

 

 

 

 

 

 

 

1/8" NPT

1

3

098249-01

098249-01

098249-01

098249-01

098249-01

098249-01

098249-01

Nut, M5

2

4

102775-04CK

102775-04CK

102775-01CK

102775-01CK

102775-03CK

102775-03CK

102775-03CK

Painted Base

 

 

 

 

 

 

 

 

 

Assembly

1

5

102844-02

102844-02

102844-01

102844-01

102844-01

102844-01

102844-01

Lower Bracket

1

6

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

M11084-38

Screw, Hex Head

8

 

 

 

 

 

 

 

 

(#8-18 x .38)

 

7

098867-14

098867-14

098867-14

098867-14

098867-14

098867-14

098867-14

Gas Regulator

1

8

102798-01

102798-01

102798-01

102798-01

102798-01

102798-01

102798-01

Inlet Tube

1

9

102779-03

102779-03

102779-01

102779-01

102779-01

102779-01

102779-01

Outlet Burner Tube

1

10

099056-26

099056-26

099056-16

099056-16

099056-16

099056-16

099056-16

Burner Orifice

 

 

 

 

 

 

 

 

 

Injector

1

11

111124-01

111124-01

111124-01

111124-01

111124-01

111124-01

111124-01

Burner Retainer Spring

1

12

102980-01

102980-01

102772-01

102772-01

102772-01

102772-01

102772-01

Burner

1

13

102568-07

102568-07

102568-05

102568-05

102568-05

102568-05

102568-05

Control Valve

1

14

098508-01

098508-01

098508-01

098508-01

098508-01

098508-01

098508-01

Valve Retainer Nut

1

15

098354-01

098354-01

098354-01

098354-01

098354-01

098354-01

098354-01

Control Knob

1

16

102445-01

102445-01

102445-01

102445-01

102445-01

102445-01

102445-01

Piezo Ignitor

1

17

099387-08

099387-08

099387-08

099387-08

099387-08

099387-08

099387-08

Pilot Tube

1

18

098271-10

098271-10

098271-10

098271-10

098271-10

098271-10

098271-10

Ignitor Cable

1

19

104285-01

104285-01

104285-01

104285-01

104285-01

104285-01

104285-01

ODS Pilot

1

 

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

100563-01

101055-02

100565-01

100639-01

101449-04

101137-02 GA6060

Warning Plate

Lighting Instructions

Plate

Warning Plate

Fastener

Caution Decal

Control Position

Decal

Hardware Kit

Lava Rock

1

1

1

1

1

1

1

For morevisit www..com

107070-01F

Image 35
Contents What to do if YOU Smell GAS Unvented VENT-FREE GAS LOG HeaterSafety Information Table of ContentsSafety Information Flame-MaxBirch Logs Product IdentificationUnpacking Optional Remote Control AccessoriesProduct Features Local CodesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined and Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building LOG Sizing Requirements InstallationCheck GAS Type Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Mantel ClearancesFloor Clearances Area of Various Standard Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededLogs, pages 15 External Regulator With Vent Pointing Down Connecting to GAS SupplyChecking GAS Connections Pressure Testing gas Supply Piping systemPressure Testing Heater Gas Connections Installing LogsInstalling Vintage Oak One-Piece Log Set Lighting Instructions Operating HeaterShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS To Appliance Thermostat Control OperationVariable Control Operation REMOTE-READY Models For Your Safety Read Before LightingFlame Adjustment Knob ON/OFF Series Model Ghrcb Optional HAND-HELD Remote OperationPilot Flame Pattern Inspecting BurnersThermostat Series Model Ghrctb Main Burner Cleaning MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesObserved Problem Possible Cause Remedy TroubleshootingClean burner see Cleaning and Mainte Gas leak. See Warning statement Thermostat-Controlled Models Only Optional Positioning of Thermostat Sensing BulbFor Masonry and FACTORY-BUILT Metal Fireplace Specifications Technical Service Wiring DiagramService Hints Replacement PartsODS Pilot Natural Gas ODS Pilot Propane/LP Illustrated Parts BreakdownVYS24NA, H24N, VYS30PA VYS30NA Variable MANUALLY-CONTROLLED FLAME-MAXVINTAGE OAK LOG Models Parts ListVYD36PA Parts Available not Shown ODS Pilot Natural Gas Variable MANUALLY-CONTROLLED FLAME-MAXGOLDEN OAK LOG AND1BBurner Retainer Spring VYD24NTA, VYD30PTA and VYD30NTA THERMOSTAT-CONTROLLED FLAME-MAXGOLDEN OAK LOG Models VYD36PRA and HD36PR REMOTE-READY FLAME-MAXGOLDEN OAK LOG Models VYD36NRA and HD36NR Parts List VYBD24NR, VYBD30PR and VYBD30NR REMOTE-READY FLAME-MAXBIRCH LOG Models Accessories Owners Registration Form Postage Required 107070-01F Warranty Information