Fisher & Paykel OR24SDMBGX installation instructions GAS Connection Specification, Connector

Page 11

2b

GAS CONNECTION SPECIFICATION

Range

manifold

1/2” G cylindrical (ISO 228-1) male

Manifold male pipe fitting

Gasket

 

1/2” G cylindrical

 

 

 

 

(ISO 228-1) female

Extension pipe female pipe fitting

 

Extension

 

pipe

Extension

 

pipe male

1/2” G cylindrical

pipe fitting

(ISO 228-1) male

Gasket

1/2” G cylindrical

 

(ISO 228-1) female

1/2” NPT (conical)

Connector

male

 

1/2” NPT female

Pressure regulator

1/2” NPT female

To range

To main

connection

Arrow

WARNING: check the right positioning of the gas regulator. The arrow on the back of the gas regulator must be oriented toward the connector.

Fig. 2.4

11

Image 11 Contents
Installation instructions Instructions dinstallation ALL Ranges can TIP For Installer only Installation Instructions Air Supply and Ventilation Replacement PartsElectrical Grounding Instructions Electrical RequirementGAS and Electric Connection InstallationProximity to Side Cabinets Assembling the Backguard It is mandatory to install the backguardLevelling the Range ANTI-TIP Stability Device Installation InstructionsPressure Regulator Gas connectionManual Shut-off Valve fig Explosion HazardPressure Regulator Installation Step Connector GAS Connection SpecificationRigid Pipe Connections Leak TestingFlexible Connections To set the pressure regulator Setting the Pressure Regulator .6bConversion to LP/PROPANE GAS Injectors Table Operations to be Performed When Substituting the InjectorsSetting the Burner Minimum Valves may vary Broil Burner Oven BurnerAdjustment of the Oven Burner Minimum Recommended ground method Electrical connectionWiring Diagram Page Avertissement ’INTENTION DE L’INSTALLATEUR Seulement Avertissement Instructions D’INSTALLATIONAlimentation d’air et ventilation Instructions DE Mise À LA TerrePièces DE Rechange Exigences électriquesRaccordements Électrique ET AU GAZ A1installationProximité DES Armoires Montage DU Dosseret ’installation du dosseret est obligatoireMise À Niveau DE LA Cuisinière Risque d’explosion Raccordement au gazRobinet d’arrêt manuel fig Régulateur de pressionFermer Installation DU Régulateur DE Pression ÉtapeJoint Spécification DU Raccordement AU GAZVérification de l’absence de fuite Raccords flexiblesRaccords de tuyaux rigides Pour régler le régulateur de pression Conversion AU GAZ PROPANE/GPLRéglage DU Régulateur DE Pression .6b Réglage Minimum DU Brûleur Les robinets peuvent varier Tableau DES InjecteursOpérations À Effectuer Pour Remplacer LES Injecteurs Brûleur du gril Brûleur du fourRée Réglage Minimum DU Brûleur DU FourRaccordement électrique Méthode de mise à la terre recommandéeSchéma DE Câblage Page Page Page US CA
Related manuals
Manual 48 pages 52.98 Kb