Goodman Mfg GPG13 installation manual 0140G00089

Page 34

 

 

 

 

 

 

 

 

 

GPG13(48,60)4A WIRING DIAGRAM

 

 

 

 

 

 

 

 

 

 

HIGH VOLTAGE!

 

 

 

 

 

 

 

 

 

 

 

 

 

 

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS

 

 

 

 

 

 

 

 

 

UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO

 

 

 

 

 

 

 

 

 

DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

L1

 

 

 

SUPPLY VOLTAGE

 

 

L2

 

 

L3

COMPONENT LEGEND

FACTORY WIRING

 

 

 

 

 

460/3/60

 

 

 

 

 

 

 

ALS

AUXILLARY LIMIT SWITCH

LINE VOLTAGE

 

 

 

 

 

CH

 

 

 

 

 

 

 

 

 

 

 

 

NOTE 2

 

 

 

 

 

 

COMP

COMPRESSOR

LOW VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T2

C

 

 

 

 

 

CM

CONDENSER MOTOR

OPTIONAL HIGH VOLTAGE

 

C

T1

 

 

T2

 

L2

 

 

 

C

CONTACTOR

 

 

L1

T1 COMP

 

 

 

 

 

 

CH

CRANKCASE HEATER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T3

 

 

 

 

 

 

L3

EM

EVAPORATOR MOTOR

FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

T3

C

 

 

 

F

FUSE

HIGH VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FC

CM

 

 

 

 

 

 

FC

FAN CAPACITOR

LOW VOLTAGE

 

 

 

 

 

 

 

 

 

 

 

 

FS

FLAME SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GND

EQUIPMENT GROUND

WIRE CODE

 

 

 

 

H1

H4

 

 

 

 

VMR

 

 

GV

GAS VALVE

BK

BLACK

 

 

 

 

 

 

 

 

 

 

 

 

IIC

INTEGRATED IGNITION CONTROL

 

 

EM

 

 

TR

 

 

 

 

 

 

BL

BLUE

 

 

 

 

 

 

 

 

 

 

 

 

 

L

 

SEE NOTE 7

 

 

 

 

 

IGN

IGNITOR

 

 

X4

 

VM

3

1

 

BR

BROWN

 

 

N

 

 

X1

 

 

 

 

 

 

 

LS

LIMIT SWITCH

GR

GREEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

 

1

 

 

 

 

 

PLF

FEMALE PLUG/CONNECTOR

OR

ORANGE

 

 

 

 

 

 

 

 

 

 

 

PS

PRESSURE SWITCH

 

 

 

 

 

 

 

TR

 

 

 

 

 

PK

PINK

 

NOTE 6

 

 

 

 

NOTE 6

 

 

RS

ROLLOUT SWITCH

PU

PURPLE

 

 

 

 

 

 

 

 

L1

 

 

 

IGN

 

IIC

L2

TR

TRANSFORMER

RD

RED

 

 

 

 

 

FS

 

FS

 

 

 

VM

VENT MOTOR

WH

WHITE

 

F

 

 

 

 

 

T5

 

 

 

VMR

VENT MOTOR RELAY

YL

YELLOW

 

 

 

C

 

 

 

 

T4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

 

 

 

 

 

 

 

 

 

H

 

 

 

 

EM

 

 

NOTES

 

 

 

 

 

 

 

 

 

 

 

T3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

D1

 

 

 

T2 T1

 

 

 

1. REPLACEMENT WIRE MUST BE THE SAME SIZE AND TYPE OF

 

 

 

 

 

 

 

 

 

 

 

 

 

INSULATION AS ORIGINAL.(USE COPPER CONDUCTOR ONLY).

 

4

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

LS

VMR

 

 

 

 

2. CRANKCASE HEATER NOT SUPPLIED ON ALL UNITS.

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3. FOR DIFFERENT THAN FACTORY SPEED TAP. CHANGE COOLING

 

 

 

 

 

 

 

ALS

 

 

 

 

 

 

 

 

 

IIC

 

3

 

RS

 

GV

 

 

 

SPEED AT MOTOR T4 AND T5 TERMINALS. CHANGE HEATING

 

 

 

 

 

 

 

 

 

 

 

SPEED AT MOTOR T1, T2 AND T3 TERMINALS.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6

 

PS

 

 

 

 

 

 

COOLING SPEED (YELLOW WIRE)

HEATING SPEED (WHITE WIRE)

 

 

 

 

 

 

 

 

 

 

 

 

T4 - LOW SPEED

T1 - LOW SPEED

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

ECON

 

 

 

 

 

 

 

 

T5 - HIGH SPEED

T2 - MED. SPEED

 

 

 

 

 

 

 

 

 

 

 

 

 

 

9

 

7

 

10

12

 

 

 

 

 

 

 

 

 

T3 - HIGH SPEED

 

 

 

 

 

 

11

 

 

 

C

 

 

 

4. ACCESSORY ECONOMIZER PLUG (ON SELECT MODELS) ADJACENT

 

 

 

 

 

 

 

 

 

 

 

TO BLOWER HOUSING IN RETURN AIR COMPARMENT.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

NOTE

 

 

 

5. USE COOPER CONDUCTORS ONLY.

 

 

 

 

 

 

 

 

 

 

 

6

5

4

6. L1 AND L2 ON ICC CONTROL IS 24V INPUT.

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

PLF

2

1

7. STEPDOWN TRANSFORMER

 

 

R

 

G

 

W

Y1

Y2

Y

C

 

3

 

 

 

 

 

 

 

 

460V PRIMARY INPUT & 240V SECONDARY OUTPUT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TO THERMOSTAT

 

 

 

 

 

 

 

 

 

 

USE NEC CLASS 2 WIRE.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

460/3/60

 

INSTALLER/SERVICEMAN

 

 

 

 

 

THERMOSTAT FIELD WIRING

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

THE STATUS LIGHT ON THE FURNACE CONTROL MAY BE USED AS A GUIDE TO

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

TROUBLESHOOTING THIS APPLIANCE. STATUS LIGHT CODES ARE AS FOLLOWS:

NO ECONOMIZER

 

 

 

 

 

 

 

 

2 STAGE COOLING

 

 

 

 

 

 

 

 

 

STATUS LIGHT

EQUIP. STATUS

CHECK

 

 

WH

 

 

 

 

 

 

W

 

 

WH

 

 

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ON

NORMAL OPERATION

-

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

GR

 

 

 

 

 

 

G

 

 

GR

 

 

 

 

 

 

 

 

G

OFF

NO POWER OR

CHECKINPUT POWER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

INTERNAL CONTROL

CHECK FUSE ONCONTROL

 

 

RD

 

 

 

 

 

 

R

 

 

RD

 

 

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

FAULT

REPLACE CONTROL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1 BLINK

IGNITION FAILURE

GAS FLOW

 

 

YL

 

 

 

 

 

 

Y

 

 

PU

 

 

 

 

 

 

 

 

Y1

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OR

GAS PRESSURE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN ROLLOUT

GAS VALVE

 

 

BL

 

 

 

 

 

 

C

 

 

YL

 

 

 

 

 

 

 

 

Y2

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

FLAME SENSOR

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

C

 

OR

FLAME ROLLOUT

 

 

 

 

 

 

 

 

 

 

 

 

BL

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN AUX. LIMIT

BAD SWITCH

 

WITH ECONOMIZER OPTION

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

SWITCH

AUX. LIMIT OPEN

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2 BLINKS

PRESSURE SWITCH

CHECK

 

 

WH

 

 

 

 

 

 

W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OPEN

PRESSURE SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3 BLINKS

PRESSURE SWITCH CLOSED

CHECK

 

 

GR

 

 

 

 

 

 

G

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WITHOUT INDUCER ON

PRESSURE SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

4 BLINKS

OPEN LIMIT SWITCH

MAIN LIMIT OPEN

 

 

RD

 

 

 

 

 

 

R

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BAD SWITCH

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

5 BLINKS

FALSE FLAME SENSED

STICKING GAS VALVE

 

 

PU

 

 

 

 

 

 

Y

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6 BLINKS

COMPRESSOR

3 MIN. COMP.

 

 

BL

 

 

 

 

 

 

C

 

 

 

 

 

 

 

0140G00089

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

OUTPUT DELAY

ANTI-CYCLE TIMER

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wiring is subject to change. Always refer to the wiring diagram on the unit for the most up-to-date wiring.

34

Image 34
Contents GPG13 Ansi Z21.47CSA-2.3 Central FurnacesIndex Replacement Parts Safety InstructionsOutside Slab Installation Unit LocationRoof Curb Installation Rooftop InstallationGeneral Information Rigging Rigging DetailsGAS Piping Natural Gas ConnectionProper Piping Practice GAS Piping ChecksPropane Gas Pipe Sizing Low Voltage Wiring Electrical WiringTypical Propane Gas Piping Typical Thermostat and Unit 24 V Wiring Hookup Y2 C R Y1 W GFilter Installation Duct Cover Installation Down Discharge ApplicationsCirculating AIR and Filters Condensate Drain VentingNormal Sequences of Operation PG1348,60***1A only STARTUP, ADJUSTMENTS, and ChecksBe removed before operating unit Heat Anticipator Setting Rollout Protection ControlWhite-Rodgers Model 36F22 With Power And Gas OffWith Power And Gas On White-Rodgers 36G22 Gas Supply And Manifold CheckMain Burner Flame Check Temperature Rise CheckBlower Speed Adjustments External Static Pressure CheckTroubleshooting Short Cycle Compressor Delay Pressure Switch Stuck OpenPressure Switch Stuck Closed Internal Control FailureMaintenance Flame SensorFunctional Parts List Accessories and Functional PartsManifold Assembly Burner FlameCooling Timing Chart Ignition Control Diagnostic Indicator ChartHeating Timing Chart Circulator BlowerAppendix Unit Dimensions GPG1324,30,36,421A Wiring Diagram GPG1324,30,36,421A Wiring Diagram GPG13481A Wiring Diagram B4312004 Rev. a GPG13601A Wiring Diagram B4312005 Rev. a GPG13363A Wiring Diagram 0140G00085P GPG1348,603A Wiring Diagram Comp0140G00087 GPG13364A Wiring Diagram GND Comp0140G00088 GPG1348,604A Wiring Diagram 0140G00089 GPG1348,601B Wiring Diagram INSTALLER/SERVICEMAN Thermostat Field Wiring Minimum Clearances Recommended Filter SizesThis page Left Blank Intentionally This page Left Blank Intentionally That’s why we know. . .There’s No Better Quality Quality Makes the Difference

GPG13 specifications

Goodman Manufacturing is a prominent name in the HVAC industry, known for providing high-quality heating and cooling systems. Among their diverse lineup, the Goodman GPG13 stands out as a reliable packaged gas/electric unit. This model is particularly designed for residential and light commercial applications, ensuring a perfect blend of efficiency, comfort, and affordability.

One of the primary features of the Goodman GPG13 is its energy efficiency. The unit has a Seasonal Energy Efficiency Ratio (SEER) rating that helps homeowners reduce their energy costs while providing optimal cooling performance during warmer months. With a cooling capacity ranging from 2.5 to 5 tons, it effectively meets the cooling requirements of various sizes of homes or commercial spaces.

The Goodman GPG13 employs advanced technology to guarantee reliable operation. Its quiet operation is a significant advantage, thanks to the sound-dampening design of the unit’s compressor and fan. Moreover, the unit is equipped with a high-efficiency scroll compressor, which is known for its durability and consistent performance. This technology not only enhances the unit’s longevity but also ensures that homeowners enjoy a peaceful indoor environment.

In terms of construction, the Goodman GPG13 is built to last. The unit features a heavy-gauge galvanized steel cabinet with a powder-coated finish, which protects it from the elements and corrosion. This sturdy design ensures that the GPG13 can withstand various environmental conditions without compromising performance. Additionally, it has an easy-access control panel, simplifying maintenance and servicing tasks.

Another noteworthy characteristic of the Goodman GPG13 is its environmentally friendly refrigerant, R-410A. Unlike older refrigerants, R-410A has a lower environmental impact and contributes to ozone layer protection. This focus on environmental responsibility is essential in today’s green-conscious society and reflects Goodman’s commitment to sustainable practices.

The GPG13 is also equipped with a reliable multi-speed blower motor that enhances comfort by providing consistent airflow throughout the space. This capability allows homeowners to maintain desired temperatures while maximizing energy savings.

Overall, the Goodman GPG13 packaged gas/electric unit is an excellent choice for those seeking efficiency, durability, and comfort in their heating and cooling systems. With its range of advanced features and technologies, it stands as a testament to Goodman Manufacturing's dedication to quality and customer satisfaction in HVAC solutions.