Goodman Mfg ANSI Z21.47CSA-2.3 installation instructions High Voltage, General Information

Page 3
0140L00106 REV C

WARNING

THIS PRODUCT CONTAINS OR PRODUCES A CHEMICAL OR CHEMICALS WHICH MAY CAUSE SERIOUS ILLNESS OR DEATH AND WHICH ARE KNOWN TO THE STATE OF CALIFORNIA TO CAUSE CANCER, BIRTH DEFECTS OR OTHER REPRODUCTIVE HARM.

WARNING

TO AVOID PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DO NOT USE THIS UNIT IF ANY PART HAS BEEN UNDER WATER. IMMEDIATELY CALL A QUALIFIED SERVICE TECHNICIAN TO INSPECT THE FURNACE AND TO REPLACE ANY PART OF THE CONTROL SYSTEM AND ANY GAS CONTROL HAVING BEEN UNDER WATER.

WARNING

THIS UNIT MUST NOT BE USED AS A CONSTRUCTION HEATERDURING THE FINISHING PHASES OF CONSTRUCTION ON A NEW STRUCTURE. THIS TYPE OF USE MAY RESULT IN PREMATURE FAILURE OF THE UNIT DUE TO EXTREMELY LOW RETURN AIR TEMPERATURES AND EXPOSURE TO CORROSIVE OR VERY DIRTY ATMOSPHERES.

WARNING

HIGH VOLTAGE !

DISCONNECT ALL POWER BEFORE SERVICING OR INSTALLING THIS UNIT. MULTIPLE POWER SOURCES MAY BE PRESENT. FAILURE TO DO SO MAY CAUSE PROPERTY DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

TO PREVENT THE RISK OF PROPERTY DAMAGE, PERSONAL INJURY OR DEATH, DO NOT STORE COMBUSTIBLE MATERIALS OR USE GASOLINE OR OTHER FLAMMABLE LIQUIDS OR VAPORS IN THE VICINITY OF THIS APPLIANCE.

WARNING

HIGH VOLTAGE!

INSTALLATION AND REPAIR OF THIS UNIT SHOULD BE PERFORMED ONLY BY INDIVIDUALS MEETING (AT A MINIMUM) THE REQUIREMENTS OF AN “ENTRY LEVEL TECHNICIANAS SPECIFIED BY THE AIR CONDITIONING, HEATING, AND REFRIGERATION INSTITUTE (AHRI). ATTEMPTING TO INSTALL OR REPAIR THIS UNIT WITHOUT SUCH BACKGROUND MAY RESULT IN PRODUCT DAMAGE, PERSONAL INJURY OR DEATH.

WARNING

CARBON MONOXIDE POISONING HAZARD

Failure to keep this compartment closed except when servicing could result in carbon monoxide poisoning or death.

This compartment must be closed except when servicing.

DANGER

RISQUE D'EMPOISONNEMENT AU

MONOXYDE DE CARBONE

Si ce compartiment n'est pas ferme en tout temps, sauf en cas de reparation, il y a risque d'empoisonnement ou monoxyde de carbon ou de mort.

Ce compartiment doit être ferme sauf au moment de l'entretien.

PELIGRO

PELIGRO MONOXIDO DE CARBONO

TOXICO

El fracaso de no mantener compartimiento cerrado menos durante, atender, podria tener como resultado envenar de monoxido de carbona o muerte.

Este compartimiento debe cerrado menos al atender.

GENERAL INFORMATION

WARNING

TO PREVENT PROPERTY DAMAGE, PERSONAL INJURY OR DEATH DUE TO FIRE, EXPLOSIONS, SMOKE, SOOT, CONDENSATION, ELECTRIC SHOCK OR CARBON MONOXIDE, THIS UNIT MUST BE PROPERLY INSTALLED, REPAIRED, OPERATED AND MAINTAINED.

This unit is approved for outdoor installation ONLY. To assure that your unit operates safely and efficiently, it must be installed, operated, and maintained in accordance with these installation and operating instructions, all local building codes and ordinances, or in their absence, with the latest edition of the National Fuel Gas Code NFPA54/ANSI Z223.1 and National Standard of Canada CAN/CSA B149 Installa- tion Codes.

The heating and cooling capacities of the unit should be greater than or equal to the design heating and cooling loads of the area to be conditioned. The loads should be calculated by an approved method or in accordance with ASHRAE Guide or Manual J - Load Calculations published by the Air Condi- tioning Contractors of America.

Obtain from:

American National Standards Institute

1430 Broadway

New York, NY 10018

3

Image 3
Contents CPG Series Safety Instructions Replacement PartsGeneral Information High VoltageUnit Location Electrical Entrance Locations Before installing this unitUnit Clearances ClearancesRigging Details Roof Curb POST-INSTALLATION ChecksRoof Curb Installation Roof TOP Duct ConnectionsCorner & Center of Gravity Locations Electrical WiringDrop Power and LOW Voltage Block LocationsCPG240 GAS Heat GAS Supply PipingProper Piping Practice Natural Gas ConnectionTypical Propane GAS Piping Propane GAS InstallationsCirculating AIR and Filters Venting Condensate Drain ConnectionDrain Connection Moving Machinery Hazard STARTUP, ADJUSTMENTS, and ChecksRecommended Pounds of Force PER Belt Drive Belt Tension AdjustmentRollout Protection Control With Power And Gas On Burn Hazard Normal Sequence of Operation Heat Exchanger and Burner Orifice SpecificationsCheck rollout limit TroubleshootingInput Rating AIR Flow AdjustmentsMaintenance Motor Sheave AdjustmentsBurner Flame CPG180 Standard Belt Drive Appendix a Blower Performance Data Belt Drive High Static Appendix B Electrical Data Vertical Discharge TOP View Appendix C Unit DimensionsIIC 0140L00955 REV a IIC 0140L00957 REV a