Bryant HUM-56-1 manual Safety Considerations, Installation of HUMBBLBP2018-A Bypass Humidifier

Page 1

installation and

HUM

start-up instructions

 

HUMIDIFIERS AND

HUMIDISTAT

Cancels: II 912D-56-3

 

 

 

II HUM-56-1

 

7-98

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

MODEL HUMBBLFP1025-A--

FAN-POWERED

HUMIDIFIER

 

MODEL HUMBBSFP1016-A--

MODEL HUMBBLBP2018-A--

FAN-POWERED

HUMIDIFIER

BYPASS HUMIDIFIER

 

MODEL HUMBBWTR2019-A--

MODEL HUMBBSBP2017-A--

WATER-SAVER

 

BYPASS HUMIDIFIER

 

A98361

Humidifiers

NOTE: Read the entire instruction in manual applicable to specific unit before starting the installation. This symbol indicates a change since the last issue.

SAFETY CONSIDERATIONS

Improper installation, adjustment, alteration, service, maintenance, or use can cause explosion, fire, electrical shock, or other conditions which may cause personal injury or property damage. Consult a qualified installer, service agency, distributor, or branch for information or assistance. The qualified installer or agency must use factory-authorized kits or accessories when modifying this product. Refer to the individual instructions packaged with the kits or accessories when installing.

Follow all safety codes. Wear safety glasses and work gloves. Use quenching cloth for brazing operations. Have fire extinguisher available. Read these instructions thoroughly and follow all warnings or cautions attached to the unit. Consult local building codes and National Electrical Code (NEC) for special require- ments.

Recognize safety information. This is the safety-alert symbol . When you see this symbol on the unit and in instructions or manuals, be alert to the potential for personal injury.

Understand the signal words DANGER, WARNING, and CAU- TION. These words are used with the safety-alert symbol. DAN- GER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which would result in minor personal injury or product and property damage.

WARNING: Before installing or servicing system, al- ways turn off main power to system. There may be more than 1 disconnect switch. Turn off accessory heater power if applicable. Electrical shock can cause personal injury or death.

CAUTION: Unit must not be installed where freezing temperatures could occur. Do not install unit on the furnace or fan coil jacket. Do not install unit where ends of cooling coil could restrict airflow to the humidifier. Condensation damage could occur if home has closed- off, unheated rooms.

INSTALLATION OF HUMBBLBP2018-A--

BYPASS HUMIDIFIER

Bryant's HUMBBLBP2018-A-- bypass humidifier can be installed on either the supply or return plenum of a forced-air system. This unit requires an external bypass duct between the supply- and return-air ductwork.

It is recommended to install the humidifier where it can be easily serviced. If this humidifier is installed with a central cooling system the bypass duct must have a shutoff damper to close during the cooling season. Always install humidifier downstream of an electronic air cleaner.

Ð1Ð

Image 1
Contents Installation of HUMBBLBP2018-A Bypass Humidifier Safety ConsiderationsÐ1Ð → I. Inspect Package and Check Equipment → V. Install Bypass DuctII. Select Location see FIG III. Prepare Plenum Opening see FIGVIII. Install Humidistat and Complete Wiring VI. Install Drain LineInstallation of HUMBBLFP1025-A FAN Powered Humidifier VII. Make Water ConnectionVII. Install Humidistat and Complete Wiring → V. Install Drain LineVI. Make Water Connection VIII. START-UPÐ5Ð Installation of HUMBBSFP1016-A FAN Powered HumidifierIV. Mount the Humidifier Install Drain LineVI. Mount Solenoid Valve Ð6ÐIV. Mount Humidifier Installation of HUMBBSBP2017-A Bypass HumidifierÐ7Ð Ð8Ð Installation of HUMBBWTR2019-A Bypass Water Saver HumidifierÐ9Ð → ÐInstallation of HUMBBWTR2019-A-- Water Saver HumidifierWall Mounting LOW Voltage Installation of HumidistatIV. Adjustment III. WiringII. Duct Mounting LOW Voltage Operation Recommended Humidistat SettingVI. Checkout

HUM-56-1 specifications

The Bryant HUM-56-1 is a cutting-edge heating, ventilation, and air conditioning (HVAC) unit that has garnered attention in both residential and commercial sectors for its advanced features and efficient performance. Designed to provide optimal climate control, the HUM-56-1 incorporates several innovative technologies that set it apart from traditional HVAC systems.

One of the standout features of the Bryant HUM-56-1 is its high-efficiency design. The unit boasts an impressive Seasonal Energy Efficiency Ratio (SEER) rating, which indicates its ability to deliver maximum cooling with minimal energy consumption. This efficiency translates into lower utility bills and a reduced carbon footprint, making it an environmentally conscious choice for homeowners and businesses alike.

The HUM-56-1 employs advanced smart technology, including Wi-Fi connectivity and compatibility with smart home systems. This allows users to monitor and control their HVAC system remotely via mobile devices, providing convenience and flexibility. The unit also features programmable settings that enable users to customize their indoor climate according to their schedules, further enhancing energy savings and comfort.

Another key characteristic of the HUM-56-1 is its quiet operation. Equipped with sound-dampening features, the unit minimizes noise levels, ensuring a peaceful indoor environment. This is particularly beneficial for residential applications where noise disruption can impact daily life.

In terms of air quality management, the HUM-56-1 is designed to optimize indoor air quality. The unit is compatible with advanced filtration systems that remove allergens and pollutants from the air, making it an excellent choice for allergy sufferers. Additionally, the system’s ventilation capabilities ensure fresh air circulation, promoting a healthier living space.

Durability is a crucial aspect of the Bryant HUM-56-1. Constructed with high-quality materials, the unit is built to withstand various environmental conditions, ensuring longevity and reliable performance. Bryant also backs the HUM-56-1 with a comprehensive warranty, highlighting their commitment to quality and customer satisfaction.

Overall, the Bryant HUM-56-1 stands out in the HVAC market due to its efficiency, smart technology integration, quiet operation, enhanced air quality features, and durable construction. These characteristics make it a preferred choice for those seeking a reliable and effective climate control solution. Whether for residential or commercial use, the HUM-56-1 is poised to deliver outstanding performance and comfort all year round.