IV. MOUNT THE HUMIDIFIER

1.Attach foam tape to back of mounting flange (exclude the off-set edge).

2.Hook off-set edge over opening cut in plenum.

3.Place humidifier in plenum aligning screw holes with flange.

4.Align, level, and tighten all screws for air tight seal.

V.INSTALL DRAIN LINE

1.Use 5/8-in. vinyl tubing (field supplied) to connect drain on bottom of humidifier housing to an open drain.

2.Use clamp to hold drain tubing in position over drain fitting outlet.

CAUTION: Unit may leak if drain tubing is misapplied. Do not insert tubing inside of drain fitting outlet.

3.Make sure line is free of traps due to sagging and has sufficient pitch to drain.

VI. MOUNT SOLENOID VALVE

The water solenoid valve should be mounted on top of humidifier enclosure.

1.To mount solenoid on top, see Fig. 10.

a.Firmly press valve into the top inlet hole on enclosure. Seat valve flush against inlet hole.

2.If alternate mounting of solenoid is required, see Fig. 11.

a.To mount solenoid on side, use 3/8-in. ID, 1/2-in. OD vinyl tubing (field supplied). Place tubing onto valve stem and secure with clamp.

b.Mount valve upside down securing to side of housing.

c.Place open end of tubing into the top inlet hole.

IMPORTANT: Be careful not to kink tubing.

VII. MAKE WATER CONNECTION

If garden hose is not used for water supply:

1.Mount saddle valve on water line according to instructions supplied with valve.

2.Run 1/4-in. diameter (water line grade) tubing from saddle valve to adapter on solenoid valve and tighten compression fittings.

IMPORTANT: If water pressure is higher than normal (60 psi), use noise suppression disk included in parts bag. (Read water noise reducer note located inside package for instructions). For normal operation, saddle valve need only be opened 1 full turn to meet performance requirements.

TUBING

ENCLOSURE

INLET HOLE

POSITION TUBING INSIDE INLET HOLE (CUT LENGTH

IF REQUIRED)

A97099

Fig. 11ÐAlternate Mounting of Solenoid Valve

on HUMBBSFP1016-A-- Humidifier

3. Open valve and check installation for leaks.

NOTE: Saddle valve is self piercing on copper lines; 1/4-in. hole must be drilled in steel or iron pipes. Use only a grounded drill or a hand drill to avoid shock hazard. Turn off water and drain the pipe prior to drilling 1/4-in. hole.

VIII. INSTALL HUMIDISTAT AND COMPLETE WIRING

1.Mount humidistat on inside wall, or return-air duct in accordance with section INSTALLATION OF HUMIDIS- TAT on page 10.

2.Wire red and blue low-voltage leads. (See Fig. 6.)

3.Plug power cord in to 115-vac 60Hz source.

NOTE: Wiring must comply with National Electrical Code and any local codes or ordinances that may apply.

IX. START-UP

1.Open saddle valve to permit water flow to the solenoid.

2.Check all connections for water leaks.

3.Set thermostat to call for heat. Set humidistat for highest humidity setting making sure contacts are closed. After a few minutes of operation, check the drain connection for leaks and to see if water is flowing through humidifier.

4.Reverse thermostat and humidistat settings to insure proper shutdown.

5.Reset thermostat to normal setting. Reset humidistat to recommended setting.

X.FINAL STEPS

Attach humidifier maintenance instruction sticker to a visible location.

1.Inform homeowner of proper operation, maintenance, and humidistat setting.

a.If unit is installed during cooling season set humidistat for summer setting (OFF or lowest setting).

b.If installed during heating season, set unit for normal operation.

Ð6Ð

Image 6
Contents Safety Considerations Installation of HUMBBLBP2018-A Bypass HumidifierÐ1Ð II. Select Location see FIG → V. Install Bypass Duct→ I. Inspect Package and Check Equipment III. Prepare Plenum Opening see FIGInstallation of HUMBBLFP1025-A FAN Powered Humidifier VI. Install Drain LineVIII. Install Humidistat and Complete Wiring VII. Make Water ConnectionVI. Make Water Connection → V. Install Drain LineVII. Install Humidistat and Complete Wiring VIII. START-UPInstallation of HUMBBSFP1016-A FAN Powered Humidifier Ð5ÐVI. Mount Solenoid Valve Install Drain LineIV. Mount the Humidifier Ð6ÐInstallation of HUMBBSBP2017-A Bypass Humidifier IV. Mount HumidifierÐ7Ð Installation of HUMBBWTR2019-A Bypass Water Saver Humidifier Ð8Ð→ ÐInstallation of HUMBBWTR2019-A-- Water Saver Humidifier Ð9ÐInstallation of Humidistat Wall Mounting LOW VoltageIII. Wiring IV. AdjustmentII. Duct Mounting LOW Voltage Recommended Humidistat Setting OperationVI. Checkout

HUM-56-1 specifications

The Bryant HUM-56-1 is a cutting-edge heating, ventilation, and air conditioning (HVAC) unit that has garnered attention in both residential and commercial sectors for its advanced features and efficient performance. Designed to provide optimal climate control, the HUM-56-1 incorporates several innovative technologies that set it apart from traditional HVAC systems.

One of the standout features of the Bryant HUM-56-1 is its high-efficiency design. The unit boasts an impressive Seasonal Energy Efficiency Ratio (SEER) rating, which indicates its ability to deliver maximum cooling with minimal energy consumption. This efficiency translates into lower utility bills and a reduced carbon footprint, making it an environmentally conscious choice for homeowners and businesses alike.

The HUM-56-1 employs advanced smart technology, including Wi-Fi connectivity and compatibility with smart home systems. This allows users to monitor and control their HVAC system remotely via mobile devices, providing convenience and flexibility. The unit also features programmable settings that enable users to customize their indoor climate according to their schedules, further enhancing energy savings and comfort.

Another key characteristic of the HUM-56-1 is its quiet operation. Equipped with sound-dampening features, the unit minimizes noise levels, ensuring a peaceful indoor environment. This is particularly beneficial for residential applications where noise disruption can impact daily life.

In terms of air quality management, the HUM-56-1 is designed to optimize indoor air quality. The unit is compatible with advanced filtration systems that remove allergens and pollutants from the air, making it an excellent choice for allergy sufferers. Additionally, the system’s ventilation capabilities ensure fresh air circulation, promoting a healthier living space.

Durability is a crucial aspect of the Bryant HUM-56-1. Constructed with high-quality materials, the unit is built to withstand various environmental conditions, ensuring longevity and reliable performance. Bryant also backs the HUM-56-1 with a comprehensive warranty, highlighting their commitment to quality and customer satisfaction.

Overall, the Bryant HUM-56-1 stands out in the HVAC market due to its efficiency, smart technology integration, quiet operation, enhanced air quality features, and durable construction. These characteristics make it a preferred choice for those seeking a reliable and effective climate control solution. Whether for residential or commercial use, the HUM-56-1 is poised to deliver outstanding performance and comfort all year round.