Bryant HUM-56-1 manual → ÐInstallation of HUMBBWTR2019-A-- Water Saver Humidifier, Ð9Ð

Page 9

II.SELECT LOCATION (SEE FIG. 14.)

BYPASS UNITS

"N" COIL

DRILL (2) HOLES

IN DUCT

FOR #8 SHEETMETAL

SCREWS

VERTICALHORIZONTAL

A98369

Fig. 14ÐInstallation of HUMBBWTR2019-A-- Water Saver Humidifier

Humidifier may be installed on either supply or return plenum. If furnace has air conditioning coil, be sure humidifier does not interfere with coil ends. Remember to provide clearance for maintenance and evaporator pad removal.

III.PREPARE PLENUM OPENING (SEE FIG. 2.)

1.Use template for marking humidifier opening.

2.Tape in place on plenum making sure template is level.

IMPORTANT: For humidifier to operate properly it must be level and mounted on a vertical surface.

3.Drill four 1/8-in. holes in plenum.

4.Cut opening in plenum using heavy solid lines on template as a guide.

IV. MOUNT THE HUMIDIFIER

Supply or return plenum mounting:

1.Remove unit access door by turning 2 pawl latches 1/2 turn and pulling door forward.

2.Determine whether unit is to be used for right- or left-hand installation and apply gasket tape (supplied) to unit flange intended to seat against duct.

3.Remove media assembly from cabinet by lifting bearing end of assembly out of bearing retainer and pulling assem- bly toward outlet duct, thus disengaging media from motor. Remove media through unit access opening.

4.Remove pin from float assembly and remove float and arm. Remove drain plug and water pan.

NOTE: Water pan must be tilted for removal.

5.Mount unit to duct using pre-drilled holes and four 1/2-in. long screws found in parts bag.

6. Level unit and attach support bracket to unit using 1/4-in. blunt point screw. Attach other end of support bracket to duct by drilling a hole and using remaining 1/4-in. long screw.

7.Re-install water pan and drain plug. Re-attach float arm to valve body by aligning holes in both parts and re-inserting pin.

NOTE: Pin may be re-inserted from either direction.

8.Re-install media assembly. Ensure that square shaft of media assembly is located inside mating opening of motor coupling. Ensure that bearing washer is located on interior side of bearing retainer. (See Fig. 15.)

V. INSTALL BYPASS DUCT

Attach field-supplied 6-in. diameter duct, elbow, or starting collar with field-supplied 1/4-in. zip screws. Install supplied 6-in. damper in 6-in. duct connector.

IMPORTANT: On systems with central cooling, the damper should be closed during cooling season to prevent bypass air.

CAUTION: Do not support weight of duct from humidi- fier Ð damage could result.

VI. INSTALL DRAIN LINE

1.Use 1/2-in. ID field-supplied vinyl tubing or equivalent tubing to connect overflow drain connection on unit water pan to drain. (See Fig. 16.)

2.Use worm clamp to hold tubing in position over overflow drain connection.

IMPORTANT: Make sure that line is free of traps due to sagging and has sufficient pitch to drain.

3. Unit must be level to provide proper drainage.

14

OVERFLOW TUBE

DRAIN PLUG

A96013

Fig. 16ÐWater Level in HUMBBWTR2019-A--

VII. MAKE WATER CONNECTION

1.Mount saddle valve on cold water line according to local codes.

2.For plastic tube installations: run 1/4-in. OD tubing (sup- plied) from saddle valve to float valve. Prepare tubing ends with plastic compression sleeves and brass inserts, and tighten compression fittings. Plastic compression nut sup- plied with float valve should not be torqued greater than 25 in.-lb. For copper tubing installations: copper tubing may be connected to float valve by using a field-supplied 1/4 to 1/4 in. straight-through compression union. Run copper tubing to 1 side of compression union and use a standard compres- sion sleeve. Tighten compression nut to torque recom- mended by manufacturer. Attach approximately 6 in. of polyethylene supply tubing (supplied) between compres- sion union and float valve. Prepare polyethylene tubing on both ends with brass inserts to prevent tubing collapse. Use compression nut at union to manufacturer's recommended torque, tighten plastic nut on float valve to maximum of 25 in.-lb.

3.Open valve and check installation for leaks.

NOTE: Valve is self piercing on copper lines; 1/4-in. hole must be drilled in steel or iron pipes. Use only a grounded drill or a hand drill to avoid shock hazard. Turn off water and drain the pipe prior to drilling 1/4-in. hole.

Ð9Ð

Image 9
Contents Safety Considerations Installation of HUMBBLBP2018-A Bypass HumidifierÐ1Ð → I. Inspect Package and Check Equipment → V. Install Bypass DuctII. Select Location see FIG III. Prepare Plenum Opening see FIGVIII. Install Humidistat and Complete Wiring VI. Install Drain LineInstallation of HUMBBLFP1025-A FAN Powered Humidifier VII. Make Water ConnectionVII. Install Humidistat and Complete Wiring → V. Install Drain LineVI. Make Water Connection VIII. START-UPÐ5Ð Installation of HUMBBSFP1016-A FAN Powered HumidifierIV. Mount the Humidifier Install Drain LineVI. Mount Solenoid Valve Ð6ÐInstallation of HUMBBSBP2017-A Bypass Humidifier IV. Mount HumidifierÐ7Ð Ð8Ð Installation of HUMBBWTR2019-A Bypass Water Saver HumidifierÐ9Ð → ÐInstallation of HUMBBWTR2019-A-- Water Saver HumidifierWall Mounting LOW Voltage Installation of HumidistatIII. Wiring IV. AdjustmentII. Duct Mounting LOW Voltage Recommended Humidistat Setting OperationVI. Checkout

HUM-56-1 specifications

The Bryant HUM-56-1 is a cutting-edge heating, ventilation, and air conditioning (HVAC) unit that has garnered attention in both residential and commercial sectors for its advanced features and efficient performance. Designed to provide optimal climate control, the HUM-56-1 incorporates several innovative technologies that set it apart from traditional HVAC systems.

One of the standout features of the Bryant HUM-56-1 is its high-efficiency design. The unit boasts an impressive Seasonal Energy Efficiency Ratio (SEER) rating, which indicates its ability to deliver maximum cooling with minimal energy consumption. This efficiency translates into lower utility bills and a reduced carbon footprint, making it an environmentally conscious choice for homeowners and businesses alike.

The HUM-56-1 employs advanced smart technology, including Wi-Fi connectivity and compatibility with smart home systems. This allows users to monitor and control their HVAC system remotely via mobile devices, providing convenience and flexibility. The unit also features programmable settings that enable users to customize their indoor climate according to their schedules, further enhancing energy savings and comfort.

Another key characteristic of the HUM-56-1 is its quiet operation. Equipped with sound-dampening features, the unit minimizes noise levels, ensuring a peaceful indoor environment. This is particularly beneficial for residential applications where noise disruption can impact daily life.

In terms of air quality management, the HUM-56-1 is designed to optimize indoor air quality. The unit is compatible with advanced filtration systems that remove allergens and pollutants from the air, making it an excellent choice for allergy sufferers. Additionally, the system’s ventilation capabilities ensure fresh air circulation, promoting a healthier living space.

Durability is a crucial aspect of the Bryant HUM-56-1. Constructed with high-quality materials, the unit is built to withstand various environmental conditions, ensuring longevity and reliable performance. Bryant also backs the HUM-56-1 with a comprehensive warranty, highlighting their commitment to quality and customer satisfaction.

Overall, the Bryant HUM-56-1 stands out in the HVAC market due to its efficiency, smart technology integration, quiet operation, enhanced air quality features, and durable construction. These characteristics make it a preferred choice for those seeking a reliable and effective climate control solution. Whether for residential or commercial use, the HUM-56-1 is poised to deliver outstanding performance and comfort all year round.