PureAV Power Console
Operation
Central LCD Control Panel
The PureAV Power Console is equipped with an advanced LCD Control Panel. Most functions of the Power Console can be monitored from this display.
A. PureFilter Indicator – shows that the multiphase PureFilter Circuitry is functioning properly.
B. Volt Meter – displays the input voltage (the amount of voltage coming from the AC wall socket to the Power Console).
C.Current Meter – displays the output current (the amount of current output [in Amps] from the Power Console’s socket banks). You can choose to see the current output from all of the banks at the same time or individual banks using the “Bank Selector” button.
D.Socket Banks – display the currently selected bank(s) for monitoring output current (controlled with the “Bank” button).
E.Wiring – indicates whether the AC socket to which the Power Console is connected is wired properly, or
– Wiring OK.
– Live and neutral wires are reversed. See page 23 in the “Troubleshooting” section for more information.
F.Earthed – indicates if the Power Console is connected to a properly earthed AC socket.
– Earth OK. The AC wall socket is properly earthed.
– Earth Fault. This indicates that the AC wall socket is NOT properly earthed. See page 22 in the “Troubleshooting” section for more information.
G.Switched Indicator – shows whether the “Switched” sockets are switched ON or OFF.
H.Timed Delay Indicator – shows that the delayed sockets are switched ON after a delay.
I.Remote Indicator – shows whether the remote function is ON or OFF (controlled with the “Remote” button).
J.Remote Button – switches the Power Console to “Remote ON” status when pressed. When in “Remote ON” status, the Power Console sockets programmed as switched are turned ON/OFF via external remote signal (see page 10).
19