BRK electronic SC6120B user manual Using the Silence Feature, When the Smoke Alarm is Silenced

Page 18

USING THE SILENCE FEATURE

The Silence Feature is intended to temporarily silence the horn while you identify and correct the problem. Do not use the Silence Feature in emergency situations. It will not correct a CO problem or extinguish a fire.

To use the Silence Feature, briefly press the Test/Silence button on the cover of the Smoke/CO Alarm.

To silence Alarms in an interconnected series:

To silence all the Alarms in an interconnected series, you must press the Test/Silence button on the unit(s) that triggered the alarm.

NOTE: The red light on the initiating Alarms will flash rapidly. The red light will be off on all other Alarms.

Never interrupt AC power or remove the battery to quiet an unwanted alarm. Disabling the Alarm removes your protection.

WHEN THE SMOKE ALARM IS SILENCED...

The Smoke Alarm will remain silent for up to 15 minutes and then return to normal operation. If the smoke has not cleared within the silence period or if smoke increases to a critical level during the silence period, the unit will go back into alarm.

Use the Silence Feature only if you are certain of the source of smoke. If you are not certain of the source or a fire starts while you are clearing smoke, evacuate the house immediately.

WHEN THE CO ALARM IS SILENCED...

The CO Alarm will remain silent for 4 minutes. After 4 minutes, if CO levels remain potentially dangerous the horn will start sounding again.

The Silence Feature is intended to temporarily silence the Alarm horn. It will not correct a CO problem.

LOW BATTERY SILENCE FEATURE

If AC power is on, briefly press the Test/Silence button to silence the low battery “chirp” for up to 8 hours. The Alarm will continue to operate as long as AC power is supplied. However, replace the battery as soon as possible, to maintain protection in event of a power outage.

16

Image 18
Contents Smoke Alarm Basic FeaturesCO Alarm Model SC6120B-USER’S ManualTable of Contents IntroductionBasic safety information Alarm Specifications Carbon Monoxide AlarmSpecifications HOW Your SMOKE/CO Alarm Works Cover of Your SMOKE/CO Alarm Installation Where to Install this AlarmRecommended Placement Installing Smoke/CO Alarms in Mobile Homes KEYWhere not to Install this Alarm Do not locate this Smoke/CO AlarmAvoiding Dead AIR Spaces Important Installation Parts Locking FeaturesTo Lock the Battery Compartment To Unlock the Battery CompartmentUnlock the Battery Compartment To Lock the Mounting BracketTo Unlock the Mounting Bracket Tuck the White/Gray Stripe wire inside HOW to Install this AlarmTo install this unit, follow these steps Parts Of This UnitInterconnecting Multiple Alarms Installing a Single Stand-Alone AlarmInterconnecting Multiple Alarms Smoke Alarms Activate the Battery BACK-UP If the CO Alarm Sounds If Your SMOKE/CO Alarm SoundsWhat to do FIRST-IDENTIFY the Type of Alarm What to do if Carbon Monoxide is DetectedResponding to AN Alarm What to do if Smoke is DetectedWhen the CO Alarm is Silenced Using the Silence FeatureWhen the Smoke Alarm is Silenced LOW Battery Silence FeatureLatching Alarm Indicator KEYTesting and Maintenance Weekly TestingIf the Smoke/CO Alarm does not test properly Regular Maintenance Choosing a Replacement BatteryProtecting Your Family From CO PoisoningFollow safety rules, and prevent hazardous situations From FireProtecting Your Family Finding the Source CO After AN Alarm What is CO?Symptoms of CO Poisoning What YOU Need to Know about CORegulatory Information for CO Alarms What Levels of CO Cause AN ALARM?UL2034 Required Alarm Points Nfpa 72 National Fire Code Regulatory Information for Smoke AlarmsAgency Placement Recommendations California State Fire Marshall CsfmHotels/Motels Special Compliance ConsiderationsInstitutions Warehouses/Commercial BuildingsDifferent Types of Smoke Alarms Troubleshooting Guide Understanding the Light and Horn Patterns Condition LED Red or Green Lights HornGeneral Limitations of this Alarm Limited Warranty How to Obtain Warranty Service

SC6120B specifications

The BRK electronic SC6120B is a state-of-the-art combination smoke and carbon monoxide (CO) detector designed to provide optimal protection for homes and workplaces. This innovative device is engineered to enhance safety by detecting both smoke from fires and the presence of carbon monoxide, which is often referred to as the "silent killer" due to its odorless and colorless nature.

One of the standout features of the SC6120B is its Voice Alarm system, which emits distinct voice alerts to inform users whether smoke or CO is detected. This audio notification is crucial in emergency situations, as it allows individuals to respond quickly and appropriately. The device also includes a loud, 85-decibel alarm that further enhances alertness in the event of a danger.

The SC6120B utilizes advanced sensing technology to improve detection accuracy. It is equipped with a photoelectric smoke sensor that is known for its rapid response to smoldering fires, which produce smoke without a significant flame. This type of sensor is particularly effective for detecting slow-burning fires, such as those that begin with electrical equipment or household materials. Additionally, the SC6120B has an electrochemical sensor for CO detection, ensuring that it can identify elevated levels of carbon monoxide swiftly.

This unit is also designed for user convenience and reliability. It features a one-button test/hush function that allows users to easily test the unit's functionality or silence false alarms caused by cooking smoke or steam. The SC6120B has a low battery indicator that alerts users when it's time to replace the batteries, ensuring that the device remains operational at all times.

Another remarkable characteristic of the SC6120B is its compact and modern design, making it suitable for various environments, including bedrooms, hallways, and living rooms. It is easy to install, with a battery-operated option that eliminates the need for hardwiring, thus providing flexibility in placement.

In summary, the BRK electronic SC6120B combines innovative features, user-friendly technology, and effective safety detection into one reliable unit. Its dual function of smoke and CO detection, along with its loud alarms and voice notifications, make it an essential device for safeguarding life and property from the dangers of fire and carbon monoxide.