BRK electronic SC6120B user manual Alarm Specifications, Carbon Monoxide Alarm

Page 4

Basic safety information (continued)...

Test this Smoke/CO Alarm once a week. If it ever fails to test correctly, have it replaced immediately! If the Alarm is not working properly, it cannot alert you to a problem.

Do not paint over the Smoke/CO Alarm. Paint may clog the openings to the sensing chamber and prevent the sensors from operating properly.

DO NOT spray cleaning chemicals or insect sprays directly on or near the Smoke/CO Alarm. Doing so may permanently damage the Alarm. DO NOT expose the Alarm to strong fumes. For example, painting or fumigating.

ALARM SPECIFICATIONS

Audible Alarm: 85dB minimum at 10 feet (3 meters)

Power: Powered by 120VAC. The 9V battery back-up provides 8 hours of standby and sounds alarm for 12 hours with fresh battery. When AC power is on, green light (LED) shines continuously. Under battery power, green light flashes once a minute.

Malfunction: Horn chirps and green light blinks 3 times (in rapid succession) every minute.

Supply Voltage: 120VAC 60Hz, 0.09A

Warranty: 5-year limited warranty.

Continued...

Specifications (continued)...

THE SMOKE ALARM

During Alarm: Repeating Horn Pattern: 3 beeps, pause, 3 beeps, pause, until silence button is pressed, smoke dissipates, or power is lost.

Stand-alone unit: Red Smoke light (LED) flashes once per second.

Interconnected series: Red Smoke light (LED) flashes once per second on the initiating Alarm. Red lights (LED) on all other alarms will not flash.

Standards: Underwriters Laboratories Inc. Single and Multiple Station Smoke Alarms 217.

THE CARBON MONOXIDE ALARM

Gas Detection at Typical Temperature and Humidity Ranges: The CO Alarm is not formulated to detect CO levels below 30 ppm typically. UL tested for false alarm resistance to Methane (500 ppm), Butane (300 ppm), Heptane (500 ppm), Ethyl Acetate (200 ppm), Isopropyl Alcohol (200 ppm) and Carbon Dioxide (5000 ppm). Values measure gas and vapor concentrations in parts per million.

Required Alarm Levels: Before 10% COHb exposure at levels of 30% to 70% Relative Humidity (RH). 400 ppm CO between 4 and 15 minutes;150 ppm CO between 10 and 50 minutes; 70 ppm CO between 60 and 240 min- utes. The unit is designed not to alarm when exposed to a constant level of 30 ppm for 30 days.

During Alarm: Repeating Horn Pattern: 4 beeps, pause, 4 beeps, pause, until CO level falls below

70 ppm, silence button is pressed, or power is lost.

Stand-alone unit: Red CO light (LED) flashes once per second.

Interconnected series: Red CO light (LED) flash- es once per second on the initiating Alarm. Red lights (LED) on all other Alarms will not flash.

2

Continued...

Image 4
Contents Basic Features CO AlarmSmoke Alarm Model SC6120B-USER’S ManualTable of Contents IntroductionBasic safety information Carbon Monoxide Alarm Alarm SpecificationsSpecifications HOW Your SMOKE/CO Alarm Works Cover of Your SMOKE/CO Alarm Where to Install this Alarm InstallationRecommended Placement Installing Smoke/CO Alarms in Mobile Homes KEYDo not locate this Smoke/CO Alarm Where not to Install this AlarmAvoiding Dead AIR Spaces Important Installation Parts Locking FeaturesTo Lock the Battery Compartment To Unlock the Battery CompartmentTo Lock the Mounting Bracket Unlock the Battery CompartmentTo Unlock the Mounting Bracket HOW to Install this Alarm To install this unit, follow these stepsTuck the White/Gray Stripe wire inside Parts Of This UnitInstalling a Single Stand-Alone Alarm Interconnecting Multiple AlarmsInterconnecting Multiple Alarms Smoke Alarms Activate the Battery BACK-UP If Your SMOKE/CO Alarm Sounds What to do FIRST-IDENTIFY the Type of AlarmIf the CO Alarm Sounds What to do if Carbon Monoxide is DetectedResponding to AN Alarm What to do if Smoke is DetectedUsing the Silence Feature When the Smoke Alarm is SilencedWhen the CO Alarm is Silenced LOW Battery Silence FeatureLatching Alarm Indicator KEYWeekly Testing Testing and MaintenanceIf the Smoke/CO Alarm does not test properly Regular Maintenance Choosing a Replacement BatteryProtecting Your Family From CO PoisoningFrom Fire Follow safety rules, and prevent hazardous situationsProtecting Your Family What is CO? Symptoms of CO PoisoningFinding the Source CO After AN Alarm What YOU Need to Know about COWhat Levels of CO Cause AN ALARM? Regulatory Information for CO AlarmsUL2034 Required Alarm Points Regulatory Information for Smoke Alarms Agency Placement RecommendationsNfpa 72 National Fire Code California State Fire Marshall CsfmSpecial Compliance Considerations InstitutionsHotels/Motels Warehouses/Commercial BuildingsDifferent Types of Smoke Alarms Troubleshooting Guide Understanding the Light and Horn Patterns Condition LED Red or Green Lights HornGeneral Limitations of this Alarm Limited Warranty How to Obtain Warranty Service

SC6120B specifications

The BRK electronic SC6120B is a state-of-the-art combination smoke and carbon monoxide (CO) detector designed to provide optimal protection for homes and workplaces. This innovative device is engineered to enhance safety by detecting both smoke from fires and the presence of carbon monoxide, which is often referred to as the "silent killer" due to its odorless and colorless nature.

One of the standout features of the SC6120B is its Voice Alarm system, which emits distinct voice alerts to inform users whether smoke or CO is detected. This audio notification is crucial in emergency situations, as it allows individuals to respond quickly and appropriately. The device also includes a loud, 85-decibel alarm that further enhances alertness in the event of a danger.

The SC6120B utilizes advanced sensing technology to improve detection accuracy. It is equipped with a photoelectric smoke sensor that is known for its rapid response to smoldering fires, which produce smoke without a significant flame. This type of sensor is particularly effective for detecting slow-burning fires, such as those that begin with electrical equipment or household materials. Additionally, the SC6120B has an electrochemical sensor for CO detection, ensuring that it can identify elevated levels of carbon monoxide swiftly.

This unit is also designed for user convenience and reliability. It features a one-button test/hush function that allows users to easily test the unit's functionality or silence false alarms caused by cooking smoke or steam. The SC6120B has a low battery indicator that alerts users when it's time to replace the batteries, ensuring that the device remains operational at all times.

Another remarkable characteristic of the SC6120B is its compact and modern design, making it suitable for various environments, including bedrooms, hallways, and living rooms. It is easy to install, with a battery-operated option that eliminates the need for hardwiring, thus providing flexibility in placement.

In summary, the BRK electronic SC6120B combines innovative features, user-friendly technology, and effective safety detection into one reliable unit. Its dual function of smoke and CO detection, along with its loud alarms and voice notifications, make it an essential device for safeguarding life and property from the dangers of fire and carbon monoxide.