BRK electronic SC6120B user manual Table of Contents, Introduction

Page 2

TABLE OF CONTENTS

Chapter 1: Introduction . . . . . . . . . . .Inside Cover

Basic Features . . . . . . . . . . . . . . . . .Front Cover

Basic Safety Information . . . . . . . . .Inside Cover

Smoke/CO Alarm Specifications . . . . . . . . . . . .2

How Your Smoke/CO Alarm Works . . . . . . . . . .3

Chapter 2: Installation . . . . . . . . . . . . . . . . . . . . . .4

Where to Install This Alarm . . . . . . . . . . . . . . . .4 Where NOT To Install This Alarm . . . . . . . . . . . .6 Locking Features . . . . . . . . . . . . . . . . . . . . . . . .7 How to Install This Alarm . . . . . . . . . . . . . . . . .10

Chapter 3: If Your Smoke/CO Alarm Sounds . . .14

What To Do If Carbon Monoxide is Detected . .14 What To Do If Smoke Is Detected . . . . . . . . . .15 Using the Silence Feature . . . . . . . . . . . . . . . .16 The ‘Latching Alarm’ Indicator . . . . . . . . . . . . .17

Chapter 4: Testing and Maintenance . . . . . . . . .18

Chapter 5: Protecting Your Family . . . . . . . . . . .20

Protecting Your Family From CO Poisoning . . .20 Protecting Your Family From Fire . . . . . . . . . . .21

Chapter 6: What You Need To Know About CO .22

Chapter 7: Regulatory Information

for CO Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . .23

Chapter 8: Regulatory Information

for Smoke Alarms . . . . . . . . . . . . . . . . . . . . . . . .24 Chapter 9: Troubleshooting Guide . . . . . . . . . . .27

Chapter 10: Understanding the Light

and Horn Patterns . . . . . . . . . . . . . . . . . . . . . . . .28

Chapter 11: General Limitations

Of CO/Smoke Alarms . . . . . . . . . . . . . . . . . . . . .29 Limited Warranty . . . . . . . . . . . . . . . . . . . . . . . . .30

CHAPTER 1: INTRODUCTION

BASIC SAFETY INFORMATION

Dangers, Warnings, and Cautions alert you to impor- tant operating instructions or to potentially hazardous situations. Pay special attention to these items.

This combination Smoke and Carbon Monoxide Alarm will only indicate the presence of smoke or CO at the sensor. Carbon Monoxide gas or smoke may be present in other areas. The unit is not designed to sense other gases, heat or flames.

This Smoke/CO Alarm is approved for use in single-fami- ly residences. It is NOT designed for marine or RV use.

This device is not intended to alert hearing impaired residents. Smoke alarms specifically designed for the hearing impaired, which feature devices like flashing strobe lights, are available to alert the hearing impaired in case of fire.

ELECTRICAL SHOCK HAZARD. Turn off power to the area where you will install this unit at the circuit breaker or fuse box before beginning installation. Failure to turn off the power before installation may result in serious electrical shock, injury or death.

Image 2
Contents Smoke Alarm Basic FeaturesCO Alarm Model SC6120B-USER’S ManualTable of Contents IntroductionBasic safety information Specifications Alarm SpecificationsCarbon Monoxide Alarm HOW Your SMOKE/CO Alarm Works Cover of Your SMOKE/CO Alarm Recommended Placement InstallationWhere to Install this Alarm Installing Smoke/CO Alarms in Mobile Homes KEYAvoiding Dead AIR Spaces Where not to Install this AlarmDo not locate this Smoke/CO Alarm Important Installation Parts Locking FeaturesTo Lock the Battery Compartment To Unlock the Battery CompartmentTo Unlock the Mounting Bracket Unlock the Battery CompartmentTo Lock the Mounting Bracket Tuck the White/Gray Stripe wire inside HOW to Install this AlarmTo install this unit, follow these steps Parts Of This UnitInterconnecting Multiple Alarms Interconnecting Multiple AlarmsInstalling a Single Stand-Alone Alarm Smoke Alarms Activate the Battery BACK-UP If the CO Alarm Sounds If Your SMOKE/CO Alarm SoundsWhat to do FIRST-IDENTIFY the Type of Alarm What to do if Carbon Monoxide is DetectedResponding to AN Alarm What to do if Smoke is DetectedWhen the CO Alarm is Silenced Using the Silence FeatureWhen the Smoke Alarm is Silenced LOW Battery Silence FeatureLatching Alarm Indicator KEYIf the Smoke/CO Alarm does not test properly Testing and MaintenanceWeekly Testing Regular Maintenance Choosing a Replacement BatteryProtecting Your Family From CO PoisoningProtecting Your Family Follow safety rules, and prevent hazardous situationsFrom Fire Finding the Source CO After AN Alarm What is CO?Symptoms of CO Poisoning What YOU Need to Know about COUL2034 Required Alarm Points Regulatory Information for CO AlarmsWhat Levels of CO Cause AN ALARM? Nfpa 72 National Fire Code Regulatory Information for Smoke AlarmsAgency Placement Recommendations California State Fire Marshall CsfmHotels/Motels Special Compliance ConsiderationsInstitutions Warehouses/Commercial BuildingsDifferent Types of Smoke Alarms Troubleshooting Guide Understanding the Light and Horn Patterns Condition LED Red or Green Lights HornGeneral Limitations of this Alarm Limited Warranty How to Obtain Warranty Service

SC6120B specifications

The BRK electronic SC6120B is a state-of-the-art combination smoke and carbon monoxide (CO) detector designed to provide optimal protection for homes and workplaces. This innovative device is engineered to enhance safety by detecting both smoke from fires and the presence of carbon monoxide, which is often referred to as the "silent killer" due to its odorless and colorless nature.

One of the standout features of the SC6120B is its Voice Alarm system, which emits distinct voice alerts to inform users whether smoke or CO is detected. This audio notification is crucial in emergency situations, as it allows individuals to respond quickly and appropriately. The device also includes a loud, 85-decibel alarm that further enhances alertness in the event of a danger.

The SC6120B utilizes advanced sensing technology to improve detection accuracy. It is equipped with a photoelectric smoke sensor that is known for its rapid response to smoldering fires, which produce smoke without a significant flame. This type of sensor is particularly effective for detecting slow-burning fires, such as those that begin with electrical equipment or household materials. Additionally, the SC6120B has an electrochemical sensor for CO detection, ensuring that it can identify elevated levels of carbon monoxide swiftly.

This unit is also designed for user convenience and reliability. It features a one-button test/hush function that allows users to easily test the unit's functionality or silence false alarms caused by cooking smoke or steam. The SC6120B has a low battery indicator that alerts users when it's time to replace the batteries, ensuring that the device remains operational at all times.

Another remarkable characteristic of the SC6120B is its compact and modern design, making it suitable for various environments, including bedrooms, hallways, and living rooms. It is easy to install, with a battery-operated option that eliminates the need for hardwiring, thus providing flexibility in placement.

In summary, the BRK electronic SC6120B combines innovative features, user-friendly technology, and effective safety detection into one reliable unit. Its dual function of smoke and CO detection, along with its loud alarms and voice notifications, make it an essential device for safeguarding life and property from the dangers of fire and carbon monoxide.