| 12. TECHNICAL SPECIFICATIONS |
|
| |
Operating Voltage | : 230±10% VAC, 50Hz | |
Power | : | 1 Watt (60 mA) |
Power on Indicator | : | Green Light |
Sensor | : | Electrochemical Sensor |
CO Sensitivity | : Meets BS EN 50291: 2001. | |
|
| Unit operates as per Table B (on page 8). |
Electrical Safety | : Complies with relevant sections of EN | |
Electromagnetic | : Complies with BS EN 50270 | |
Compatibility |
|
|
Test/Hush Button | : Checks electronics and horn. | |
|
| When the unit is alarming, after sensing CO, pressing the Test/Hush button will immediately stop |
|
| the horn (the red light will continue to flash). If CO is still present the red light and the horn will turn |
|
| on again after about 4 minutes. The unit can only be silenced once during a CO incident. At 300 |
|
| ppm CO the unit cannot be silenced. (With interconnected units, the Hush only works on the alarm |
|
| sensing CO). |
Fast CO Test Mode | : Pressing the Test/Hush button also causes the unit to check for CO 4 | |
|
| seconds later to facilitate testing in CO gas. It gives 3 beeps and the red light |
|
| flashes to indicate the CO level if CO is sensed and then resets. |