Ei Electronics Ei261DENRC, Ei261ENRC manual Important Information

Page 4

B16132-R0-261ENRC-UC-ENG 7/11/07 11:52 AM Page 4

1. IMPORTANT INFORMATION

WARNING: The Alarm should be permanently wired to the mains by a qualified electrician in accordance with IEE wiring regulations (BS7671).

Install a Carbon Monoxide (CO) Alarm in every room that contains a fuel burning appliance, particularly rooms where people spend a lot of time e.g. bedrooms, kitchens and sitting rooms.

In rooms with an appliance, install (preferably) on the ceiling (300mm from walls and between 1m to 3m horizontally from appliance). In rooms remote from the appliance install at breathing level, where the light indicators can be seen.

Regularly check that the green power light is on, so that rechargeable back-up cells will remain fully charged. Important: The CO Alarm will not work if the mains supply is off and the rechargeable cells are depleted.

Test the unit weekly by pressing and holding the Test/Hush button. The horn will sound.

Replace sensor module after 5 years operation (see page 23).

4

Image 4
Contents Mains Powered Carbon Monoxide Alarms B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Contents Important Information What to do When the Alarm Sounds What is Carbon Monoxide ? Symptoms of Carbon Monoxide PoisoningCarbon Monoxide the Silent Killer High levels of CO in a house can be caused byInhalation Time approx and Symptoms Developed Table a Effects of Carbon Monoxide PoisoningWhat Happens When Your CO Alarm Detects Carbon Monoxide ? Never Ignore the Alarm CO Alarm MemoryIdeally a Carbon Monoxide CO Alarm should be Installed Alarm PositioningUnsuitable Locations B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Location in room with a fuel burning appliance Location in rooms with Installation Alarm InstallationInstallation Procedure B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Surface Wiring Interconnecting Testing Testing with Carbon Monoxide Maintenance HOW to Distinguish Between CO Alarm & Smoke Alarm WarningsDo not paint the CO Alarm HOW to Disconnect and Remove the Alarm Sensor Module ReplacementLimitations of CO Alarms HOW to Protect Your Family B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Getting Your CO Alarm Serviced Five Year GuaranteeTechnical Specifications B16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Alarm does not Work When the Test Button is Pressed TroubleshootingAlarm Beeps and Amber Light Flashes Every 40 Seconds Alarm Sounds for no Apparent Reason Test/Hush Button does not Silence AlarmsAccessories CheckB16132-R0-261ENRC-UC-ENG 7/11/07 1152 AM Ei Electronics