Note: Ceiling mounting is recommended - do not wall mount alarms.

Sloping Ceiling

In areas with sloping or peaked ceilings install the alarm 900mm from the highest point measured horizontally (see Figure 2). This is because “dead air” at the apex may prevent smoke from reaching the unit.

4.1 Locations To Avoid

DON’T place Multi-Sensor Fire Alarms in any of the following areas:

Bathrooms, kitchens, shower rooms, garages or other rooms where the alarm may be triggered by steam, condensation, normal smoke or fumes. Keep at least 6 metres away from sources of normal smoke/fumes.

DON’T place Heat Alarms in any of the following areas:

Bathrooms, shower rooms or other rooms where the unit may be triggered by steam or condensation.

DON’T place Multi-Sensor Fire Alarms in any of the following areas:

Places where the normal temperature can exceed 40°C or be below 4°C (e.g. attics, furnace rooms, directly above ovens or kettles etc.) as the heat/steam could cause nuisance alarms.

Near a decorative object, door, light fitting, window moulding etc., that may prevent smoke or heat from entering the unit.

Surfaces that are normally warmer or colder than the rest of the room (e.g. attic hatches). Temperature differences might stop smoke or heat from reaching the unit.

16

Image 16
Contents Installer Instructions Contents Interconnect ALL Alarms Installation Guide Alarm Removal Faster Response to a wider range of fires Reduced Nuisance AlarmsIncreased Longevity and Ruggedness Alarm Memory Replace Alarm IndicatorSingle Person Interconnect Test Fire Risk Assessment Categories of System LD3 Minimum Protection LD2 Additional Protection LD1 Optimum Protection Selecting Alarm Type Alarm TypeGrade D, E & F Systems Improved AudibilityPositioning Alarms DON’T place Heat Alarms in any of the following areas Locations To AvoidInstallation B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 346 PM Mounting & Wiring Alarms B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 346 PM Removeable Trunking Door for B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 346 PM Interconnecting Alarms B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 346 PM Remote Control Switch Ei1529RC Relay Module Ei128RRadioLINK Base Ei168RC B16350-R0-Ei2100 SERIES-U&C.qxd 18/9/08 346 PM B16350 Rev0 Ei Electronics