Walk Test

￿I have this feature.

￿I do not have this feature.

￿This feature requires a passcode.

Use this function to test keypads, detection devices, and sounders (both interior and exterior) to be certain they function properly. You can review untested points at your keypad to help pinpoint any problems.

You cannot arm your system while in the Walk Test Mode, and no Alarm Reports are sent to your security company unless a 24-hour point is activated (such as fire or panic).

Note:

The AC is disabled for 4 minutes to test the system’s battery power. If the

 

battery cannot maintain the system for the 4 minutes period, the keypad

 

beomes unresponisive. If this happens, contact your security company. At

 

the end of the 4 minutes period, AC is returns to the system and the control

 

panel restores.

To test individual detection devices, simply activate sensors and open protected doors and windows one at a time. As each detection device is faulted, the keypad emits a brief tone and the display indicates the point is tested. This verifies that each detection device is working properly.

COMMAND 4 4

To use Walk Test:

1.Ensure your security system is idle.

2.Press the [COMMAND] bar. The Command mode indicator light comes on.

3.Press the [4] key, and then the [4] key again. Audible devices (both interior and exterior) sound the burglary bell.

4.After silencing the audible devices, you can test detection devices. Open a door or window or activate a motion sensor. Each time a detection device is tested, the keypad beeps for 2 seconds. The keypad display panel indicates the point you faulted verifying that the detection device is working properly.

5.To end the Walk Test, press any numeric key on the keypad. If no activity occurs on the system for 20 minutes, the Walk Test ends automatically.

17

Image 17
Contents LED Keypads D720 Series User’s Guide Table of Contents Case of Fire Fire SafetyAC Power Failure Maintenance and ServiceIntroduction D720 Series KeypadSecurity System Basics Keypad FeaturesKeypad Function Keys Turning the System On ArmingTurning the System Off Disarming Reporting to the Central Station Silencing an AlarmTo Silence an alarm Keypad Tones Silenced until the point fault is correctedCommand Turn the Entire System On With DelaysArming with Command ApplicationUsing Command Turn the Entire System On Without DelaysCommand 1 Turn On the Perimeter With No Delays Turn On the Perimeter With Delays Silence the Trouble Sounder To use CommandSend Report Command 4 1 & 4To use Command 4 1 or Command 4 To use Command 4 Enable Remote Account ManagementCommand 4 To use Walk Test Walk TestTo reset detectors Reset SensorsTo delete passcodes Command 5Delete Passcodes To change your personal passcode Personal Passcode ChangeTo use Fire Test Fire TestWatch Mode Special Alert To engage CommandPartially Turn On the Perimeter To arm with CommandCommand To use Bypass a Point Bypass a PointTo Unbypass a Point Command 0Unbypass a Point Passcode + 1, or + Turning the System On With a Duress PasscodeForce Arming the System To arm with points faultedSecurity System Glossary Security System Limitations