2 FPA‑1000 Analog Addressable Fire Panels
interface. Therefore, no software installation is required. The panel can receive diagnostics from a Web browser running on a networked PC.
System Overview
Functions
Peer-to-peer Communications
The FPA‑1000 panels
Networked panels act as a single panel – enabling all events to be displayed on all units. All connected panels can easily be programmed and controlled via any connected panel.
Ethernet, fiber optic, or
System Management
A set of interactive Web pages gives you an instant means to access and record important system functions. This unique feature enables programming and diagnostic capabilities while offsite, streamlining installation and reducing the time required for servicing the system. And, you can check status and manage the system from virtually anywhere on the network.
Communications
The FPA‑1000 panel has a dual phone line PSTN/DACT circuit and an Ethernet connection featuring Conettix IP reporting. The panel communicates in Contact ID, SIA, and Modem IIIa2. The panel provides miscellaneous reporting functions such as dialing
control and transmission supervision, priorities of report groups, routing to destinations, manual and auto test reports, and
For the primary and secondary account, the following features are programmable:
•Two different phone or IP numbers
•Different dialing types for PSTN (pulse only, automatic, or tone only)
•Individual PSTN line supervision (audible and visual trouble signal in the case of a transmission path failure)
•Selectable options for Report Steering Groups
•Programmable acknowledge wait time for each IP reporting Conettix account (10 sec up to 255 sec)
•Test report frequency individually programmable for each account (4, 12, 24 hour, 7 and 28 day intervals, standard frequency 24 hour)
Applications
The
•Retail – single building applications
•Education – schools and universities
•Residential - apartment buildings
•Commercial – manufacturing plants, warehouses and office complexes
•Government and Public Service – military bases and installations
•Medical – healthcare facilities
Multi-criteria Detectors
A range of pull stations, modules, accessories and detectors are available to meet the needs of your application. These include the new Automatic Fire Detector 440 Series that incorporate
Gas detection
Integrated gas detection is an important element of your facility’s fire and life safety strategy. Using
Notification Appliance Circuits (NACs)
Two Class A Style Z or Class B Style Y NACs provide up to 4 A of 24 V power