7 FPA‑1000 Analog Addressable Fire Panels
FLM‑325‑2R4‑2A Dual Relay Module 2 A
Provides 2 A current at two
Order number
FLM‑325‑2R4‑2AI Dual Relay Module 2 A with Isolator
Provides 2 A current with
Order number
FLM‑325‑2R4‑8A Dual Relay Module 8 A
Provides 8 A current at two
Order number
FLM‑325‑2R4‑8AI Dual Relay Module 8 A with Isolator
Provides 8 A current with
Order number
FLM‑325‑CZM4 Conventional Zone Module
Enables the FACP to interface and monitor up to 25 conventional devices depending on the device type such as two‑wire smoke detectors or pull stations
Order number
FLM‑325‑I4 Contact Monitor 4‑inch
Mounted to a cover plate for a 4‑inch square or double gang electrical back box; a bi‑colored LED provides module status; compatible with 127 addresses
Order number
Can be wired for Class A or Class B circuits; mounted to a cover plate for a 4‑inch square or double gang electrical back box; bi‑colored LED provides module status; compatible with 254 addresses
Order number
Can be wired for Class A or Class B circuits; has built‑in short circuit isolator circuitry; mounted to a cover plate for a 4‑inch square or double gang electrical back box; bi‑colored LED provides module status; compatible with 254 addresses
Order number
FLM‑325‑IM Contact Module
Allows compatible fire alarm control panels (FACP) to supervise Form A or B dry contact devices in a polling circuit
Order number
FLM‑325‑ISO Short Circuit Isolator
Isolates a shorted section on a specific polling circuit from the rest of the system to minimize the loss of communication
Order number
FMM‑325A Single‑action Manual Station
Communicates with the FPA‑1000 Analog Addressable Fire Panels, D9024, D8024, and D10024A FACPs (both power and data) over a two‑wire polling circuit
Order number
FMM‑325A‑D Double‑action Manual Station
Communicates with the FPA‑1000 Analog Addressable Fire Panels, D9024, D8024, and D10024A FACPs (both power and data) over a two‑wire polling circuit
Order number
FMR‑1000‑RA Remote Annunciator
LCD annunciator without system control capability for use with the FPA‑1000 Analog Addressable Fire Panels
Order number
FMR‑1000‑RCMD Remote Command Center
LCD annunciator with system control capability for use with FPA‑1000 Analog Addressable fire Panels
Order number
FPE‑1000‑CITY City Tie Plug‑in Module
Provides the FPA‑1000 Analog Addressable Fire Panels with two supervised City Tie Local Energy circuits or Reverse Polarity circuits
Order number
FPE‑1000‑NE Networking Card 3‑Ethermet
Ethernet Networking Card for peer‑to‑peer communication in an FPA‑1000‑V2 networked system
Order number
FPE‑1000‑NF Networking Card 1‑Ethernet 2‑Fiber Optic
Fiber Optic Networking Card for peer‑to‑peer communication in an FPA‑1000 networked system
Order number
FPE‑1000‑NW Networking Card 1‑Ethernet 2‑Wired
Wired Networking Card for peer‑to‑peer communication in an FPA‑1000 networked system
Order number
FPE‑1000‑SLC Signaling Line Circuit Plug‑in Module
Provides a Signaling Line Circuit (SLC) for connection of analog devices to the FPA‑1000 Analog Addressable Fire Panels
Order number
FPM‑1000‑ENC Enclosure with Dead Front Door
Enclosure with dead front door
Order number
The
Order number