C. Wiring

 

 

 

 

Amps

Model

Description

Voltage

Watts

(120/208/240)

SILH30E-B

26 in. fi replace/insert

120

1500

12.5

Note: This heater must be electrically wired and grounded in accordance with local codes or, in the absence of local codes, with National Electric Code ANSI/NFPA 70-latest edition or the Canadian Electric Code, CSA C2.1 as appropriate.

All wiring must be done by a qualified electrician. Use appropriate wire to meet local and national codes for rated power consumption.

WARNING

Shock Risk

Improperly grounded outlets could cause electrical shock.

Always use properly grounded, fused and polarized outlets.

Always used ground fault protection where required by electrical code.

CAUTION

Disconnect remote controls during your extended absence. This will prevent accidental operation of the heater.

CAUTION

 

For ease of electrical hook up, you may wish to install the

 

 

 

 

Label all wires prior to disconnection when servicing

 

 

heater near an existing outlet. A 15 amp, 120 volt circuit

controls. Wiring errors can cause improper and dangerous

 

 

is required.

operation. Verify proper operation after servicing.

 

Run the cord out the notch of the front face.

 

 

Before plugging the heater into the wall outlet, make sure

• A dedicated circuit is preferred but not essential in￿

the control switch is in the “OFF” position.

If the cord does not reach the outlet, a No. 16-AWG

all cases. A dedicated circuit will be required if, after

 

minimum wire size extension cord rated for a minimum

installation, the circuit trips or fuse blows on a regular

 

of 1875 watts may be used. Use minimum length and do

basis when the heater is operated. Additional appliances

 

not coil cord.

on the same circuit may exceed the current rating of the

If installing inside a pre-existing fi replace and if permitted

circuit breaker.

 

by local codes, an electrician may install an outlet box

• The heater is wired from the factory with a polarized plug.

 

inside the existing fi replace. Place the outlet in the lower

No provisions have been made for hardwiring.

 

back of the fi rebox.

Heatilator • SILH30E-B4038-896 Rev C • 11/05

11

Image 11
Contents SILH30E-B Listing Label Information/Location Homeowner Reference InformationTable of Contents Not intended for use as a primary heat source Listing and Code ApprovalsCertification Important InstructionsTools and Supplies Needed Getting StartedElectrocution Risk Framing and ClearancesSelecting Heater Location ClearancesModel Framing the Heater Frame the HeaterShock Risk Fire Risk InstallationAs a Fireplace Shock RiskAs an Insert Pre-installation PreparationWiring RW RT Install other Optional Accessories AccessoriesInstall the Front Face Mantel Finishing ChecklistFinishing Finishing MaterialThermostat Main Power SwitchOperating Instructions Troubleshooting Guide TroubleshootingClean the Back Acrylic Panel Maintenance and ServiceAccess the Firebox Clean the Firebox CompartmentWhen cleaning glass door Maintenance Task ListReference Materials Heater DimensionsSST = Stainless Steel Trim Optional ComponentsPBT = Polished Brass Trim SILH30E-B Service Parts# Description of Part Hearth Assembly Ember BedLog Assembly Thermostat Control AssemblyLimited Warranty WarrantyContact Information

SILH30E-B specifications

Hearth and Home Technologies SILH30E-B is an innovative direct vent gas fireplace that combines modern aesthetics with advanced functionality, making it an ideal choice for homeowners who seek both beauty and efficiency. This stylish unit features a sleek design with a large glass front, allowing for an unobstructed view of the flames. The SILH30E-B effortlessly blends into various interior settings, from contemporary to traditional, enhancing the overall ambiance of any room.

One of the standout features of the SILH30E-B is its energy efficiency. This fireplace is designed to maximize heat output while minimizing energy consumption, making it an environmentally friendly choice for heating spaces. The direct vent technology allows the unit to draw air from the outside for combustion, ensuring that the indoor air quality remains unaffected while providing optimal heating performance. This system also eliminates the need for a traditional chimney, simplifying installation and maintenance.

The SILH30E-B boasts a range of customizable options. Homeowners can select from various media types, including glass and stones, to personalize the fireplace's appearance. Additionally, the adjustable flame height feature allows users to create the perfect ambiance, whether they prefer a cozy fire for intimate gatherings or a roaring flame to warm up the entire space. This unit also includes a programmable remote control, granting easy access to the fireplace's settings from anywhere in the room.

Safety is a top priority for Hearth and Home Technologies, and the SILH30E-B incorporates several safety features. The unit is equipped with an automatic shut-off system that activates in case of irregularities, ensuring peace of mind for users. The cool-to-the-touch glass front prevents accidental burns, making it a suitable option for homes with children or pets.

In terms of installation, the SILH30E-B is designed for versatility. It can be installed as a built-in unit or as a zero-clearance fireplace, accommodating various architectural layouts and personal preferences. Its high-quality construction materials and advanced technologies further contribute to its durability and longevity, assuring homeowners of a sound investment.

In summary, the Hearth and Home Technologies SILH30E-B symbolizes the perfect merger of style, efficiency, and safety. With its modern design, customizable features, and energy-efficient performance, it stands out as a leading option for those looking to enhance their living spaces with a reliable and beautiful fireplace solution.