6 Framing & Clearances
A. Select Fireplace Location
G |
F |
A
B
In an exterior chase
H
I
Note: 1/2 in. (13 mm) min. air space from fireplace to combustible materials.
Note: In addition to these framing dimensions, also reference the
E
A Across a C corner
H
or projecting into a garage
following sections:
•Clearances (Section 6.B.)
•Mantel Projections (Section 11.E.)
•Fireplace Dimensions (Section 13.A.)
As a room divider
D A
48 in.
(1219 mm)
minimum
Along a wall | I |
| |
B |
|
A |
|
H
5/8 in. (16 mm) all configurations
Note: Measurements are FRAMING dimensions only and do not include drywall either in the cavity or on the interior walls.
Model | A | B | C | D | E | F | G | H | I | ||
EL36 | inches | 42 | 50 | 67 7/8 | 59 1/2 | 34 | 14 | 48 | 21 1/2 | 12 in. (305 mm) | |
|
|
|
|
|
|
|
|
| Minimum from FP | ||
mm | 1067 | 1270 | 1724 | 1511 | 864 | 356 | 1219 | 546 | |||
| |||||||||||
| opening to any | ||||||||||
| inches | 48 | 56 | 73 7/8 | 65 1/2 | 37 1/4 | 14 | 52 1/4 | 21 1/2 | ||
EL42 | perpendicular wall. | ||||||||||
mm | 1219 | 1422 | 1876 | 1664 | 946 | 356 | 1327 | 546 |
| ||
|
|
Figure 6.1 Fireplace Locations (Framing dimensions shown)
18 | Heatilator • EL36/EL42 • |