Hearth and Home Technologies EL36 Series, EL42 Series owner manual Troubleshooting Guide

Page 13

4 Troubleshooting Guide

Start Fire Problems

Possible Cause

Solution

Can’t get fire started

Not enough kindling/paper or no

Use dry kindling, more paper. Arrange kindling &

Excessive smoke or spillage

kindling/paper

wood for air movement.

Burns too slowly

 

 

Damper closed/not fully open

Open damper.

Smolders, sizzles

 

 

 

Not enough air for fire to ignite

Check for restricted cap/shroud.

 

 

 

 

 

Open air kit (if installed).

 

 

 

 

 

Check for flue blockage.

 

 

 

 

 

Pre-warm flue before starting fire (refer to starting

 

 

fire section).

 

 

 

 

 

Check for adequate vent height (refer to chimney

 

 

assembly section).

 

 

 

 

 

Open window below the fireplace towards the

 

 

wind.

 

 

 

 

Wood condition is too wet, too

Use dry, seasoned wood (refer to wood fuel

 

large

section).

 

 

 

 

Bed of coals not established

Start with paper & kindling to establish bed of

 

before adding wood

coals (refer to starting fire section).

 

 

 

 

Flue blockage such as birds’

Have chimney inspected for creosote and cleaned

 

nests or leaves in termination

by a certified chimney sweep.

 

cap

 

 

 

 

 

Down draft or negative pressure

Do not use exhaust fans during start-up (refer to

 

Competition with exhaust

negative pressure section).

 

devices

 

 

Open window below the fireplace towards the

 

 

 

 

wind.

 

 

 

Fire burns too fast

Extremely dry or soft wood

Mix in hardwood.

 

 

 

 

 

Mix in less seasoned wood after fire is established

 

 

(refer to wood fuel section).

 

 

 

 

No glass doors

Add glass doors to slow down air flow.

 

 

 

 

Overdrafting

Check for correct vent height; too much vertical

 

 

height creates overdrafting.

 

 

 

 

 

Check location of vent termination (refer to

 

 

chimney assembly section).

 

 

 

Heatilator • EL36/EL42 • 4044-132 • Rev V • 11/08

13

Image 13
Contents Operation Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Fire RiskGrate Listing Label Information/LocationNumber Installer Guide Table of ContentsUser Guide CONDITIONS, Exclusions & Limitation of Liability Warranty Hearth & Home Technologies Limited WarrantyHeatilator EL36/EL42 4044-132 Rev V 11/08 Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsYour Fireplace Operating InstructionsHot glass will cause burns Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceWood Fuel Chimney Inspection/Cleaning Maintainance and ServiceDisposal of Ashes Creosote Formation and Need for RemovalCheck Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideGetting Started Installer GuideDraft Design and Installation ConsiderationsNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyFireplace System Requirements Tools and Supplies NeededInspect Fireplace and Components Framing & Clearances Mm all configurationsSelect Fireplace Location Clearances to Combustible Materials ClearancesSidewalls/Surrounds Fireplace Outside Model # Opening DimensionsFrame the Fireplace Things to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsYES Ft min. from top of uppermost chimney section to air inletOutside Air Installation Install Outside Air KitMaintain minimum height of chimney above roof Chimney AssemblyHeight of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssemble Chimney Sections Install Chimney Air KitInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldInstall Flashing Complete InstallationFollowing steps should be skipped if using a chase Cut out Hole in RoofFlat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsGas line holes and other openings should be caulked with Chase should be constructed in the manner of allInstall Chase Top Install Fireplace & ChimneyInstall as per Sections 7 ST375 Square Termination Cap Install Termination CapTCT375 Terra Cotta Cap TS345/TS345P Square Termination CapRadiation Shield ShroudsField Constructed Shrouds Open Top Shroud TR342 caps require radiation shieldRoofed Style Shroud radiation shield required Mailbox Style Shroud radiation shield requiredHearth Extension Finishing= 1/k x inches of thickness Refer to .2 for hearth extension insulation alternativesMinimum between Raised Hearth Extension FramingNoncombustible Finishing Materials Non-combustible SealantIn. Micore or equivilent insulation Finishing MaterialClearances to Mantels or other Combustibles above Fireplace Combustible MantelModel Outside Di- mensionsGas Log/Lighter Provision AccessoriesWood Burning Inserts Gas Code, Ansi Z223.1Reference Materials Fireplace Dimensions1676 mm 508 mm 13 mm 1321 mm 406 mmID4 Insulated Duct Mm i.d 1067 mm UD4 Uninsulated Duct Air Kit PartsCatalog # Chimney Components10-1/2 267 mm Effective Outside Height Diameter 10-1/2 121 mm 267 mm305 mm 27-3/8 24-5/8 695 mm 625 mm 305 mm 24-5/8 625 mm 787 mm10-7/8 276 mm Heatilator EL36/EL42 Service PartsRev V 11/08 EL42 Contact Information